R-49 attic insulation is recommended for this climate, and I spec R-60 for most attic floors because cellulose is cheap.  Yet my own unconditioned attic has an effective R-value of only about 20.  There is a typically settled loose-fill cellulose job from the early 80s under the floorboards.  I decided to relocate the thermal boundary to the top of the loose tongue-and-groove attic floorboards and to the perimeter of the attic floor plane, creating in effect an inverted, insulated box over the living space. I added 2” of extruded polystyrene board and covered it with OSB.  There is no condensing surface inside my inverted box.

 

      I paid special attention to the exterior top plates and (perhaps most importantly) I personally attended to or oversaw every detail.  This led me back to the inescapable truth is that attention to workmanship is the key to building performance

 

 

Views: 75

Comment

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

Comment by Joseph J. Ilacqua on February 23, 2011 at 9:12am
Geez, I wonder who insulated the walls on that house, Chris is taking credit for the attic, my memory isn't quite as sharp as it used to be, i can't remember

Videos

  • Add Videos
  • View All

Twitter

Latest Activity

Ed Minch commented on Tom White's video
Thumbnail

Measured Home Performance: Assessment with a Infrared Camera

"I find it best to scan one time before the Blower Door is used to check for insulation and…"
yesterday
Profile IconLarry Kinney and teplie_poly joined Home Energy Pros
yesterday
Dan Antonioli replied to Dan Antonioli's discussion Net Zero Energy Hot Water
"Okay, a couple of things. The 1.0 kW per square meter reference is only under the most ideal lab…"
Saturday
Hans Joachim Preiss replied to Dan Antonioli's discussion Net Zero Energy Hot Water
"Dan, Let me attempt to compare apples with apples: My solar thermal system is located in…"
Friday
Dan Antonioli replied to Dan Antonioli's discussion Net Zero Energy Hot Water
"Hi Hans, I don't know where you're located but where I am a 2.5 kw pv system costs closer…"
Friday
Hans Joachim Preiss replied to Dan Antonioli's discussion Net Zero Energy Hot Water
"I use the combination of solar PV and heatpump water heaters in the vast majority of net-zero…"
Friday
Amber Vignieri posted a blog post
Friday
William Zwack added a discussion to the group Job Board
Thumbnail

Residental Energy Specialist: Washington, DC (or possibly telework)

Position Summary: CSRA Incorporated is searching for a Sr. Residential Building Energy Efficiency…See More
Friday

© 2016   Created by Lawrence Berkeley National Laboratory.   Powered by

Badges  |  Report an Issue  |  Terms of Service