R-49 attic insulation is recommended for this climate, and I spec R-60 for most attic floors because cellulose is cheap.  Yet my own unconditioned attic has an effective R-value of only about 20.  There is a typically settled loose-fill cellulose job from the early 80s under the floorboards.  I decided to relocate the thermal boundary to the top of the loose tongue-and-groove attic floorboards and to the perimeter of the attic floor plane, creating in effect an inverted, insulated box over the living space. I added 2” of extruded polystyrene board and covered it with OSB.  There is no condensing surface inside my inverted box.

 

      I paid special attention to the exterior top plates and (perhaps most importantly) I personally attended to or oversaw every detail.  This led me back to the inescapable truth is that attention to workmanship is the key to building performance

 

 

Views: 77

Comment

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

Comment by Joseph J. Ilacqua on February 23, 2011 at 9:12am
Geez, I wonder who insulated the walls on that house, Chris is taking credit for the attic, my memory isn't quite as sharp as it used to be, i can't remember

Videos

  • Add Videos
  • View All

Twitter

Latest Activity

Jim Gunshinan liked Tom White's discussion Home Energy Reader Survey
3 hours ago
Tom White posted a discussion

Home Energy Reader Survey

Home Energy wants to serve you better.  Please …See More
yesterday
George Matthews's event was featured

Proof is Possible Tour by the Home Performance Workshop at Truitt and White Lumber Conference Room

October 7, 2016 from 9am to 1pm
Building Energy Performance Testing is sponsoring the Proof is Possible Tour to come to the San…See More
yesterday
Profile IconAshley Noreuil, Fred Smith and Peter Moncada joined Home Energy Pros
yesterday
George Matthews commented on George Matthews's event Proof is Possible Tour by the Home Performance Workshop
"Here is the flyer for the Advanced Techniques and Tools in Home Performance Friday October 7th at…"
yesterday
George Matthews posted an event

Proof is Possible Tour by the Home Performance Workshop at Truitt and White Lumber Conference Room

October 7, 2016 from 9am to 1pm
Building Energy Performance Testing is sponsoring the Proof is Possible Tour to come to the San…See More
yesterday
George Matthews replied to George Matthews's discussion Shortridge 8400 Flowhood for A/C airflow testing in the group Energy Auditing Equipment for Sale, Trade or to Purchase
"Here are the pics of the flowhood and airdata manometer"
Saturday
Sarah Holloway posted a photo
Friday

© 2016   Created by Lawrence Berkeley National Laboratory.   Powered by

Badges  |  Report an Issue  |  Terms of Service