air sealing sprinklers

Started this discussion. Last reply by Ed Minch May 28, 2013. 8 Replies

does anyone have experience air sealing fire sprinklers? Per California code, all new  homes must have fire sprinklers.... think 30 to 40 holes in the ceiling. Per installer, you can't foam/caulk the…Continue

 

mike keesee's Page

Latest Activity

Ed Minch replied to mike keesee's discussion air sealing sprinklers
"Great document - however they give short shrift to my preferred recommendation which is to install wall heads - get ALL the pipes out of the attic.  I don't care how well you do the "tenting", I can still see the path of the…"
May 28, 2013
mike keesee replied to mike keesee's discussion air sealing sprinklers
"Great.  How timely is this!  and I'm on a BA team.  Thanks."
May 16, 2013
Wes Harding replied to mike keesee's discussion air sealing sprinklers
"Check out this study from DOE: http://www.nrel.gov/docs/fy13osti/56667.pdf Wes "
May 16, 2013
mike keesee's discussion was featured

air sealing sprinklers

does anyone have experience air sealing fire sprinklers? Per California code, all new  homes must have fire sprinklers.... think 30 to 40 holes in the ceiling. Per installer, you can't foam/caulk the sprinkler as this will make it inoperable or void the warranty. Any ideas?See More
May 15, 2013
Sean Lintow Sr replied to mike keesee's discussion air sealing sprinklers
"My pleasure & let me just quickly state - being in Cali with the new Title 32 (?) stuff coming out, he might find it cheaper & easier - definitely worth giving it a shot "
May 14, 2013
mike keesee replied to mike keesee's discussion air sealing sprinklers
"Sean,  Thanks for clarifing... I didn't know that "hot roof assembly" referred to conditioned attics.  Unfortunately that won't work with this builder.  The builder is a medium size production builder who is not…"
May 14, 2013
Sean Lintow Sr replied to mike keesee's discussion air sealing sprinklers
"Sorry, you asked for suggestions & the best one is to go with a hot roof assembly (http://bit.ly/HotRoof) I would simply ask the installer for the manufacturer & model info if they don't have the specs handy. With that you can…"
May 14, 2013
mike keesee replied to mike keesee's discussion air sealing sprinklers
"Sean,  Thanks for the suggestion, but just to confirm, the manufacturer is hot roof assembly?  please verify.  Thanks."
May 14, 2013
Sean Lintow Sr replied to mike keesee's discussion air sealing sprinklers
"Yep its called a hot roof assembly I would check the manufacturers directions / website but you will probably end up using something like tenmat covers over them"
May 13, 2013
mike keesee posted a discussion

air sealing sprinklers

does anyone have experience air sealing fire sprinklers? Per California code, all new  homes must have fire sprinklers.... think 30 to 40 holes in the ceiling. Per installer, you can't foam/caulk the sprinkler as this will make it inoperable or void the warranty. Any ideas?See More
May 13, 2013
Linda Wigington left a comment for mike keesee
"Mike -  Do you have any end-use monitiring data with ductless heat pumps?   Linda"
Sep 30, 2011
David Eggleton left a comment for mike keesee
"Welcome to the 1000 Home Challenge group, Mike.  As the project moves out from the pilot phase, much of interest will emerge!  At any time, send me nominations for the Resources section of the group's page."
Sep 23, 2011
mike keesee joined David Eggleton's group
Thumbnail

1000 Home Challenge

Linda Wigington distinguished between deep retrofits & deep energy reductions, thus expanding the range of strategies & tactics from which we might propose when engaging with people, the ones who choose.See More
Sep 6, 2011
Linda Wigington left a comment for mike keesee
"Hi Mike -   Do you have any hot weather DHP data to add?    http://homeenergypros.lbl.gov/group/1000homechallenge/forum/topics/hot-weather-ductless-heat-pump-performance   Linda"
Aug 29, 2011
mike keesee is now a member of Home Energy Pros
Aug 22, 2011

Profile Information

Company
SMUD

Comment Wall (4 comments)

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

At 8:09am on September 30, 2011, Linda Wigington said…

Mike -

 Do you have any end-use monitiring data with ductless heat pumps?

 

Linda

At 1:06pm on September 23, 2011, David Eggleton said…
Welcome to the 1000 Home Challenge group, Mike.  As the project moves out from the pilot phase, much of interest will emerge!  At any time, send me nominations for the Resources section of the group's page.
At 2:30pm on August 29, 2011, Linda Wigington said…
At 11:33am on August 22, 2011, Diane Chojnowski said…

Hi Mike,

Welcome to Home Energy Pros! Feel free to join the conversation in the Forum and Groups. And share your energy efficiency photos, videos and upcoming events. If you're blogging about home performance, this is the place for you!

Don't forget to upload your profile photo. And add your location on our Member Map!


Thanks!
Diane, HEP Moderator

 
 
 

Videos

  • Add Videos
  • View All

Twitter

Latest Activity

Therma-HEXX posted a blog post

The ABCs of Snowmelting

Read this great article about snowmelting systems …See More
46 minutes ago
Rich Manning commented on Amber Vignieri's blog post Elevate Energy Mythbusters: Windows & Attics Edition
"Amber, Good blog, but heat does not rise. Heat always goes to cold. Hot air rises! "
1 hour ago
Joseph Schulman posted a status
"hello"
2 hours ago
David Baerg joined allen p tanner's group
Thumbnail

Energy Auditing Equipment for Sale, Trade or to Purchase

Discuss the pros and cons of the equipment you are interested in prior to purchase. Post equipment…See More
3 hours ago
Jan Green replied to Jan Green's discussion Retrofitting a 1979 Home to NAHB Silver or Gold - Pending Cert
"Nice meeting you as well Tom!  You're right! My last 2 electric bills have been $39 and…"
4 hours ago
Steve Mann added a discussion to the group Energy Auditing Equipment for Sale, Trade or to Purchase
Thumbnail

Energy Conservatory FlowBlaster

I've got a relatively new Energy Conservatory FlowBlaster for sale. Excellent condition. Hardly…See More
5 hours ago
Michael D'Arcy replied to Michael D'Arcy's discussion Small video we created to promote Home Performance
"Hello Tedkidd, Of course I track these. I actually see more savings often per project then $700…"
5 hours ago
tedkidd replied to Michael D'Arcy's discussion Small video we created to promote Home Performance
""Average savings $700" "Helps you avoid deciding between energy bills, and…"
7 hours ago

© 2016   Created by Lawrence Berkeley National Laboratory.   Powered by

Badges  |  Report an Issue  |  Terms of Service