Section 403.2.2 of the 2009 IECC
11 Replies

We've received a lot of calls of (panicked) HVAC contractors on this new code requiring duct leakage testing. Can anyone shed some light on this?  Do the requirements vary state - state?  Can anyone…Continue

Tags: code, testing, leakage, duct

Started this discussion. Last reply by Bob Blanchette Mar 22, 2012.

So have you experienced the New TEC Trainer?

Just curious if any trainers/students have experienced the new TEC Trainer form The Energy Conservatory. If so, we'd loved to hear feedback!…Continue

Tags: energy, pressurize, blower, door, duct

Started Jan 26, 2012

 

Tracy & Matt's Page

Latest Activity

Guy DuBois left a comment for Tracy & Matt
"Great to know you "guys"! (Sorry Tracy, that's the way slang works sometimes!)"
Mar 25, 2013
Tracy & Matt replied to Tracy & Matt's discussion Does a professional Multifamily Market Study exist? in the group Multifamily Buildings
"This is great.  Thank you Tom!"
Jan 2, 2013
Tom Conlon replied to Tracy & Matt's discussion Does a professional Multifamily Market Study exist? in the group Multifamily Buildings
"Although focused primarily on California, we've posted a number of multifamily technical reports, case studies, and videos that I hope you will find useful: http://energydesignresources.com/buildings/homes.aspx In addition, you can also try…"
Dec 27, 2012
Tracy & Matt replied to Tracy & Matt's discussion Does a professional Multifamily Market Study exist? in the group Multifamily Buildings
"Thanks Matthew! "
Dec 6, 2012
Matthew Redmond replied to Tracy & Matt's discussion Does a professional Multifamily Market Study exist? in the group Multifamily Buildings
"Tracy/Matt, Welcome. I believe that here in NY that NYSERDA has done several studies. I have not seen them but you can go to nyserda.org and go to the multifamily program and see what you can dig up......"
Dec 6, 2012
Tracy & Matt added a discussion to the group Multifamily Buildings
Thumbnail

Does a professional Multifamily Market Study exist?

Does anyone know of professional MARKET STUDY results to assess the demand for home performance, weatherization or other related services for multifamily buildings?  Please advise if you can offer any information regarding existing market studies and/or resources that might be engaged to conduct such a study of our target markets (Virginia and/or mid-Atlantic region).  If so can you share below or email or contact us?CSOrders@ConservationStrategies.com804-525-7655800-989-6686Thanks!Tracy &…See More
Dec 6, 2012
Tracy & Matt joined Norm Bourassa's group
Thumbnail

Multifamily Buildings

For too long there has been relatively little EE focus on multifamily, but some new programs have recently started. This group gives us a venue to share our experiences on cost effective audit & retrofit strategies and analysis tool needs.See More
Dec 6, 2012
Tracy & Matt replied to Tracy & Matt's discussion Gently Used Blower Door & Duct Blaster Now at a Discount! in the group Energy Auditing Equipment for Sale, Trade or to Purchase
"We are Matt and thanks so much for the heads up!  We have IT looking into it but in the meantime you should be able to reach me 804-612-3352 Tracy"
Nov 2, 2012
Matt replied to Tracy & Matt's discussion Gently Used Blower Door & Duct Blaster Now at a Discount! in the group Energy Auditing Equipment for Sale, Trade or to Purchase
"Are you still in operation, your 800 phone produces a "not in service at this time" response."
Nov 2, 2012
Tracy & Matt replied to Tracy & Matt's discussion Gently Used Blower Door & Duct Blaster Now at a Discount! in the group Energy Auditing Equipment for Sale, Trade or to Purchase
"Please note both discounted units have been sold! We do carry a full line of The Energy Conservatory products, and more, at great prices...Just give me a call! Thanks, Tracy Conservation Strategies 1-800-989-6686"
Aug 7, 2012
Tracy & Matt replied to Dan Antonioli's discussion Wooden Plugs For 2" Insulation Holes
"Hello Dan.  We carry  Pine Plugs in the 2" size.  Our non-profit's weatherization crews use with no issues of sizing.  You can order online or call me. Tracy 1-800-989-6686 "
Apr 19, 2012
Tracy & Matt commented on Diane Chojnowski's group Facebook Pages
"@Johnny - I'm not a big fan of the timeline layout as the posts and other updates seem cluttered but I do love the large cover photo as I like to use it to highlight specials or new products.  I just created an cover image to feature a…"
Apr 12, 2012
Bob Blanchette replied to Tracy & Matt's discussion Section 403.2.2 of the 2009 IECC
"Glued joints on PVC pipe would be more "idiot-proof" vs metal/flex than needs to be taped/mastic to be effectively sealed. Take offs could be 45 degree Wye connectors, no different than used with metal ductwork designs. The real key would…"
Mar 22, 2012
John Nicholas replied to Tracy & Matt's discussion Section 403.2.2 of the 2009 IECC
"Bob, The issue is not the product. The issue is the installation.  I've seen holes in ducts, and those holes would be there in PVC, if it were used for ducts.  Someone would incompletely glue a joint, and air would leak!  As for…"
Mar 22, 2012
Tracy & Matt added a discussion to the group Energy Auditing Equipment for Sale, trade or to purchase
Thumbnail

Gently Used Blower Door & Duct Blaster Now at a Discount!

These items were probably never used.  They sat in a Community College warehouse for 9 months, and had to be returned because of bureaucratic budget technicalities.  We sent the equipment back to The Energy Conservatory for inspection and recalibration.  Everything checked out fine.Standard Model 3 Minneapolis Blower Door system which includes:Fan with variable speed controller and fan control cable.Two Flow Rings (A and B) and No Flow Plate.DG-700 Pressure and Flow GaugeTECTITE™ Building…See More
Mar 20, 2012
Bob Blanchette replied to Tracy & Matt's discussion Section 403.2.2 of the 2009 IECC
"Why not use PVC pipe for ductwork? It would be water tight, zero air leakage. With tight building construction, you could put a 4" duct where a conventional system would have needed a 6". Since pipes would be smaller they would be easier…"
Mar 10, 2012

Profile Information

Company
Conservation Strategies
Professional Interests
Energy Conservation Products & Services, Weatherization
Website URL
http://www.conservationstrategies.com
Blog URL
http://cscwx.blogspot.com/
Twitter ID
ConservationStr
Facebook Page
https://www.facebook.com/conservationstrategies
LinkedIn Profile
http://www.linkedin.com/company/conservation-strategies-inc.

Tracy & Matt's Photos

Loading…
  • Add Photos
  • View All

Comment Wall (2 comments)

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

At 1:19pm on March 25, 2013, Guy DuBois said…

Great to know you "guys"! (Sorry Tracy, that's the way slang works sometimes!)

At 7:23am on November 5, 2011, Diane Chojnowski said…

Hi Tracy & Matt,

Welcome to Home Energy Pros! Feel free to join the conversation in the Forum and Groups. And share your energy efficiency photos, videos and upcoming events. If you're blogging about home performance, this is the place for you!

Don't forget to upload your profile photo. And add your location on our Member Map!


Thanks!
Diane, HEP Moderator

 
 
 

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.

Latest Activity

Jim Gunshinan posted blog posts
11 hours ago
H.O. Electric posted a photo

about us-team

H.O. Services is your residential Electric-Plumbing-Heating-Cooling Specialist. We are an…
12 hours ago
H.O. Electric added a discussion to the group News & Announcements
Thumbnail

Stay Cool With Easy To Install Ductless AC System!

Stay Cool With Easy To Install Ductless AC System!   Save $300.00 Off A New AC System For A Limited…See More
12 hours ago
Richard Wells commented on Diane Chojnowski's group Facebook Pages
"Three thousand home energy efficiency audits, and nearly a thousand retrofits in four short…"
13 hours ago
Richard Wells joined Diane Chojnowski's group
Thumbnail

Facebook Pages

Does your company or organization have a Facebook Page?This group is for pros who have facebook…See More
13 hours ago
David Baerg replied to Blake Shurtz's discussion Air sealing wood-burning fireplace from the crawlspace below
"Hi Blake, Do you mean around the underside of the hearth?  Are you trying to seal between the…"
14 hours ago
Tom White's video was featured

Rebirth Realty: Restoring Detroit properties for Venture for America Fellows

Its been a long, cold winter, but we've made significant progress in the restoration of 760 Virginia Park. Join Tim Dingman on a walkthrough to see what we've done.
15 hours ago
Kim Tanner added a discussion to the group Multifamily Buildings
Thumbnail

Blower Door Applications Guide

TEC and Camroden Associates have released their big building testing manual, Blower Door…See More
15 hours ago
Profile Iconmichael coleman, Dan Liska and Rob Moreno joined Home Energy Pros
16 hours ago
Christopher Morin's blog post was featured

5 Things New Energy Efficiency HVAC Contractors Need to Know

1. Do not sell on Price! Use 'Simple Payback'The price of High-efficient equipment will undoubtedly…See More
yesterday
Jim Gunshinan's blog post was featured
yesterday
Kim Tanner commented on Diane Chojnowski's group Home Energy Pros on Twitter
"Follow The Energy Conservatory on Twitter! We'll follow…"
yesterday

© 2014   Created by Lawrence Berkeley National Laboratory.

Badges  |  Report an Issue  |  Terms of Service