Paul Stevens's Discussions

Peak Energy Saver
21 Replies

Is any one familiar with the Peak Energy Saver from www.peakenergytech.com  The unit is intended to store energy from motors used in the home and then…Continue

Started this discussion. Last reply by Bob Blanchette Jan 16.

 

Paul Stevens's Page

Latest Activity

Bob Blanchette replied to Paul Stevens's discussion Peak Energy Saver
"4 out of 400K? All 4 are most likely large industrial customers with 3 phase power. There is absolutely no reason for any residential customer to be concerned about this. I've never seen/heard of any time of PF charge on single phase power."
Jan 16
Curt Kinder replied to Paul Stevens's discussion Peak Energy Saver
"Well, I work with the conservation guys at a big local electric utility. One of them told me, by way of agreeing that residential power factor correction is a complete scam, that out of their 400,000 (yes - four hundred thousand) electric customers,…"
Jan 16
Planet Man replied to Paul Stevens's discussion Peak Energy Saver
"I like your phrase horsefeathers though here in the UK we may say rockin' horse dung!.... joking aside though I can only vouch for how industrial 3phase sites are billed here, the US may be different billing. So installing PFC equipment will…"
Jan 15
Curt Kinder replied to Paul Stevens's discussion Peak Energy Saver
"Horsefeathers! Improving a building or plant's power factor does NOTHING for individual motors. I sincerely hope you are not hawking your views for personal gain."
Jan 14
Planet Man replied to Paul Stevens's discussion Peak Energy Saver
"Unfortuantely that is not the whole picture. Granted billing is in KW however improving power factor will have a saving as motors will now be operating optimally hence be more efficent so last longer with less maintenance. Because also KVA is closer…"
Jan 13
Curt Kinder replied to Paul Stevens's discussion Peak Energy Saver
"Power Factor Correction is ONLY worth considering for electricity users who are penalized (billed) for inadequate power factor by the utility. All others are billed for kW, not KVA, so it is a complete waste of money for all others to fall prey to…"
Jan 13
Planet Man replied to Paul Stevens's discussion Peak Energy Saver
"Power factor correction is old, well established technnlogy which is widely used across industry and larger electricity power users. However this technology is used to reduce wasted power to bring KVA closer to KW and is not used for the above…"
Jan 13
Bob Bruns replied to Paul Stevens's discussion Peak Energy Saver
"Your welcome Fred. Good luck to you."
May 2, 2013
Fred Stratton replied to Paul Stevens's discussion Peak Energy Saver
"Thanks Bob.  This providing me a quick uptake on the whole issue...greatly appreciated! "
May 2, 2013
Bob Bruns replied to Paul Stevens's discussion Peak Energy Saver
"By residential solar, you mean Photo Voltaic I will assume, where the energy from the sun is converted to electric power. The conversion is to DC, direct current, for which power factor is not applicable. There is a second device, called an…"
May 2, 2013
Fred Stratton replied to Paul Stevens's discussion Peak Energy Saver
"I sure as heck agree with all the statements about the deceptive 'pitch' on this kind of device.  Do they have any application in residential solar applications?  Just wondering."
May 2, 2013
Bob Blanchette replied to Paul Stevens's discussion Peak Energy Saver
"Unless your utility bills you for low power factor (I've not seen one that does for residential) this device will save no money. On commercial applications a simple capacitor wired across the motor leads or power line is what is used to correct…"
Apr 28, 2013
Curt Kinder replied to Paul Stevens's discussion Peak Energy Saver
"Joe, You are kidding, right?"
Apr 28, 2013
Joe Romero replied to Paul Stevens's discussion Peak Energy Saver
"It is looking like a good deal, but I am sorry to say that I do not know about this and I am curious to find more about this. Thank you for taking our attention to this. I am going to find out more and will be back here with detail information, but…"
Apr 28, 2013
Bob Bruns replied to Paul Stevens's discussion Peak Energy Saver
"I did see a demo of this system recently. Classic KVAR scam. They claim now that reducing current on the neutral conductor is proof of "recycling" energy. Its a new pitch and they had a few people at their booth. It is only a new variation…"
Apr 27, 2013
Curt Kinder replied to Paul Stevens's discussion Peak Energy Saver
"Likely snake oil Sounds like yet another variation on notorious power factor correction devices"
Apr 25, 2013

Profile Information

Company
Stevens Home Pro Energy Audits
Professional Certification
BPI Analyst, RESNET HESP I & II
Professional Interests
Home energy Audits Floor Covering, County Commissioner
Website URL
http://homeproenergyaudits.com

Comment Wall

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

  • No comments yet!
 
 
 

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.

Latest Activity

Richard Vito joined Sean Lintow Sr's group
Thumbnail

Best Practices (Residential)

Best Building, Retrofitting, or even Auditing Practices - what are they, what should change, what…See More
6 hours ago
Richard Vito joined James Sayers's group
Thumbnail

Marketing Energy Efficiency

Sharing ideas, tools and examples of promoting energy efficiency to consumersSee More
6 hours ago
Richard Vito joined Allison A. Bailes III's group
Thumbnail

HVAC

HVAC design, Manuals J, S, T, & D, Duct leakage, Air flow, ENERGY STAR new home requirements,…See More
6 hours ago
Richard Vito joined Kyle Brown's group
Thumbnail

Wrightsoft - Manual J / Manual D

If you use Wrightsoft to calculate loads or design ducts, you likely have questions.  Get answers…See More
6 hours ago
Richard Vito joined allen p tanner's group
Thumbnail

Energy Auditing Equipment for Sale, Trade or to Purchase

Discuss the pros and cons of the equipment you are interested in prior to purchase. Post equipment…See More
6 hours ago
Jim Gunshinan commented on Jim Gunshinan's blog post Energy Upgrade California—Up Close and Personal
"I had a revelation while attending Bruce Manclark's session of duct leak testing at the Energy…"
20 hours ago
George J. Nesbitt commented on Jim Gunshinan's blog post Energy Upgrade California—Up Close and Personal
"Blower Door; the 2007 test was a depressurization test, and the 2014 a pressurization test, which…"
20 hours ago
George J. Nesbitt replied to Kaushal Bharath Raju's discussion Affordability & Deep Energy Upgrade/Passive House Retrofit in Berkeley, California.
"Plan, plan, plan, plan. The 1st step to is to understand the house, how it's built, the…"
20 hours ago
George J. Nesbitt posted an event

High Performance Windows - A Panel of Experts at Pyramid Alehouse`

April 26, 2014 from 3pm to 5pm
Join a lively panel discussion on high performance windows. We'll cover some basics, as well as…See More
22 hours ago
Kaushal Bharath Raju replied to Kaushal Bharath Raju's discussion Affordability & Deep Energy Upgrade/Passive House Retrofit in Berkeley, California.
"Hi David, Thanks for pointing out Martin Holiday's article. I do not wish to engage in the…"
22 hours ago
Profile IconAdam Penberthy, Scot Davidson and j jarvella joined Home Energy Pros
22 hours ago
David Eakin replied to Kaushal Bharath Raju's discussion Affordability & Deep Energy Upgrade/Passive House Retrofit in Berkeley, California.
"More food for thought on this subject - read this (fairly) recent blog by one of the most respected…"
yesterday

© 2014   Created by Lawrence Berkeley National Laboratory.

Badges  |  Report an Issue  |  Terms of Service