Robert D York Jr replied to Jeff Stuart's discussion Blow machines in the group Weatherization
"Accu 1 makes pretty good machines, 9300 and 9400 can blow cell or fiberglass. Biggest problem that I've had with them is getting voltage drop through cords. Eliminated it by setting up a breaker box inside the truck and running a 10 guage cord…"
Feb 24, 2013
Matthew Redmond replied to Jeff Stuart's discussion Blow machines in the group Weatherization
"I primarily use the Krendl machines. The Krendl 500 works well for both dense pack and open blow. It also handles cellulose and fiberglass. I like the dual blower and the machine is fairly light so two man can move it. For larger high…"
Dec 17, 2012
Jeff Stuart added a discussion to the group Weatherization
Thumbnail

Blow machines

Does anyone have any input on what would be the best weatherization blow machine out there? I would like to have a machine that is primarily used for Retro fit walls and attic, but can also blow fiberglass. I have had PTO diven machines, independant motor machines, but never an electric. I would be interested in hearing feedback.See More
Dec 17, 2012
Jeff Stuart joined Tom White's group
Thumbnail

Weatherization

Share your concerns and successes as a weatherization professional, or information for this community.
Dec 17, 2012

Jeff Stuart just added their location.
(via Member Map)

Dec 3, 2012
Jeff Stuart is now a member of Home Energy Pros
Jan 3, 2011

Profile Information

Company
Alpha Insualtion and Gutters LLC
Professional Certification
BPI certified building analyst, envelope professional

Comment Wall (1 comment)

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

At 3:58pm on January 3, 2011, Diane Chojnowski said…

Hi Jeff,

Welcome to Home Energy Pros! Feel free to join the conversation in the Forum and Groups. And share your energy efficiency photos, videos and upcoming events. If you're blogging about home performance, this is the
place for you!

Don't forget to upload your profile photo. And, add your location on our Member
Map
!

Thanks!
Diane, HEP Moderator

 
 
 

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.  Home Energy Pros is sponsored by the Better Buildings Residential Network.

Latest Activity

Hannah Finch posted a blog post

Want to Lead a Breakout Session at RaterFest! 2015?

We are adding something new to RaterFest! this year... attendee led breakout sessions on Saturday…See More
2 hours ago
Rod Fox replied to Rod Fox's discussion Does calcification affect electric water heater aquastat temperature sensor performance?
"We're in climate zone 5 (near Santa Fe, NM) where it's dry as a bone. Gonna head to that…"
3 hours ago
Bud Poll replied to Rod Fox's discussion Does calcification affect electric water heater aquastat temperature sensor performance?
"The two 4500 watt elements will never operate simultaneously.  It will be one or the…"
4 hours ago
Rod Fox replied to Rod Fox's discussion Does calcification affect electric water heater aquastat temperature sensor performance?
"Correction to this last posting... This model only operates one element at a time, not two in…"
4 hours ago
Rod Fox replied to Rod Fox's discussion Does calcification affect electric water heater aquastat temperature sensor performance?
"Agreed. Incidentally, I just called tech support at Bradford White (and actually spoke to a…"
4 hours ago
Hans Joachim Preiss replied to Rod Fox's discussion Does calcification affect electric water heater aquastat temperature sensor performance?
"Rod, Because the tank is not overheating, the behavior is either normal for this tank or there is a…"
4 hours ago
Rod Fox replied to Rod Fox's discussion Does calcification affect electric water heater aquastat temperature sensor performance?
"Hey thanks Hans. I didn't know about the benefit of the heatpump units having the elements…"
4 hours ago
Rod Fox replied to Rod Fox's discussion Does calcification affect electric water heater aquastat temperature sensor performance?
"I'm not sure if the tank was flushed at the time of element replacement. I would have hoped…"
4 hours ago