Flow Grid suggestions?

Started this discussion. Last reply by Kohta Ueno Jul 16, 2014. 5 Replies

Hi All,I am trying to figure out a good flow grid system to use for testing airflow in 2 to 5 ton forced air systems.Any favorites?Or, if you prefer a flow-hood, please tell my why.The flow hoods…Continue

Tags: tools, hoods, flow

 

George Matthews's Page

Latest Activity

Dan Gwiazdon replied to George Matthews's discussion Shortridge 8400 Flowhood for A/C airflow testing in the group Energy Auditing Equipment for Sale, Trade or to Purchase
"Is the flow hood still for sale? I'm interested. Please email or call me directly. Dan Gwiazdon DanGwiazdon@aol.com (916)856-7709"
Nov 2, 2016
George Matthews's event was featured

Proof is Possible Tour by the Home Performance Workshop at Truitt and White Lumber Conference Room

October 7, 2016 from 9am to 1pm
Building Energy Performance Testing is sponsoring the Proof is Possible Tour to come to the San Francisco Bay Area.Learn about Ventilation testing, advanced leakage quantification, all HVAC airflow tests, delivered Btu tests and infrared thermal photograpsy.All this building energy performance learning for only $99!Truitt and White Lumber, 642 Hearst Ave., Berkeley, CAOctober 7.See More
Sep 26, 2016
George Matthews commented on George Matthews's event Proof is Possible Tour by the Home Performance Workshop
"Here is the flyer for the Advanced Techniques and Tools in Home Performance Friday October 7th at Truitt and White, http://bect.us/wp-content/uploads/2016/03/ProofIsPossibleTour-TrainingDayFlyer-SanFran.pdf George Matthews www.bect.us ;…"
Sep 25, 2016
George Matthews posted an event

Proof is Possible Tour by the Home Performance Workshop at Truitt and White Lumber Conference Room

October 7, 2016 from 9am to 1pm
Building Energy Performance Testing is sponsoring the Proof is Possible Tour to come to the San Francisco Bay Area.Learn about Ventilation testing, advanced leakage quantification, all HVAC airflow tests, delivered Btu tests and infrared thermal photograpsy.All this building energy performance learning for only $99!Truitt and White Lumber, 642 Hearst Ave., Berkeley, CAOctober 7.See More
Sep 25, 2016
George Matthews replied to George Matthews's discussion Shortridge 8400 Flowhood for A/C airflow testing in the group Energy Auditing Equipment for Sale, Trade or to Purchase
"Here are the pics of the flowhood and airdata manometer"
Sep 23, 2016
George Matthews replied to George Matthews's discussion Shortridge 8400 Flowhood for A/C airflow testing in the group Energy Auditing Equipment for Sale, Trade or to Purchase
"For sale, $1500  George Matthews george@bect.us"
Sep 19, 2016
George Matthews added a discussion to the group Energy Auditing Equipment for Sale, Trade or to Purchase
Thumbnail

Shortridge 8400 Flowhood for A/C airflow testing

Used Shortridge 8400 Flowhood to measure the amount of air an air conditioner is blowing. CA energy code requires 350 CFM per ton. This is the device to make sure your job is up to code and working properly. Accurate from 25 to 2500 CFM. It can be used to measure each register and do room by room airflows to match calculations. Also measures Volocity and temperature of air.This is a high quality test apparatus made in the USA. You can buy every part of this unit from the Shortridge factory in…See More
Sep 19, 2016
Kohta Ueno replied to George Matthews's discussion Flow Grid suggestions?
"If you wanted more information on the TrueFlow plate, the manufacturer is offering a webinar on it…"
Jul 16, 2014
George Matthews's discussion was featured

Flow Grid suggestions?

Hi All,I am trying to figure out a good flow grid system to use for testing airflow in 2 to 5 ton forced air systems.Any favorites?Or, if you prefer a flow-hood, please tell my why.The flow hoods I've used take up more space in my vehicle than I would like.Thanks for your thoughts.GeorgeSee More
Jul 14, 2014
Eric Kjelshus replied to George Matthews's discussion Flow Grid suggestions?
"I like the flat true flow plate when it fits-  if not the by pass is very very large.   Or if the presser is to high  its off some.   I have used 4 True flow plates  on a 2 ton spit system to find air flow.  …"
Jul 10, 2014
Kohta Ueno replied to George Matthews's discussion Flow Grid suggestions?
"Assuming that you're mainly interested in the total air handler flow, and you have access to the filter slots, I'd suggest looking at Energy Conservatory's TrueFlow.  It's a flat plate with openings; it has adapter plates…"
Jul 10, 2014
George Matthews replied to George Matthews's discussion Flow Grid suggestions?
"Thanks Eric!"
Jul 9, 2014
Eric Kjelshus replied to George Matthews's discussion Flow Grid suggestions?
"I have 3 hoods - low flow ( 10-500 CFM)  Med flow (40-1500 CFM)  high flow (50-2000CFM) Open grid  for kitchen hoods. Plus hot wire plus presser plus other testing tools.   I test the air flow 3 ways  on each major job just…"
Jul 9, 2014
George Matthews posted a discussion

Flow Grid suggestions?

Hi All,I am trying to figure out a good flow grid system to use for testing airflow in 2 to 5 ton forced air systems.Any favorites?Or, if you prefer a flow-hood, please tell my why.The flow hoods I've used take up more space in my vehicle than I would like.Thanks for your thoughts.GeorgeSee More
Jul 8, 2014
George Matthews replied to Paul Lasicki's discussion Have Equipment for sale (Mendocino County, Ca.) in the group Energy Auditing Equipment for Sale, Trade or to Purchase
"Hi Paul, Do you still have the  Minneapolis Blower door system w/ DG-700 manometer and Minneapolis Duct Blaster for sale? George Matthews geomat77@yahoo.com cell 510 520 4443"
Jun 25, 2014
George Matthews joined allen p tanner's group
Thumbnail

Energy Auditing Equipment for Sale, Trade or to Purchase

Discuss the pros and cons of the equipment you are interested in prior to purchase. Post equipment you have to sell, trade or wish to purchase.Please post the equipment age, serial numbers, condition, warranties and asking price.See More
Jun 25, 2014

Profile Information

Company
Bright Green Strategies
Professional Certification
HERS Rater, BPI Energy Analyst, Single and Multifamily

Comment Wall (1 comment)

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

At 12:47pm on March 21, 2014, Diane Chojnowski said…

Welcome to Home Energy Pros! Feel free to join the conversation in the Forum and Groups. And share your energy efficiency photos, videos and upcoming events. If you're blogging about home performance, this is the place for you!

Don't forget to add your profile photo and be sure to put your location on our Member Map!


Thanks!
Diane, HEP Moderator

 
 
 

Featured Forum Discussions

Too many BTU's. Too much horsepower?

Started by Steve in General Forum. Last reply by Eric Kjelshus on Saturday. 4 Replies

Stack/wind pressure and flow networks.

Started by Daniel James Grundy in Training. Last reply by Daniel James Grundy on Thursday. 5 Replies

BDT with vermiculite in hollow CMU walls?

Started by Brad Cook in General Forum. Last reply by John Nicholas on Thursday. 2 Replies

Strange IR Image

Started by Larry Nissman in General Forum. Last reply by Brad Cook Mar 9. 7 Replies

Videos

  • Add Videos
  • View All

Latest Activity

Charles Maier is now a member of Home Energy Pros
6 hours ago
Derrick Brodanex joined allen p tanner's group
Thumbnail

Energy Auditing Equipment for Sale, Trade or to Purchase

Discuss the pros and cons of the equipment you are interested in prior to purchase. Post equipment…See More
yesterday
Eric Kjelshus replied to Steve's discussion Too many BTU's. Too much horsepower?
"Its more about run time with high RH removing, than to large over sized AC unit, in houses.  …"
Saturday
Sarah OConnell posted a blog post

Crowdsourcing for Innovation

Share Your Ideas!Novel Building Envelope Design for Increased Thermal PerformanceIn 2014, more than…See More
Friday
Colin de Paor is now a member of Home Energy Pros
Friday
Walter Ahlgrim replied to Steve's discussion Too many BTU's. Too much horsepower?
"The 5 ton system you have is not 500 hp racecar engines they are 500 hp truck engines. The duct…"
Friday
Daniel James Grundy replied to Daniel James Grundy's discussion Stack/wind pressure and flow networks.
"So I wanted to start with a basic who can help then go into more detail later. But yes find…"
Thursday
Daniel James Grundy replied to Daniel James Grundy's discussion Stack/wind pressure and flow networks.
"My tutor got back to me and while areas don't quite feel right a little to much assumptions…"
Thursday

Home Energy Pros

Welcome to Home Energy Pros – the unique digital community by and for those who work in the home energy performance arena.

Home Energy Pros was founded by the developers of Home Energy Saver Pro (supported by the U.S. Department of Energy) and brought to you in partnership with Home Energy magazine.  Home Energy Pros is sponsored by the Better Buildings Residential Network. Please honor our Guidelines

© 2017   Created by Lawrence Berkeley National Laboratory.   Powered by

Badges  |  Report an Issue  |  Terms of Service