Dale Sherman's Discussions

ASHRAE 62.2-2013 released
5 Replies

Okay, so has anyone had time to scrutinize the just-released ASHRAE 62.2-2013 standard?  How different is it from Addendum r?I…Continue

Tags: 62.2-2013, ASHRAE

Started this discussion. Last reply by Rick Karg May 8, 2013.

 

Dale Sherman's Page

Latest Activity

Dale Sherman's photo was featured

pressure house cutaway view

A cutaway view of most of the pressure zones measured with respect to (WRT) the adjacent space. A touch of a button changes the pressure readings to a global (outdoors) reference for training architects and scientists.
Mar 31
Dale Sherman replied to Bud Poll's discussion CO poisoning in Yarmouth Maine
"Here is a more detailed article about the incident.  Rescuers measured 1,000 ppm in the bedroom! A picture of the concentric vent is shown and it looks like the intake is partially blocked with snow.   "
Feb 13
Dale Sherman commented on Anna Jursik's blog post Electric Thermal Storage vs. Heat Pump Water Heaters
"NYSWDA did a small study in upstate NY in which the majority of HPWHs installed were Gen 1 GE GeoSpring 50 gal. Our study indicated that in some cases we achieved a Savings-Investment-Ratio (SIR) greater than 1.0 and in some cases we did not,…"
Nov 18, 2013
Dale Sherman replied to Roman's discussion Range Hood Draft
"Home Energy Magazin has a picture of how to use a box to measure flow at a range hood from an August 2012 article. You can use the Energy Conservatory Flow Meter, or make a similar box and cut a hole.  Simply poke a hole for a manometer…"
Oct 16, 2013
Dale Sherman replied to billy g pinnick jr's discussion Implementing ASHRAE 62.2
"A lot of questions requiring some lengthy answers, but I’ll try to keep them concise.  In NY, we are in the process of switching from 62.2-2010 to 62.2-2013.  While it is an improvement in many ways, there are still some…"
Oct 16, 2013
Dale Sherman commented on Lester Shen's blog post Leveraging Human-Building Interaction (HBI)
"It's one thing to design and build new structures using state-of-the-art interfaces for occupants to intuitively manage their environment, but quite another to incorporate HBI equipment into existing structures.  The plethora of engineered…"
Aug 20, 2013
Bradley Wiesneth commented on Dale Sherman's photo
Thumbnail

pressure_house

"I had the pleasure of seeing NYSWDA's pressure house.  It is amazing!!!"
Jun 24, 2013
Dale Sherman commented on Chris Dorsi's photo
May 10, 2013
Dale Sherman's discussion was featured

ASHRAE 62.2-2013 released

Okay, so has anyone had time to scrutinize the just-released ASHRAE 62.2-2013 standard?  How different is it from Addendum r?I see it has finer increments in the Ventilation Air Requirements table 4.1.  That's good.Be sure to get the Errata sheet.Qinf = may be no greater than 2/3 * Qtot.  I read that as meaning even leaky houses may need mechanical ventilation. Anyone have a -2013 spreadsheet calculator yet?Will the $20…See More
May 8, 2013
Rick Karg replied to Dale Sherman's discussion ASHRAE 62.2-2013 released
"Paul Francisco's alternative method is just fine. He has simplified the math for the procedure. Even with Paul's simplification, a spreadsheet or calculation sheet is a good idea. Regarding ductwork, remember that the ASHRAE 62.2 Standard…"
May 8, 2013
Dale Sherman replied to Dale Sherman's discussion ASHRAE 62.2-2013 released
"Very convenient web tool, Rick, makes it easy to run the calculations.  I'm glad to see the improvements in 62.2-2013, such as more weather stations and a refined Table 4.1.   The ELA calculation is still a thorny calculation,…"
May 7, 2013
Rick Karg replied to Dale Sherman's discussion ASHRAE 62.2-2013 released
"Thank you, David. Watch the RED website; more tools and features are being added frequently. "
May 6, 2013
David Meiland replied to Dale Sherman's discussion ASHRAE 62.2-2013 released
"Excellent calculator, Rick, very much appreciated."
May 5, 2013
Rick Karg replied to Dale Sherman's discussion ASHRAE 62.2-2013 released
"OK, one question/answer at a time: Yes, I have scrutinized the 2013 and presented a session at ACI Denver (May 2013) with Paul Francisco that compared 62.2-2010 with 62.2-2013. Qinf may not be greater than 2/3 Qtot for NEW homes only. This is not a…"
May 5, 2013
Dale Sherman posted a discussion

ASHRAE 62.2-2013 released

Okay, so has anyone had time to scrutinize the just-released ASHRAE 62.2-2013 standard?  How different is it from Addendum r?I see it has finer increments in the Ventilation Air Requirements table 4.1.  That's good.Be sure to get the Errata sheet.Qinf = may be no greater than 2/3 * Qtot.  I read that as meaning even leaky houses may need mechanical ventilation. Anyone have a -2013 spreadsheet calculator yet?Will the $20…See More
Apr 25, 2013
Dale Sherman replied to Pat Dundon's discussion Basements and BAS
"Generally, the older the house, the nastier the basement.  If we do a good job of air-sealing a house, where is the remaining infiltration air coming from? If the path from outside to the living space is via the basement, how much is the air…"
Mar 28, 2013

Profile Information

Company
NY State Weatherization Directors' Association
Professional Certification
EPA Supervisor, Renovator, BPI BA
Professional Interests
Education strategies, pressure diagnostics, baseload diagnostics, Passivhaus, sustainable design.
Website URL
http://www.nyswda.org

Dale Sherman's Photos

Loading…
  • Add Photos
  • View All

Comment Wall (1 comment)

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

At 9:07am on November 4, 2010, Carol A. Markell said…
Welcome Dale
 
 
 

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.  Home Energy Pros is sponsored by the Better Buildings Residential Network.

Latest Activity

Colin Genge's video was featured

Passive House Testing Webinar (Feb 13, 2014)

We covered: - Measuring air leakage in a tight house; - New passive house testing equipment; - Powered flow hoods for accurate measurement of HRV ERV flow ra...
2 hours ago
Colin Genge posted events
9 hours ago
John Nicholas replied to Sean Lintow Sr's discussion Duct Testing - is a change in order? in the group Best Practices (Residential)
"Yes,  I was connected to the AH cabinet.  I find it easier in this area, given the common…"
11 hours ago
Colin Genge replied to Kim Tanner's discussion Blower Door Applications Guide in the group Multifamily Buildings
"This is a great guide that anyone testing with multiple fans should get hold  of. "
12 hours ago
Colin Genge added a discussion to the group Multifamily Buildings
Thumbnail

Just posted a lot of Multi-Family oriented blower door videos.

Just posted a lot of Multi-Family oriented blower door videos. Everything to do with Multi-Fan…See More
12 hours ago
Colin Genge joined Norm Bourassa's group
Thumbnail

Multifamily Buildings

For too long there has been relatively little EE focus on multifamily, but some new programs have…See More
12 hours ago
Colin Genge replied to Sean Lintow Sr's discussion Duct Testing - is a change in order? in the group Best Practices (Residential)
"I would assume you tested that high air leakage from the equipment cabinet and not on a flex…"
13 hours ago
Colin Genge replied to Sean Lintow Sr's discussion Blower Doors & Methods Used in the group Best Practices (Residential)
"For those of you who need  a Tectite report, FanTestic's report Generator is powerful…"
13 hours ago