I am looking for ideas for a log home retrofit. 20 years old, cathedral ceiling, full basement and double pane glass. Conditioned space 1500 sq'. Blower-door reveals 5500 cfm50, smoke shows lots of…Continue

Started this discussion. Last reply by Ed Ballard Nov 13, 2011.

 

Bruce Glanville's Page

Latest Activity

Bruce Glanville replied to robert jones's discussion Should your local weatherization company be required to have someone BPI certified on their staff?
"I have been testing homes for my state utility as a baseline residential load data collection program since 2011. Some of these homes were certified Energy Star 2 or 3. Most of them failed duct and/or envelope infiltration standards. QA is a big…"
Mar 5
Bruce Glanville replied to Bruce Glanville's discussion Log Home Retrofit
"This is an older (20?) manufactured log home with matching, machined groves on the mating surfaces."
Nov 13, 2011
Bud Poll replied to Bruce Glanville's discussion Log Home Retrofit
"Hi again, You are correct, fiberglass along the vent channel is a major source of heat loss and an area where you can extrapolate some good numbers.  With cathedral ceilings the area increases and thus the heat loss.  6" of fg,…"
Nov 11, 2011
Bud Poll replied to Bruce Glanville's discussion Log Home Retrofit
"Hi Bruce, The wife and I would like a log home/camp, but as you are learning, they just don't measure up to an energy auditor's dream.  We will shift to stick built and use the simulated log siding.  Now, I'm still a novice…"
Nov 11, 2011

Profile Information

Company
On Earth Energy Group llc
Professional Certification
HERS, BPI, USGBC Green rater
Professional Interests
Sustainable housing, residential energy retrofits
Website URL
http://nrgrater.com

Comment Wall

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

  • No comments yet!
 
 
 

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.  Home Energy Pros is sponsored by the Better Buildings Residential Network.

Latest Activity

Hannah Finch posted a blog post

Want to Lead a Breakout Session at RaterFest! 2015?

We are adding something new to RaterFest! this year... attendee led breakout sessions on Saturday…See More
2 hours ago
Rod Fox replied to Rod Fox's discussion Does calcification affect electric water heater aquastat temperature sensor performance?
"We're in climate zone 5 (near Santa Fe, NM) where it's dry as a bone. Gonna head to that…"
4 hours ago
Bud Poll replied to Rod Fox's discussion Does calcification affect electric water heater aquastat temperature sensor performance?
"The two 4500 watt elements will never operate simultaneously.  It will be one or the…"
4 hours ago
Rod Fox replied to Rod Fox's discussion Does calcification affect electric water heater aquastat temperature sensor performance?
"Correction to this last posting... This model only operates one element at a time, not two in…"
4 hours ago
Rod Fox replied to Rod Fox's discussion Does calcification affect electric water heater aquastat temperature sensor performance?
"Agreed. Incidentally, I just called tech support at Bradford White (and actually spoke to a…"
4 hours ago
Hans Joachim Preiss replied to Rod Fox's discussion Does calcification affect electric water heater aquastat temperature sensor performance?
"Rod, Because the tank is not overheating, the behavior is either normal for this tank or there is a…"
4 hours ago
Rod Fox replied to Rod Fox's discussion Does calcification affect electric water heater aquastat temperature sensor performance?
"Hey thanks Hans. I didn't know about the benefit of the heatpump units having the elements…"
4 hours ago
Rod Fox replied to Rod Fox's discussion Does calcification affect electric water heater aquastat temperature sensor performance?
"I'm not sure if the tank was flushed at the time of element replacement. I would have hoped…"