Controlling Airflow in Existing Dwellings

The new concept of "controlling airflow" is discussed with a Savings-to-Investment Ratio (SIR) calculated. Controlling airflow includes 1) air sealing to red...

Views: 112


You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

Comment by Rick Karg on June 26, 2014 at 9:04am

David, I am the guy who put together and narrated the video.I am sorry you missed the section in the video about increased heating load resulting from ventilation, which was 6.4 therms (slide 9). I did mention the increased cooling load, but did not include it in the SIR calculation because of the location; Portland, Maine, where cooling is a minor issue. If you use this analysis in a heating/cooling climate, both the heating and cooling load increases from ventilation should be included in the SIR equation numerator. The RED Calc Free Advanced Infiltration tool reports both heating and cooling loads.

Regarding maintenance, you are correct, I did not include any maintenance costs. If these were included they would be subtracted from the numerator as a recurring annual cost and would lower the SIR value. I ignored these costs because we don't have a good idea of what they are. Of course, there will be some homeowner work involved, such as cleaning the ventilation fan blades, etc. We hope to get a better idea of maintenance costs for ventilation systems within the next five years or so.

It is best practice to add ventilation to each room using ductwork, as you suggest, but it is not required by the ASHRAE 62.2 standard. I assumed a high quality exhaust fan installed in a centrally located bathroom would provide local and whole-building ventilation (this complies with ASHRAE 62.2). If the ventilation system is more complex, the cost of installation would increase. This would, of course, impact the SIR value. A ventilation system that distributes fresh air evenly throughout a home is preferred. However, it is common that this best-practice solution will not fit into the project budget, especially for the folks working within the low-income weatherization program.

Comment by David Eakin on June 26, 2014 at 8:20am

You did not add the (other) expected yearly running costs for the ventilation unit (additional air conditioning costs for heat/coll/dehumidify, any replacement parts/service, etc.) in the initial SIR computation; you only talk to the fan electrical costs. Also note: if the structure does not already have duct work (a very common occurrence in older buildings) the additional ventilation duct work costs make this proposal very costly, and assuming a single exhaust fan will provide adequate ventilation to each individual occupied room - especially with closed doors - without dedicated duct work is problematic regardless of what the ASHRAE prescriptions preach. It is the reason why paired supplies/returns are the best way to deliver conditioned air to each occupied room vs. central supplies/returns.

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.  Home Energy Pros is sponsored by the Better Buildings Residential Network.

Latest Activity

Walter Ahlgrim replied to Rod Fox's discussion Utility Meter Accuracy
"The problem is this metering type of system cannot be accurate if the load is less than 20% of the…"
1 hour ago
Dennis Heidner replied to Rod Fox's discussion Utility Meter Accuracy
"yes,  I'd think even for a very large house / residence that you'd want to look…"
1 hour ago
Bob Blanchette replied to Rod Fox's discussion Utility Meter Accuracy
"50KW is REALLY pushing it on a standard residential meter, that's 208A @ 240v. $873 minimum…"
3 hours ago
Dennis Heidner replied to Rod Fox's discussion Utility Meter Accuracy
"Yup,  but it also looks like for the tariffs above residential services that they include…"
9 hours ago
Dan McKee posted a blog post

9 Tips To Get Your Furnace Winter Ready

A well heated, cozy home is what makes the day better when the winter comes in full fledged. So, it…See More
11 hours ago
Tauran Ivall replied to Tauran Ivall's discussion Energy Efficient Entry Door options out there?
"Thanks Graham, There is a distributor in Portland for them. Thanks for the link to the blog.  "
13 hours ago
Bob Blanchette replied to Rod Fox's discussion Utility Meter Accuracy
"The use of CT's screams commercial service, most likely over 200A. 200A and lower uses simply…"
13 hours ago
Dennis Heidner replied to Rod Fox's discussion Utility Meter Accuracy
"It's not just the CT's that you need to worry about.   The CT will pick up the…"
18 hours ago

© 2015   Created by Lawrence Berkeley National Laboratory.   Powered by

Badges  |  Report an Issue  |  Terms of Service