Spot the Design Weakness - For Northern Climates

If we had a dime for each weak building assembly detail we saw, we’d be rich. In our 14 years of diagnosing comfort problems for clients; the exposed floor ranks as one of the most stark discomfort features of a home, new or old.

Walking home from the coffee shop Sunday and came across the feature below. Have a look at the photo and see how many design errors you can pick out:

Exposed floor with duct

1- The 2nd floor cavity is exposed above the front door.

2- The metal duct travels in a floor joist cavity past eh stone veneer covering a steel beam.

3- There are pot lights in the eaves.

Even 2LBS spray foam won’t ward off the discomfort in this small but significant exposed floor. How can it, the poor design will handicap it and soon enough all will be covered with lovely aluminum perforated soffit and who will know better.

So here’s the blow by blow, spray foam doesn’t stick well to oiled metal, there’s not enough room between the bottom of the duct and future soffit and though code does allow R12 they won’t get 2″ on the bottom. The duct will lose flow and warmth as it passes so close to the outdoors only to come back in. It runs close and may even touch 2 uninsulated metal beams. Lastly, let’s keep our finger’s crossed that the open joist cavity above the stone wall is continuously sealed otherwise that whole floor cavity above the entire foyer will feel cold to the touch on both sides (main floor and second).

As for the pot lights in the eaves, they are hard to change when they burn out and often create too much heat enough at times to create and ice dam.

Views: 1114


You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

Comment by tedkidd on October 25, 2013 at 11:24am

Nice post Greg! 

Mind if I add to your list?  

4 - furnace will be oversized, so cycle times will be short thereby insuring that in heating season this duct will deliver cold air to a cold room. (You don't deliver hot air through cold duct.)

There is only so much you can do when multiple design flaws occur.  Often correcting for a few means the penalty due to the unsolvable (overhang) becomes insignificant.  I'd move the supply in as far as possible and use closed cell spray foam to this whole area.  

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.  Home Energy Pros is sponsored by the Better Buildings Residential Network.

Latest Activity

Profile IconDenise Cooper, Maren Cooke, Steven Antonini and 1 more joined Home Energy Pros
16 hours ago
Crosbey Archery joined Allison A. Bailes III's group


HVAC design, Manuals J, S, T, & D, Duct leakage, Air flow, ENERGY STAR new home requirements,…See More
Crosbey Archery commented on Ottawa Furnace Filters's blog post Some Useful Information about Furnace Air Filters
"This post is really helpful especially to those homeowners who are still confused on what to…"
Diane Chojnowski posted videos
Diane Chojnowski posted a discussion

Incentives & financing options for home energy upgrades has a useful database of incentives and financing options for home energy efficiency…See More
George Kopf commented on Home Energy Magazine's blog post My Fall Into The Smart Home, Lazy Life
"Matt, Another way of looking at this is that by freeing up my time/brain power, I can give more…"
Chris Laumer-Giddens's blog post was featured

Sparky Doubled the Air Leakage in this Home!

Sparky Doubled the Air Leakage in this HomeThis is the home.This is the hole that Sparky…See More
Chris Laumer-Giddens posted a blog post

Sparky Doubled the Air Leakage in this Home!

Sparky Doubled the Air Leakage in this HomeThis is the home.This is the hole that Sparky…See More

© 2015   Created by Lawrence Berkeley National Laboratory.   Powered by

Badges  |  Report an Issue  |  Terms of Service