Spot the Design Weakness - For Northern Climates

If we had a dime for each weak building assembly detail we saw, we’d be rich. In our 14 years of diagnosing comfort problems for clients; the exposed floor ranks as one of the most stark discomfort features of a home, new or old.

Walking home from the coffee shop Sunday and came across the feature below. Have a look at the photo and see how many design errors you can pick out:

Exposed floor with duct

1- The 2nd floor cavity is exposed above the front door.

2- The metal duct travels in a floor joist cavity past eh stone veneer covering a steel beam.

3- There are pot lights in the eaves.

Even 2LBS spray foam won’t ward off the discomfort in this small but significant exposed floor. How can it, the poor design will handicap it and soon enough all will be covered with lovely aluminum perforated soffit and who will know better.

So here’s the blow by blow, spray foam doesn’t stick well to oiled metal, there’s not enough room between the bottom of the duct and future soffit and though code does allow R12 they won’t get 2″ on the bottom. The duct will lose flow and warmth as it passes so close to the outdoors only to come back in. It runs close and may even touch 2 uninsulated metal beams. Lastly, let’s keep our finger’s crossed that the open joist cavity above the stone wall is continuously sealed otherwise that whole floor cavity above the entire foyer will feel cold to the touch on both sides (main floor and second).

As for the pot lights in the eaves, they are hard to change when they burn out and often create too much heat enough at times to create and ice dam.

Views: 967

Comment

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

Comment by tedkidd on October 25, 2013 at 11:24am

Nice post Greg! 

Mind if I add to your list?  

4 - furnace will be oversized, so cycle times will be short thereby insuring that in heating season this duct will deliver cold air to a cold room. (You don't deliver hot air through cold duct.)

There is only so much you can do when multiple design flaws occur.  Often correcting for a few means the penalty due to the unsolvable (overhang) becomes insignificant.  I'd move the supply in as far as possible and use closed cell spray foam to this whole area.  

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.

Latest Activity

Dennis Heidner commented on Dale Stephens's blog post LED Lighting 24-month update 18,240 hours & counting
"Dale, good write up. For the landscaping bulbs,  if they had been T3 12V wedge bulbs,  I…"
1 hour ago
Brett Little commented on Tom White's video
Thumbnail

The Future of Housing - And How Airtightness Can Help

"It's very true! So many people and contractors have tons of insulated attics but no air seal…"
3 hours ago
Chris Leach replied to Richard Beyer's discussion "The Dangers of Using Spray Foam Insulation"
"The problems will surface soon enough . Why don't we take a second look at this over rated…"
4 hours ago
Don Fitchett commented on Tom White's video
6 hours ago
Profile IconJean-Paul, Bryan and Erica Sullivan joined Home Energy Pros
8 hours ago
tedkidd replied to Bob Blanchette's discussion How does Cycles Per Hour affect real world AFUE?
"Want to spot a simpleton? It's a guy who thinks EE and comfort are disconnected.  Want…"
8 hours ago
tedkidd commented on Tom White's blog post Clean Energy Works Oregon: Total Home Performance
"Nice post Tom! I really like how he puts that. Leveraging interests so they can optimize…"
8 hours ago
Kent Mitchell commented on Tom White's blog post Clean Energy Works Oregon: Total Home Performance
"As a contractor in the region - we frequently wonder how/why you can be a non-profit?  Oregon…"
10 hours ago

© 2014   Created by Lawrence Berkeley National Laboratory.

Badges  |  Report an Issue  |  Terms of Service