When completing your site survey for Manual J Load Calculations, significant time can (or should) be spent identifying window values.  Did you know that most windows these days come with an NFRC rating, a tag located in the window jam that you can reference on NFRC.org? This identification number can tell you important details like window coatings, u-value, light transmittance, air leakage, and solar heat gain coefficients (SHGC).  Not identifying the correct values can sway your load calculation thousands of Btu's per hour in both directions, in heating and cooling.  Of course, the SHGC impacts the cooling load more heavily. 

  There are a few things that can influence the solar heat gain through a window or glass door.  You can manage these gains by installing awnings and/or exterior shades, but the easiest way is to use windows with low SHGC values.  Rated on a scale of zero to one, the lower the value than the less btu/hr gains from the suns rays make it into your home.

  Using a leading load calculation software program, I was able to create a few scenarios to display the importance of spending the extra few moments at the customer's home during the sales process and site survey.  When adding a 4'x6' bay style, facing south, vinyl frame, double-pane, and clear window, the cooling load was increased by a total btu/hr of 1,045.  If spending the time to include the shading default of medium color blinds at 45 degrees, and an outdoor insect screen (50%), then the load of the window can be minimized to only 790 btu/hr.

  If the contractor spent the extra few moments to identify the NFRC rating of the window, they may have been able to establish there is a low-e coating on this particular window.  When including only the coating, not the blinds and insect screen, the cooling load of the window was minimized to just 688 bu/hr.  You can see how missing this feature, multiplied by all of the windows in the home can contribute to improperly over-sizing equipment and IAQ issues like high humidity, etc.  Also, this can change the system design process when selecting equipment and designing ductwork in the ACCA Manuals S and D.  Or, maybe the window faces another direction, and this creates a spike in the "adequate exposure diversity" that could otherwise require zoning.

  On the bright side, no pun intended, you can see how installing blinds and insect screens could deflect the sun's rays just enough to possibly make an uncomfortable room bearable under high loads.  When a homeowner is uncomfortable in particular rooms, it always turns into an HVAC Contractor's nightmare to appease them.  Instead of blaming the airflow, ductwork, or even system sizing, maybe you should look to those wide open skylights and bay windows.  Sure, I like the sun, but sometimes you have to compromise in order to feel "comfortable" when it is 100F and sunny outside.

http://excessair.blogspot.com/2012/06/site-survey-windows-shgc.html

Views: 296

Comment

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

Comment by David Williams on June 21, 2012 at 8:34am

We're in the same ballpark but we might be on different teams. More likely due to location than ideology.  I also rely on thermal load calculations and am particularly vested in solar impacts in a heat dominant climate.  I have  modeled, designed and built  passive solar structures for about three decades.  The impact of solar gains will contribute a great deal to overall energy use (both ways depending on climate and design),  but I have found that there are very few tools that correctly model usable gains.  Several years of research and monitoring has shown that most tools give no heat contribution value to passive solar gains , which have offset nearly half of the required "heat" energy requirements of homes that we have monitored.  This is substantial and has done much to discourage the use of passive solar design.  Our climate, at a 65F base has 8543 HDD and 205 CDD.

Comment by Christopher Morin on June 11, 2012 at 4:13pm

Thanks for reading my blog Linda!  Sorry you feel so negative towards the Load Calculation process.  I firmly believe that  there is no substitute for measuring, but an educated guess on Infiltration and duct leakage is not exactly a WAG.  If the home turned out to be semi-loose instead of average, I doubt it would change the size of the equipment. Not to mention that where I live, and most of the country, requires a Manual J (v8) Load Calculation as part of the Building Code.  A process that was developed by the most successful HVAC contractors in the country, refined over the last few decades, and ANSI accredited - in my mind has real value!  If you are not using load calculation software to size equipment (Heat loss/gain), dare I ask your method(s)?

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy, under the American Recovery and Reinvestment Act) and brought to you in partnership with Home Energy magazine.

Latest Activity

yangxiaohua posted a blog post
3 hours ago

John Abdo just added their location.
(via Member Map)

4 hours ago
Nick Helmholdt replied to Joshua Knittel's discussion Google Thermal View? in the group INFRARED THERMOGRAPHY USERS
"Any bets on how long it will take this company to land in court? A local energy efficiency group in…"
10 hours ago
Matthew Redmond posted a photo
11 hours ago
Matthew Redmond posted a status
"Full house for NYSWDA's ASHRAE 62.2 course today. A lot of discussion on implementing this standard on NY State's diverse housing stock."
11 hours ago
Paul Scheckel posted a blog post

Less oil, more courage: Energy and Art

Hard to admit, but I'm not all fun-facts all the time. Sometimes I even pay attention to things…See More
12 hours ago
Tom Delconte posted a blog post
14 hours ago
Profile IconBarbara Hall and Adam brown joined Home Energy Pros
18 hours ago
tedkidd replied to Jose Macho's discussion Why Are Energy-Saving Home Inprovements Down??
"Pat, I think you and I agree on a LOT of things.   One thing I don't want to see is more…"
yesterday
tedkidd commented on Tom Delconte's blog post Robert Shiller Says Retrofits Are Never Worth It!
"Bob B.   Buying a home is a good investment because it is forced savings more than a good…"
yesterday
Joe Huang posted a discussion

White Box Technologies launches Web-based weather data for building energy simulations

White Box Technologies is pleased to announce under agreement with ASHRAE the launch of WBT Weather…See More
yesterday
Joseph Lamy commented on Jim Gunshinan's blog post The Universe Is Made of Stories
"My life changed when I got 'ductalatored' - became familiar with proper sizing guides for…"
yesterday

© 2013   Created by Lawrence Berkeley National Laboratory.

Badges  |  Report an Issue  |  Terms of Service