Ridge Vent . . . and Nothing But the Ridge

Can anyone convince me that this picture shows anything other than the fact that the ventilation provided here is effective only in the first five inches down from the ridge? And yes, there is continuous soffit venting that is baffled and open to the outside.

Views: 13730

Comment

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

Comment by Bob Mariani on December 29, 2011 at 3:30pm

Still more natural air flow should persist.  I believe the soffit venting is insufficient.  The air movement should be equal between the ridge and the soffit vents.

Comment by Ed Voytovich on December 29, 2011 at 2:55pm

Bob . . . I'll refer to the black snot as "mildew" in hopes of assuaging to the extent possible the anxiety of the homeowners and the desire of their lawyers for a new Mercedes.   

Thanks for pointing out the fact that the cut-out is somewhere around an inch or less on each side instead of the manufacturers' recommended inch and a half.  Still, could another 3/4" on each side make that great a difference?

There are no gable end vents, and the same pattern of mildew extends the entire length of the ridge.

I suspect that this condition is more typical than not of ridge vents.  When the wind blows across the roof  and the ever-popular Bernoulli's Law (http://scienceworld.wolfram.com/physics/BernoulliEffect.html) comes into play, the downwind side of the vent sucks air out of the attic.  I suspect that it is most likely to take the makeup air from the nearest source (which is the other side of the ridge) than from either gable vents or vents in the soffit.  My thinking is that the high-moisture conditions in this particular house created an interesting experiment, but I am grateful for other thoughts and possibilities.

Comment by Bob Mariani on December 29, 2011 at 1:52pm

Ed, is that mold on the discolored section of the sheathing?  The vent opening should have been larger.  Only a small air flow is occurring.  Also be sure no gable vents are still opened that will short circuit the soffit to ridge vent airflow.

Forum Discussions

Investigating 3257KWH monthly usage issue.

Started by Brent Shapiro in General Forum. Last reply by Joe Konopacki 17 hours ago. 7 Replies

Earn 2 BPI CEUs by Blogging for BPI

Started by Quinn Korzeniecki in General Forum on Monday. 0 Replies

What made this chimney fall down?

Started by Eric Kjelshus in General Forum. Last reply by Eric Kjelshus Jun 15. 5 Replies

Studies on Home Energy Audit Energy Savings Potential?

Started by Julie Saporito in General Forum. Last reply by Danielle Sass Byrnett Jun 15. 5 Replies

Latest Activity

Green ID posted blog posts
9 hours ago
Home Energy Magazine's blog post was featured

The Results Are In: These Are The Most Energy-Efficient Utilities in the US

Our first-ever scorecard of US utilities, released today, reveals striking regional differences and…See More
17 hours ago
Joe Konopacki replied to Brent Shapiro's discussion Investigating 3257KWH monthly usage issue.
"Brent, Using an ammeter, I would measure each 'hot' conductor leaving the fuses. (Find an…"
17 hours ago
Chris Allen is now a member of Home Energy Pros
17 hours ago

Photos

Loading…
  • Add Photos
  • View All

© 2017   Created by Lawrence Berkeley National Laboratory.   Powered by

Badges  |  Report an Issue  |  Terms of Service