More HERS Ratings Expected in 2015

The Residential Energy Services Network (RESNET) announced its collaboration with the International Code Council last week in an effort to help home builders transition to the new 2015 International Energy Conservation Code (IECC). In the upcoming version of the residential building code, RESNET's HERS Index will be an optional compliance path — some people are saying that this compliance path represents the most significant change coming to 2015 IECC

What is the International Energy Conservation Code?

The IECC, which is updated every three years, serves as the national model energy code and becomes mandatory when adopted by a state or local jurisdiction. When a builder builds a home, he/she has to meet the current energy code for the jurisdiction in which the home is located.

Building codes often offer two paths to compliance: prescriptive and performance. The prescriptive path requires the builder to follow the code 100% by the book. The performance path allows the builder more flexibility as long as he/she can prove the "projected annual energy usage" of the home is equal to or less than a home built to code. Many builders are already using HERS ratings as a way to meet current codes. RESNET has 17 national home builder partners and close to 300 regional/state partners.

As we get closer to 2015, RESNET and ICC have agreed to several strategies for making the new code come to fruition. Those strategies include:

  • Joint development and distribution of materials that would promote the "Energy Rating Index" compliance path
  • Development and distribution of materials that would describe and facilitate career enhancement for those in the energy rating field to expand their service offerings to meet the demand for third-party code inspectors
  • Customized ICC Membership for Certified RESNET HERS Raters, which may include discounted code books and training in relevant areas
  • Collaboration and co-branding of standards, guidelines, and other products that address the goals of this cooperation

What's also interesting about 2015 IECC is that it explicitly states what the HERS score will need to be in each climate zone of the United States. You'll notice that the scores are all in the 50s. The HERS Index itself ranges from 0 to 100, and like golf, the lower the score, the better. The HERS Index was, in some part, based on the 2004/2006 IECC. At that time, a rated home with a score of 100 would have just met the code. This improved slightly with the 2009 IECC; homes using that code probably have HERS ratings in the 80s. We'll see a really nice improvement with 2015 IECC's requirements in the 50s.

If a builder chooses to follow the Energy Rating Index compliance path, he/she will need a certified RESNET HERS Rater to perform the home rating. It will be interesting to see how many states adopt the 2015 IECC building code. As of January 2014, only six U.S. states had adopted the 2012 code. Most states (27) are still operating under the 2009 IECC. Given the added flexibility for builders who choose the HERS Index path, we foresee an increase in HERS ratings in 2015 and beyond.

Views: 330

Tags: 2012, 2015, building, code, energy, hers, iecc, index, rater, rating, More…resnet

Comment

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

Comment by Brett Little on June 23, 2014 at 8:35am

Don't forget 2012 IECC as an alternative compliance pathway addendum to also do this

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.

Latest Activity

Todd St.Clair joined allen p tanner's group
Thumbnail

Energy Auditing Equipment for Sale, Trade or to Purchase

Discuss the pros and cons of the equipment you are interested in prior to purchase. Post equipment…See More
38 minutes ago
Todd St.Clair replied to Jim Falakos's discussion Treat Software in the group Energy Auditing Equipment for Sale, Trade or to Purchase
"How long ago did you buy this, if it was good for 5 months? And how much would you take for this."
38 minutes ago
Bud Poll replied to Bud Poll's discussion Basing air exchange on house volume??
"Hi Sean, yes I am struggling with this and that is why I opened the discussion, so a definite…"
2 hours ago
Lynda Wright is now a member of Home Energy Pros
2 hours ago
Sean Lintow Sr replied to Bud Poll's discussion Basing air exchange on house volume??
"Sorry Bud but I think you need to clarify your issues with using volumes to calculate ACH As for…"
13 hours ago
Profile IconWes Anderson, Jean-Paul and Bryan joined Home Energy Pros
Friday
Dennis Heidner commented on Dale Stephens's blog post LED Lighting 24-month update 18,240 hours & counting
"Dale, good write up. For the landscaping bulbs,  if they had been T3 12V wedge bulbs,  I…"
Friday
Brett Little commented on Tom White's video
Thumbnail

The Future of Housing - And How Airtightness Can Help

"It's very true! So many people and contractors have tons of insulated attics but no air seal…"
Thursday

© 2014   Created by Lawrence Berkeley National Laboratory.

Badges  |  Report an Issue  |  Terms of Service