I remember installing some early version residential Energy Recovery Ventilators (ERV) and discovering a potential freezing issue.  Also, if I used only a Heat Recovery Ventilator (HRV) than I would be drying the air during the Winter, and adding significant latent load in the summer.  So, which one do I choose?  The homes are tight enough these days to require mechanical ventilation, and I would much rather a balanced ventilation system that I can control.

Honeywell HRV

 
  An HRV works well for tight, moisture prone homes.  This is because the unit can actually recover up to 85% of the exhaust air's heat, preheating the incoming fresh air.  A small diagram from Honeywell shows how the air crosses paths on the core to cause this transfer, with as little as 10% contamination.  Unfortunately, any ventilation in New England will reduce the indoor relative humidity in the Winter due to the cold, dry fresh air.  This means that in the Summer, the very humid air can be tempered, but will increase the indoor RH and cause an increase in load on your air-conditioner.  Since our part of the country sees approximately 2,500 run hours in heating, and only 500 in cooling, I would recommend installing an HRV on heating only equipment or tight homes with many occupants or latent load in the Winter.  This means there was no need to install a humidifier!

Honeywell ERV

 
  For those homes with an air-conditioner, or concerns about moisture control (too dry in the winter), than I would always recommend an ERV.  An ERV not only transfers the heat, but controls a small amount of moisture as well.  This will not remove the need for a dehumidifer, but will certainly decrease the load caused by your ventilation efforts.  Those old freeze-up problems I saw on the early systems were addressed years ago with more integrated controls that actually sense defrost.  If the temperature in these units get below 20F in the Winter, the fresh air damper closes to increase the temperature of the core and avoid freezing!  The most important feature of the ERV is the moisture transfer.  For instance, if the hot, humid Summer air was to enter the home or central a/c unchecked, this would increase the latent load of the unit and create a situation where the homeowner may be uncomfortable and turn off their ventilation.  By removing up to 80% of this load, there is little tax on the central a/c.  ERV's are most cost effective in extreme climates like New England.  I would also install an ERV in a climate like Miami, extreme latent loads year round.  Just remeber, it is not the outdoor climate that determines which unit to install, it is the indoor climate of the home and possibly HVAC equipment that decides which system is best!

Cross-posted from the Excess Air Blog.

Views: 735

Comment

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

Comment by Christopher Morin on April 21, 2012 at 6:58pm

Thanks for pointing this out George.  Residential systems are about 90% effective when transferring this moisture and heat from the outgoing air - meaning about 10% "cross-contamination".  I am sure some commercial grade systems out there may certify 0%...

Comment by George W. Reynolds on April 20, 2012 at 6:53am

Do the manufactures of ERV's certify that only moisture (H2O distilled grade) will transfer into the fresh air side and that water soluble toxins and aerosols remain in the exhaust stream?

Videos

  • Add Videos
  • View All

Twitter

Latest Activity

Tom White's video was featured

Residential Energy+ - Rocky Mountain Institute from James Brown Media on Vimeo.

Residential Energy+ Rocky Mountain Institute

Residential Energy+ is a Rocky Mountain Institute (RMI) initiative enabling industry actors to capture the $150 billion residential energy upgrades market opportunity, and meet the top unmet demand among homeowners: improved home energy performance.
25 minutes ago
Tom White posted a video
15 hours ago
Chris Stratton liked Kim Tanner's discussion Game of Homes
15 hours ago
Amber Vignieri posted a blog post
22 hours ago
ofer ben -nathan added a discussion to the group HVAC
yesterday
ofer ben -nathan joined Allison A. Bailes III's group
Thumbnail

HVAC

HVAC design, Manuals J, S, T, & D, Duct leakage, Air flow, ENERGY STAR new home requirements,…See More
yesterday
Mary Knox replied to Kim Tanner's discussion Game of Homes
"Sounds interesting. I will definitely try it."
yesterday
Judy Roberson joined Norm Bourassa's group
Thumbnail

Multifamily Buildings

For too long there has been relatively little EE focus on multifamily, but some new programs have…See More
yesterday

© 2016   Created by Lawrence Berkeley National Laboratory.   Powered by

Badges  |  Report an Issue  |  Terms of Service