Cleaning and Replacing The Condenser Fan in Refrigerators

Strange noises emanating from the refrigerator really upsets clients. In addition to the noise, the refrigerator feels warm to the touch. We get these calls often for refrigerator repair services. When we get to their home, more often than not the problem stems from the condenser fan, for some reason it has stopped pulling heat from the unit. More often than not, after removing the back of the fridge so we can check out the problem, we find it’s not as bad as we thought. Most of the time we don’t have to replace the condenser fan. It’s not broken, merely suffering from years of neglect and dirty build up. This could have been avoided had they vacuumed the condenser once a year.

Cleaning the condenser fan is easy. We use a soft brush and remove the dust from the entire unit, and thoroughly vacuum the area. While doing this we explain how cleaning the fan a few times a year will extend the life of their refrigerator, and decrease the number of times they need us. Most of our clients didn't even realize they could remove the back panel and clean the dust and pet hair from the condenser fan.

After removing the dust and pet hair that’s built up over the years, the unit fires back up and works smoothly and quietly again. When we leave the client’s house, they’re happy to have their appliance working properly, and have been freshly educated about how to keep things clean and trouble free.

Every once in a while, we stumble upon one that needs to be replaced. The exact way our technicians handle the situation depends on the fan. Most of the time we've found we need to remove the entire system and replace everything.

Removing the condenser fan and replacing it with a new one isn't difficult. When we have to replace the entire condenser fan unit, we like to take the motor out before removing the fan blades. It’s the system that’s worked best for us.

To get the condenser fan and its motor out of the refrigerator, we simply find where the two wires enter the terminal block and use a pair of pliers to remove them. After that unscrewing the bolts holding the motor in place is easy. Once the motor has been unscrewed we slip the washer and fan blade from the motor shaft. If it’s in good shape, we’ll use the same mounting bracket that was on the old condenser fan on the new system. Once we've attached the mounting bracket, slip the motor in place, making sure it’s securely bolted before attaching the fan blades and then connect the wires to the terminal. After double checking to make sure everything’s securely fastened into place, we use our hands to spin the blades, making sure they spin freely and that they’re not going to catch on any wires. We refrigerator back in and test run it. Once the spin test has been successful, we close the back cover and turn the refrigerator on and listen to make sure everything’s working properly.

Views: 220

Tags: refrigerator, repair

Comments are closed for this blog post

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy, under the American Recovery and Reinvestment Act) and brought to you in partnership with Home Energy magazine.

Latest Activity

Profile IconBarbara Hall and Adam brown joined Home Energy Pros
1 hour ago
tedkidd replied to Jose Macho's discussion Why Are Energy-Saving Home Inprovements Down??
"Pat, I think you and I agree on a LOT of things.   One thing I don't want to see is more…"
17 hours ago
tedkidd commented on Tom Delconte's blog post Robert Shiller Says Retrofits Are Never Worth It!
"Bob B.   Buying a home is a good investment because it is forced savings more than a good…"
19 hours ago
Joe Huang posted a discussion

White Box Technologies launches Web-based weather data for building energy simulations

White Box Technologies is pleased to announce under agreement with ASHRAE the launch of WBT Weather…See More
20 hours ago
Joseph Lamy commented on Jim Gunshinan's blog post The Universe Is Made of Stories
"My life changed when I got 'ductalatored' - became familiar with proper sizing guides for…"
21 hours ago
J.C. Martel replied to J.C. Martel's discussion Disasters & sustainable energy
"Thanks Dennis."
21 hours ago
Judi Lyall joined allen p tanner's group
Thumbnail

Energy Auditing Equipment for Sale, Trade or to Purchase

Discuss the pros and cons of the equipment you are interested in prior to purchase. Post equipment…See More
yesterday
Judi Lyall replied to David Starrett's discussion I am looking for a good IR camera in the group Energy Auditing Equipment for Sale, Trade or to Purchase
"Hi there I am selling my equipment and have a great Fluke TIR for sale for 3600.00    If…"
yesterday
William H Nickerson commented on Tom Delconte's blog post Lykans $29, Vampires $0 !
"66 watts a/sec  -3960 w/min   237600 w/hr   5702400  w/day …"
yesterday
tedkidd commented on Jim Gunshinan's blog post The Universe Is Made of Stories
"I think Tom is busting your chops Jim.  The "drivel" part may not have been well…"
yesterday
Tom Maides commented on Jim Gunshinan's blog post The Universe Is Made of Stories
"Some of the best scientists of the previous 1000 years were also leaders in the Church.  Aside…"
yesterday
Laurie DiDonato posted an event

HERS Rater Training in Massachusetts at Maki Building Center

June 3, 2013 to June 8, 2013
6-Day HERS Rater Training- The first step to becoming a HERS RaterLast Week To Register!Your Cost…See More
yesterday

© 2013   Created by Lawrence Berkeley National Laboratory.

Badges  |  Report an Issue  |  Terms of Service