Assessing long-term PV performance in a low-energy home

Zero Energy Home Friends,

My daily PV output from a 6.56 kW PV system has averaged 22.7 kWh/day over the last two years.

kWh= AC kWh from inverter to grid

irrday= cumulative kWh/m2/day plane of array

pvptmp= array temperature (F) taken on back on one of the modules

obs= elapsed days (August 15th 2012 to August 15, 2014)

To illustrate, my PV output AC over the last two years. IRRDAY is daily cumulative irradiance on the plane of the PV array (kWh/m2). There are about 46 m2 of pv modules (32 ESA 205s) While my PV output looks to have gone down a bit this year, it is coming from lower irradiance primarily. We've had a rainy hot summer.

Now we increase the scrutiny: Here we plot the daily plane of array irradiance against the daily PV power production.

The plot symbols are the Julian dates over the two years (0-365) The mysterious days with high output, but lower irradiance (Julian dates 328 and 329 and 236-240) likely come from something like a well-aimed bird poop on the Licor pyranometer.

Ignoring those, there is a cloud of unusual points which start around Julian date 322 and get worse through the end of the year and also continue in early January. This is cause by shading of the extreme south end of the PV array in November - January by my avocado tree. The avos must be good because they are costing me 5-8 kWh a day during that time. As expected, the impact of the shading is worst around Julian date 340-358 (December 6th- December 24th)-- which is right at the solstice. Also, looking at the first plot, this shading has gotten worse in the last year. I think its time for some trimming. Finally, we can examine how PV performance varies with measured data over time to look for degradation. I created a dummy variable (0,1) for the shading that appears to take place from November 15th to roughly January 16th. (Julian dates 1-16 and 320-365).

The statistical model has an R-squared of 92%-- explains 92% of the variation. The shading is a very significant impact, although the daily solar irradiance is the largest factor (no surprise). PV array temperature has a negative influence (hotter array= worse performance). The variable iT is (irradiance * pvtemp) since solar irradiance is strongly correlated with array temperature in order for the influence of array temperature to properly show itself.

The elapsed days do show a negative course -0.0016 kWh lower each day-- but the term is small, equal to perhaps a kWh in two years. However, this could easily be affected by the growing avocado tree. In fact, a regression on the residual on the above regression showed that this is, in fact, the case. Most of the indicated "degradation" is almost certainly coming from a taller avocado tree in the second year as the shortfall in the prediction is coming during the shading period.

Lisa , just added a Ford Cmax Energi Plug-in to our loads so.... Time to trim! But the PV system appears to keep chugging along.

A further note: You can see most of these factors when you plot the PVoutput to grid against Julian Date and using the year as a plot symbol:

Highest output is in mid March on clear cool days. Output goes down over summer with its heat. And then, starting around November 15th (xlin), the output drops from array shading. This reaches a worse level around Julian date 342 (December 7th-- Pearl Harbor Day-- when it plummets as the output of much of the lower string is lost.

You can read much more than you likely want about the house here:

http://www.fsec.ucf.edu/en/publications/pdf/FSEC-RR-383-12.pdf

On-line data here:

http://infomonitors.com/dpr/

Views: 125

Tags: energy, home, low, photovoltaics, shading, solar, zero

Comment

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.

Latest Activity

Everblue posted a status
"Green job alert! Energy Auditor in Baltimore, MD with Advanced Green Home Solutions. Check it out: http://bit.ly/1xhQuXO"
29 minutes ago
Chris Clay replied to Isaiah Borel's discussion Blown Cellulose VS Blown Fiberglass in the Attic
"The Cold Climate Housing Research Center in Fairbanks, AK has alot of information about this…"
44 minutes ago
Richard L. Sanderson replied to Bud Poll's discussion Inconsistant Local Authority
"Bud: I like the idea of a third party review board. My own experience in local government is that…"
8 hours ago
Matthew Lutz commented on Kaplan Clean Tech's blog post The Difference Between Home Inspection and Energy Auditing [Infographic]
"I would have to agree with Steve on this.  I am a Certified Energy Manager and have performed…"
13 hours ago
Matthew Lutz joined Diane Chojnowski's group
Thumbnail

Hall of Shame

In this group, members share an array of images from the field, showing the kinds of issues…See More
13 hours ago
Matthew Lutz replied to Kari Sauder's discussion Easy Water Heater Venting in the group Hall of Shame
"I have been in the HVAC trade since 1986. I have recently completed a Home or Real Estate…"
13 hours ago
Susan E. Buchan posted an event

EEBA Houses That Work at Hilton Asheville Biltmore Park

November 3, 2014 from 8am to 4:30pm
Registration: 8:00 amSession: 8:30 am to 4:30 pmWorkshop Covers:Introduction to EEBA and its…See More
17 hours ago
Susan E. Buchan posted a status
"EEBA has scholarships to our Houses That Work Sessionsfor Vets! Contact info@eeba.org for more info"
18 hours ago

© 2014   Created by Lawrence Berkeley National Laboratory.

Badges  |  Report an Issue  |  Terms of Service