Air Leakage Testing a New Off-Grid High Performance House

We had the great pleasure of air leakage testing a new off-grid, high performance house last week. It was the most air tight building we’d ever tested!

DSC_0524

Situated on a hill overlooking the sweep of the Saugeen River below.

Builder Steven Dennison of Dennison Homes and building envelope consultant Patrick Andres, a Certified Passive House Consultant (CPHC) have officially produced the most airtight home we’ve ever tested in Ontario for an off-grid build going up in Saugeen Shores. If there’s a tighter one we want to test it!

DSC_0522

From left to right; high-performance tester Shervin Akhavi (BlueGreen Group), Certified Passive House Consultant Patrick Andres and builder Steven Dennison of Dennison Homes take moment to celebrate the home’s air tightness record for Ontario.

This lovely house built on a hillock in farm country, overlooking the Saugeen River had a traditional look. Using Nudura Insulated Concrete Forms (ICF) for the basement walls and 8 inch Structurally Insulated Panels (SIPs) for the above grade walls Steve took it up to 11 and added more insulation!

The exterior walls were clad with another 1.5” of extruded polystyrene and the interior also had an interesting product from Nudura – expanded polystyrene with integral wood strapping at 16”oc.

ENVELOPE DETAILS:

  • R 24 underslab insulation
  • R30 below grade walls
  • R 58 above grade walls
  • R 75 cathedral roof
  • R 80 truss roof
  • Doors were from Fibercraft Door Company in Hanover, Ontario.
  • Windows were produced by  Southwall Insulating Glass of Chicago with a pair of Heat Mirror 88 film in the sealed glazing.

 

DSC_0530

The poly air barrier on the top floor being puffed in by the air tightness test.

The Southwall super-insulating glass with suspended film in a fiberglass window frame were beautiful. These units have a high frame R-value and come in multiple colours with optional stainable wood veneer interiors. George Strickland, the manufacturer’s representative, has been promoting the line in Ontario for the last two years. George says “The Southwall glass units can be included in any type of window frame allowing for adaptability in style and design, in commercial or residential applications.”

George also supplied the exterior thermal doors which were made by Fibercraft. These high performing single and dual (French) doors are made with Fibergalss skins and come in smooth or wood grain stainable finishes. They also came with the Southwall glass built-in.

DSC_0518

Window detail showing the Southwall’s super-insulating glass with suspended films in a fiberglass window frame.

The air leakage rates, with a leaky cellar door came in at an amazingly low 0.52 Air Changes per Hour at 50 Pascals (ACH50) with a mere 32 square inches of equivalent leakage area (ELA). Though the wood stove and HRV were not in yet, this basement door was super leaky and the drywall wasn’t clamping the poly on the second floor.

DSC_0514

Driving in we crossed a half dozen wild turkeys (Meleagris gallopavo).

Views: 1026

Comment

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

Comment by Greg Labbe on December 2, 2013 at 9:35am

Dennis,

I didn't do the WUFI or the PH consulting on this project. Patrick Andres may be able to help you with your query:

http://www.linkedin.com/profile/view?id=80946049&authType=NAME_...

Comment by Dennis Heidner on November 22, 2013 at 4:35pm

What does WUFI show for the drying ability?  

The heat pump is there for spring,summer and autumn cooling to (prevent over heating) correct?

Videos

  • Add Videos
  • View All

Twitter

Latest Activity

Profile IconSteve Last, Paul J Anzalone Jr, Jon Traudt and 1 more joined Home Energy Pros
13 hours ago
Jamie Medlin replied to angela stanzione's discussion Used Weatherization and auditing equipment for sale in the group Energy Auditing Equipment for Sale, Trade or to Purchase
"Please let me know if the flowhood  still for sale. jmedlin@archonenergysolutions.com"
yesterday
Jamie Medlin joined allen p tanner's group
Thumbnail

Energy Auditing Equipment for Sale, Trade or to Purchase

Discuss the pros and cons of the equipment you are interested in prior to purchase. Post equipment…See More
yesterday
Laurie DiDonato posted an event
Thumbnail

HERS Rater Training Discount: Register by 1/6/17 and Get $100 Off! at Energize CT Center, North Haven, CT

January 23, 2017 to February 3, 2017
Become a HERS Rater with the NEHERS Alliance!Online Component: January 23rd-February 3rd, 2017 -…See More
yesterday
angela stanzione replied to angela stanzione's discussion Used Weatherization and auditing equipment for sale in the group Energy Auditing Equipment for Sale, Trade or to Purchase
"Yes, I do. Pictures are above. I have a newer fan, I have a frame in a case and I have panels."
yesterday
Tom Phillips replied to Bruce Ceniceros's discussion How effective are whole house air cleaners?
"re: costs:  I suspect the added UV & PCO & ESP has a big price tag but no clear…"
Thursday
David Baerg replied to angela stanzione's discussion Used Weatherization and auditing equipment for sale in the group Energy Auditing Equipment for Sale, Trade or to Purchase
"Hi Angela, Do you have any fans left?  Frames?  Panels? Thanks, Dave"
Thursday
Hannah Wood joined Leslie McDowell, BPI's group
Thumbnail

Building Performance Institute (BPI)

BPI is the nation's premier standards development, quality assurance and credentialing organization…See More
Thursday

© 2016   Created by Lawrence Berkeley National Laboratory.   Powered by