Air Leakage Testing a New Off-Grid High Performance House

We had the great pleasure of air leakage testing a new off-grid, high performance house last week. It was the most air tight building we’d ever tested!

DSC_0524

Situated on a hill overlooking the sweep of the Saugeen River below.

Builder Steven Dennison of Dennison Homes and building envelope consultant Patrick Andres, a Certified Passive House Consultant (CPHC) have officially produced the most airtight home we’ve ever tested in Ontario for an off-grid build going up in Saugeen Shores. If there’s a tighter one we want to test it!

DSC_0522

From left to right; high-performance tester Shervin Akhavi (BlueGreen Group), Certified Passive House Consultant Patrick Andres and builder Steven Dennison of Dennison Homes take moment to celebrate the home’s air tightness record for Ontario.

This lovely house built on a hillock in farm country, overlooking the Saugeen River had a traditional look. Using Nudura Insulated Concrete Forms (ICF) for the basement walls and 8 inch Structurally Insulated Panels (SIPs) for the above grade walls Steve took it up to 11 and added more insulation!

The exterior walls were clad with another 1.5” of extruded polystyrene and the interior also had an interesting product from Nudura – expanded polystyrene with integral wood strapping at 16”oc.

ENVELOPE DETAILS:

  • R 24 underslab insulation
  • R30 below grade walls
  • R 58 above grade walls
  • R 75 cathedral roof
  • R 80 truss roof
  • Doors were from Fibercraft Door Company in Hanover, Ontario.
  • Windows were produced by  Southwall Insulating Glass of Chicago with a pair of Heat Mirror 88 film in the sealed glazing.

 

DSC_0530

The poly air barrier on the top floor being puffed in by the air tightness test.

The Southwall super-insulating glass with suspended film in a fiberglass window frame were beautiful. These units have a high frame R-value and come in multiple colours with optional stainable wood veneer interiors. George Strickland, the manufacturer’s representative, has been promoting the line in Ontario for the last two years. George says “The Southwall glass units can be included in any type of window frame allowing for adaptability in style and design, in commercial or residential applications.”

George also supplied the exterior thermal doors which were made by Fibercraft. These high performing single and dual (French) doors are made with Fibergalss skins and come in smooth or wood grain stainable finishes. They also came with the Southwall glass built-in.

DSC_0518

Window detail showing the Southwall’s super-insulating glass with suspended films in a fiberglass window frame.

The air leakage rates, with a leaky cellar door came in at an amazingly low 0.52 Air Changes per Hour at 50 Pascals (ACH50) with a mere 32 square inches of equivalent leakage area (ELA). Though the wood stove and HRV were not in yet, this basement door was super leaky and the drywall wasn’t clamping the poly on the second floor.

DSC_0514

Driving in we crossed a half dozen wild turkeys (Meleagris gallopavo).

Views: 1001

Comment

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

Comment by Greg Labbe on December 2, 2013 at 9:35am

Dennis,

I didn't do the WUFI or the PH consulting on this project. Patrick Andres may be able to help you with your query:

http://www.linkedin.com/profile/view?id=80946049&authType=NAME_...

Comment by Dennis Heidner on November 22, 2013 at 4:35pm

What does WUFI show for the drying ability?  

The heat pump is there for spring,summer and autumn cooling to (prevent over heating) correct?

Videos

  • Add Videos
  • View All

Twitter

Latest Activity

George Matthews commented on George Matthews's event Proof is Possible Tour by the Home Performance Workshop
"Here is the flyer for the Advanced Techniques and Tools in Home Performance Friday October 7th at…"
53 minutes ago
George Matthews posted an event

Proof is Possible Tour by the Home Performance Workshop at Truitt and White Lumber Conference Room

October 7, 2016 from 9am to 1pm
Building Energy Performance Testing is sponsoring the Proof is Possible Tour to come to the San…See More
1 hour ago
George Matthews replied to George Matthews's discussion Shortridge 8400 Flowhood for A/C airflow testing in the group Energy Auditing Equipment for Sale, Trade or to Purchase
"Here are the pics of the flowhood and airdata manometer"
Saturday
Sarah Holloway posted a photo
Friday
Joe Urycki added a discussion to the group Energy Auditing Equipment for Sale, Trade or to Purchase
Thumbnail

TEC blower door and UEI combustion analyzer for sale

For sale is one used TEC Minneapolis blower door system: Includes model 3 fan with rings A and B,…See More
Friday
John Nicholas replied to Kevin Emerson's discussion Studies re: radon mitigation and energy efficiency
"The Nay side is well represented with the links already posted. I presented a neutral side, with…"
Friday
Ray Lehman replied to Kevin Emerson's discussion Studies re: radon mitigation and energy efficiency
"Hey John, Thanks for the information.  Very good empirical data. While I agree that running…"
Friday
John Nicholas replied to Kevin Emerson's discussion Studies re: radon mitigation and energy efficiency
"I have no links, just some anecdotal evidence. I had several Blower Door Tests done on my own home.…"
Friday

© 2016   Created by Lawrence Berkeley National Laboratory.   Powered by

Badges  |  Report an Issue  |  Terms of Service