Reposted from i.e., the Center for Energy and Environment's Innovation Exchange blog -- http://mncee.org/Innovation-Exchange/ie/

 

CEE’s Ben Schoenbauer has been travelling around the country recently to share his work to improve the efficiency of domestic hot water systems. His current research project is evaluating the energy savings potential of integrated space and water heating systems, also known as dual integrated appliances (DIA) or combination systems (combi systems). He has been presenting this work to both researchers and practitioners. In support of his outreach, the Innovation Exchange created five animations to show how the parts of the various systems interface and to allow comparisons between them.

The first animation is a conventional hot water and space heating system where a tank storage water heater supplies domestic hot water and a forced air furnace provides space heating to the house.

The second animation shows a combi system where the tank storage hot water heater is used in combination with a hydronic air handler (hot water rather than hot combustion gases from burners circulates in the heat exchanger). The water heater supplies the hot water to the air handler to supply space heating to the house.

 

The third animation is a combi system where an instantaneous, or tankless, water heater has replaced the storage hot water heater. This combi system does not create the standby losses that would occur with a storage tank full of hot water.


The fourth animation shows a combi-system that uses a hydronic boiler rather than a domestic heater as the hot water source. 

 

This final animation, based on results from CEE's field research, lays out the factors that influence the installed efficiency of a combi system.



We hope that these animations will improve your understanding of these systems, whether you’re an appliance expert or a homeowner investigating possible energy improvements. Feel free to link to or embed these videos from this blog post, our resource page, or our YouTube site.

The motion graphics animations were designed and produced by Huma Saqib.

 

Related Innovation Exchange project:

Retrofitting Integrated Space & Water Heating Systems

Related posts:

Residential Water Heater Calculator

ACEEE Hot Water Forum

DIA Lab Field Trip

Views: 1037

Comment

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

Comment by Bob Blanchette on December 10, 2012 at 5:59pm

The combi systems work very well when the heating load is small. Perfect for those situations when you have heating loads under 30k. A conventional water heater can be used with a fan coil. Once you start buying special high BTU water heaters the combi system stops making economic sense.

Comment by Ben Schoenbauer on December 10, 2012 at 12:27pm

There have been issues with the reliability of these systems in the past.  Manufacturers have been working to improve these models and reliability has improved.  There are many manufacturers (Rinnai, AO Smith, American, HTP, Navien, and others) that develop products for this specific purpose and some of them do sell full systems.  

We got interested and involved in this project to support a weatherization project looking to install forced air combi systems as a solution to their need for high efficiency heating with combustion safety and low up front costs. It did take a large effort to optimize and install these systems. We are currently developing best practices and optimization guidelines. Going forward we are looking at several ways to improve the system by reducing the need for optimization and making these systems more accessible to everyone.

   

Comment by Lester Shen on December 10, 2012 at 11:48am

Thanks, Jon. That is indeed a typo. It should be CFM. We'll get that amended. 

Comment by Jonathan Beers on December 10, 2012 at 11:37am

In the final animation, what's "CPM" stand for? Possible typo for CFM? Back when the Lennox Complete Heat and the early Polaris systems were on the market, a few contractors I talked to reported bad experiences. I heard that the more recent attempts at these systems using Munchkin boilers also had some problems.

Building Science Corp put out this document several years ago:

http://www.buildingscience.com/documents/reports/rr-0213-combo-spac...

Comment by Robert C. O'Brien on December 10, 2012 at 11:14am

In the northeast,where the majority of residential boilers are,these are referred to as hydro air systems,a combi is heat and DHW in one unit with heat delivered not using air as a transfer medium ie conventional radiation

Comment by Greg La Vardera on December 10, 2012 at 11:00am

Wait - the description in the above post says "dual integrated appliances". But everybody is talking about cobbing together systems that were not manufactured for that purpose. 

Nobody has an example of a US manufacturer offering an integrated appliance?

No offense intended, but is it my imagination that Energy Consulants are really not interested in dual integrated appliances because many earn a living advising people how to cobble together this kind of system?

Comment by Pat Dundon on December 10, 2012 at 10:47am

My best experience is with a boiler and indirect water heater in a baseboard hot water house.  I found a good way to improve it is a solar hot water system between the well and the indirect tank with circualtion between the two on a relay.  In summer it doesn't overheat, it just makes 120 gallons of 140 degree water.  in my cloudy cold winter environment it means the indirect unit is usually heating water from 75 degrees or hotter to 120, instead of well temperature. 

What I don't know about is wall hung gas fired boilers with built in indirect water heaters. Apparently Rennai (sp?) is building a unit with a 6.5 gallon onboard water heater and instant on hot water combined with a space heating boiler.  I don't see that illustrated here.  does anyone know if they are really effieient, and if so, does the family size effect efficiency because the water runs more? 

Comment by Ben Schoenbauer on December 10, 2012 at 9:50am
Great to see all the interest in this topic.  As Lester mentioned we are currently conducting a field research project (funded by Building America) to characterize the potential of these systems.  Forced air combination systems have been around for a while, but have recently started to be considered again.  There are many manufacturers that offer system components.  Most major water heater manufacturers offer a water heater designed to be the heating plant in a forced air combi system.  Several (including Rheem and Rinnai) have full systems with both the air handler and the heating plant.  
Preliminary results have confirmed the high efficiency potential of these systems. By carefully sizing system components we have been able to reduce water temps and install systems with 90% space heating efficiency.  Performance varies depending on installation, usage and the type of water heater, but our optimized systems have energy use comparable to a condensing furnace and a condensing water heater and because you only need to install a single condensing heating plant installation costs can be reduced.
Comment by tedkidd on December 10, 2012 at 7:23am
Fantastic early Dan Holohan boiler article http://bit.ly/danholohan1992allshookup

Building Science Theory :: a great overview from Bean http://bit.ly/HHhpOverview

BSC Experts Session - Straub and BTU http://bit.ly/BSCexpertsSTRAUB
Comment by tedkidd on December 10, 2012 at 7:18am
These systems definitely have their place, so long as designers understand the unavoidable efficiency sacrifice due to inability to run low water temperatures.

Conflict occurs at the water to air coil. To have effective transfer here, the water must be hot. Dan Holohan, Robert Bean, and as of last week John Straube of BSC have all published the power of running water in the 80f range, a temperature not possible when you add another heat exchange distribution step.

Ideally distribution is directly connected to combustion. This allows lowest possible temperatures, which in turn pull/wring/squeeze (imaging squeezing a sponge) the most BTU out of both the sensible and the LATENT heat of combustion.

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy, under the American Recovery and Reinvestment Act) and brought to you in partnership with Home Energy magazine.

Latest Activity

Ania Divina, SEXY LEDS posted photos
1 hour ago
tedkidd replied to Jose Macho's discussion Why Are Energy-Saving Home Inprovements Down??
"Pat, I think you and I agree on a LOT of things.   One thing I don't want to see is more…"
9 hours ago
tedkidd commented on Tom Delconte's blog post Robert Shiller Says Retrofits Are Never Worth It!
"Bob B.   Buying a home is a good investment because it is forced savings more than a good…"
11 hours ago
Joe Huang posted a discussion

White Box Technologies launches Web-based weather data for building energy simulations

White Box Technologies is pleased to announce under agreement with ASHRAE the launch of WBT Weather…See More
11 hours ago
Tom Delconte commented on Tom Delconte's blog post Lykans $29, Vampires $0 !
"Bill: these are available for free at www.freeenergy.com . Just ask for Jen Guarater! I…"
12 hours ago
Joseph Lamy commented on Jim Gunshinan's blog post The Universe Is Made of Stories
"My life changed when I got 'ductalatored' - became familiar with proper sizing guides for…"
12 hours ago
J.C. Martel replied to J.C. Martel's discussion Disasters & sustainable energy
"Thanks Dennis."
13 hours ago
Judi Lyall joined allen p tanner's group
Thumbnail

Energy Auditing Equipment for Sale, Trade or to Purchase

Discuss the pros and cons of the equipment you are interested in prior to purchase. Post equipment…See More
yesterday
Judi Lyall replied to David Starrett's discussion I am looking for a good IR camera in the group Energy Auditing Equipment for Sale, Trade or to Purchase
"Hi there I am selling my equipment and have a great Fluke TIR for sale for 3600.00    If…"
yesterday
William H Nickerson commented on Tom Delconte's blog post Lykans $29, Vampires $0 !
"66 watts a/sec  -3960 w/min   237600 w/hr   5702400  w/day …"
yesterday
tedkidd commented on Jim Gunshinan's blog post The Universe Is Made of Stories
"I think Tom is busting your chops Jim.  The "drivel" part may not have been well…"
yesterday
Tom Maides commented on Jim Gunshinan's blog post The Universe Is Made of Stories
"Some of the best scientists of the previous 1000 years were also leaders in the Church.  Aside…"
yesterday

© 2013   Created by Lawrence Berkeley National Laboratory.

Badges  |  Report an Issue  |  Terms of Service