In order to feel comfortable in the cooling season conditioned air has to be at the right air temperature AND relative humidity. Conventional AC dehumidifies when it is running but it is thermostatically controlled by air temperature only. Which means that when air temperature is reached the AC turns off and stops dehumidifying. Not a big problem if you live in an arid climate such as Pheonix but if you live in New England where the summers are very humid and not THAT hot then you most likely will never get that perfect comfort combination of cool and dry air.

To exacerbate the problem further a recent North East utility study determined that 100% of AC systems are over designed and that more than 50% are over designed by more than 100%. Which is why summer AC in Connecticut (my home state) is typically cold and dank, (I hate it). Why does this happen? For example; let's take a typical July day, 86 degrees and 95% relative humidity, put the AC on and the system blasts on at 100% capacity and quickly lowers the air temperature and doesn't cycle long enough to dehumidify. Now the air temperature is OK but the occupant is still not comfortable because the air is too humid, so what do they do? Right, they lower the thermostat some more to make the air even colder but it is still too humid. It is actually impossible for the conventional AC system to achieve comfortable conditions.

Bottom line on conventional AC is that is works poorly most of the time. Primarily because it cannot load match and therefor can't cycle properly to control air temperature AND humidity at the same time. My recommendation is to switch to an inverter driven air source heat pump that can modulate to always match the load and actively dehumidify (many actually have a dry mode). This type of operation not only optimizes comfort but greatly contributes to overall system efficiency that is not reflected in the outdated SEER rating system that only measures systems at full capacity working only to lower air temperature. An added bonus is that inverter heat pumps also work amazingly well in heating mode too. Let's stop trying to even make conventional AC work and move on to the next generation of HVAC equipment that does the job right.

Views: 1292

Tags: AC, air, comfort, dehumidification, heat, indoor, pump

Comment

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

Comment by Steven Lewis on May 25, 2012 at 11:25am

MIni splits work fine as spot cooling/heating and inverter tech is great but has a long way to go to meet loads in Kansas. 

Even the manufacturers say their product in not designed to handle whole house loads or conditions.  (Meeting last month with the sales tech rep)    how do you move air from your two rooms to the other 4 to 6 rooms and have any comfort or temp control?  I have installed minisplits and they work in their application but they will not replace whole house central systems  especially at our high elect rates vs low gas prices.  

Just because something is a solution to a problem does not mean it THE solution to all problems. 

Comment by Joseph Novella on May 24, 2012 at 1:14pm

Actually you could install a 3-ton Fujitsu or Daikin mini split inverter heat pump system with two indoor wall mounted air handlers for about $6,500 in a day or so. Also I would not emulate "what the AC pros do" in their homes, thats how we got into our current poor state of affairs regarding horrible system design and deplorable efficiency. 

Photos

Loading…
  • Add Photos
  • View All

Latest Activity

Profile IconTirso De Ubago, Hamed Ghanbari, Bob Eldredge and 1 more joined Home Energy Pros
2 hours ago
Hamed Ghanbari replied to Brian's discussion Everything you need to become a energy auditor for sale in the group Energy Auditing Equipment for Sale, Trade or to Purchase
"Hello, I am interested to buy a Minneapolis Blower Door DG700. How much is your unit? Thanks. "
6 hours ago
Hamed Ghanbari joined allen p tanner's group
Thumbnail

Energy Auditing Equipment for Sale, Trade or to Purchase

Discuss the pros and cons of the equipment you are interested in prior to purchase. Post equipment…See More
6 hours ago
Colin Genge updated an event
Thumbnail

Measuring HVAC Performance webinar at Online

February 23, 2016 from 11am to 12pm
If you install, service or test HVAC systems you will want be there for this special webinar.…See More
9 hours ago
Colin Genge updated an event
Thumbnail

Testing for IECC Code Compliance for duct and house leakage webinar at Online

February 16, 2016 from 11am to 12pm
The International Energy Conservation Code (IECC) is in use or adopted in 47 states, the District…See More
9 hours ago
Jan Green posted a status
"I'm honored to be selected to speak at the 2016 RESNET Conference right here in sunny Scottsdale 2/29-3/2/16 with SRP & others!"
11 hours ago
Joe Konopacki posted an event

Duct & Envelope Tightness (DET) Verifier at Temperature Equipment Corporation

February 26, 2016 from 8:30am to 4:30pm
The Duct & Envelope Tightness Certification (DET) was designed by the Midwest Home Performance…See More
12 hours ago
Diane Jackson liked Don Hynek's discussion Superinsulation retrofit is Complete!
13 hours ago

© 2016   Created by Lawrence Berkeley National Laboratory.   Powered by

Badges  |  Report an Issue  |  Terms of Service