Part 2 of: The "1-2 Punch" to HVAC "Not Understoods"

Proper sizing of HVAC equipment is smaller, and smaller means more comfort.

Probably the usual thought in the HVAC industry by technicians is that the units need to be made bigger for comfort. Perhaps this comes from the idea of coming home from work, and needing a set back thermostat to do its magic, and get the home comfortable fast, before dinner.

What happens when we add too many Btuh to a space too fast? The air gets heated or cooled fast, and then the thermostat detects the rapid change in the air temperature and shuts off the system. After all it made the grade and the air is a good temperature. So all is well. Correct?

What is missed is this: The "average radiant temperature" of the house and furniture has not been changed correspondingly with the rapid change in air temperature. The radiant temperature of the house and furniture has a lot more to do with the perception of comfort than does the air temperature. 

If you remember "radiant heat - or cool" can travel instantly through space and air with little to no resistance. So even if the air is warm, the furniture will beam you with uncomfortable temperatures.

So with the big HVAC system, the air will rapidly warm to the thermostat set point, yes it is true. The house and furniture will then start to change temperature with the new air temperature changes, and then the HVAC system will start to cycle on and off - contributing to swings in temperature. Also the turning on and off of the system will be noticed, and distracting.

  • Like a big truck in traffic - the constant stop and go will use a lot of energy. It will be distracting.

Smaller HVAC is always better. Less Btuh per hour, and just enough, and maybe a little more, to overcome the losses in the shell, will provide maximum comfort. The house radiant temperature would be maintained at the set point of the thermostat. Because the system runs more constantly, the house radiant temperature is held at a steady state. Hot and cold rooms tend to vanish. Smaller systems are quiet and almost not perceptible when they are running. The consistency in internal thermal mass will help save energy, as will the cycling losses of the equipment. 

  • Like a small car on the highway - the constant speeds will use a lot less energy. It still gets you where you need to go. And if you don't notice your HVAC system, it is even more comfortable. Obviously it will get better fuel mileage, as well.

------

Next up: How the 1, 2 punch work together to waste 50-80% of energy spent on HVAC costs. For more information please sign up at www.UpSmart.Tv and connect with the Super Efficient HVAC Series there.

Views: 179

Comment

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

Comment by Christopher Cadwell on December 31, 2011 at 6:04am
If an AC contractor told me that it would not blow enough air, then my response would be to ask for the calculations to show me that there is more cfm needed. Of course they usually cant. So then ask them how they can make an assertion about something without calculations - then just direct them to my blog. Eventually I will have free courses for them to learn about it. Usually you can get about half of them interested, and the other half will just continue to defend themselves against things they do not understand.
Comment by Bob Mariani on December 28, 2011 at 8:55am
I work with inspectors in an attempt to educate. Works sometimes. Changing fan helps. Mostly I try to sell them on heat pumps
Comment by Bruce Navin on December 28, 2011 at 7:57am

So, Bob- How do you handle those objections?

Comment by Bob Mariani on December 28, 2011 at 4:59am

I have tried getting HVAC contractors to spec smaller units after deep energy retro fits.   But they claim the code still requires a certain heat load to be used.  Another response is the house can use a smaller Ton unit but the smaller unit will not blow enough air for the volume of the home.  Another issues is the sizes are no longer available in 1/2 ton.. so you still need to get a 4 ton unit when a 2 1/2 ton should work.

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy, under the American Recovery and Reinvestment Act) and brought to you in partnership with Home Energy magazine.

Latest Activity

Tom Mallard just added their location.
(via Member Map)

6 hours ago
Profile IconDon Hughes, Julian Sark, James Hatheway and 4 more joined Home Energy Pros
8 hours ago
Meagan Foster posted events
9 hours ago
Meagan Foster updated an event

EnergyLogic's RaterFest! at Black Hawk, CO

September 13, 2013 at 10am to September 15, 2013 at 12pm
Join us for one of the best home energy conferences available!  This retreat will provide…See More
9 hours ago
Meagan Foster updated an event

Homes 401: Green Rater Training at Berthoud, CO

June 25, 2013 to June 26, 2013
This highly interactive workshop builds upon the material presented in the online course, further…See More
9 hours ago
Meagan Foster updated an event

HERS Rater Training - Online at Online

July 1, 2013 to July 26, 2013
NEW - our great RESNET HERS Rater online training is now completely self-paced, so you can start at…See More
9 hours ago
Meagan Foster updated an event

BPI Building Analyst Training - Online at Online

June 3, 2013 to June 28, 2013
Join the EnergyLogic Academy for our BPI BA online training - we just went to a completely open…See More
9 hours ago
Anna Svensson posted a discussion

Looking for residential building and remodeling experts

Making sure you residential building and remodeling professionals out there are aware of the call…See More
10 hours ago
Bryce Cramer replied to Mike Kandel's discussion June's Stump the Chump: What's Wrong with this Picture? in the group Building Performance Institute (BPI)
"Key is this was done in warm weather. The back wall of the room was also uninsulated, but the lower…"
13 hours ago
Bryce Cramer joined Leslie McDowell, BPI's group
Thumbnail

Building Performance Institute (BPI)

BPI is the nation's premier standards development, quality assurance and credentialing organization…See More
13 hours ago
James Hatheway added a discussion to the group Job Board
Thumbnail

Quality Assurance Verification Specialist - Little Rock, Arkansas

CLEAResult (clearesult.com) is looking for a QA Verification professional who wants to leverage…See More
15 hours ago

© 2013   Created by Lawrence Berkeley National Laboratory.

Badges  |  Report an Issue  |  Terms of Service