We're Not Paying Enough Attention to Kitchen Ventilation

Exposure to kitchen pollutants is a significant and overlooked health hazard in homes. The home performance industry pays great attention to protecting against exposures to combustion pollutants from water heaters and furnaces, but very little attention to an unvented combustion device that is used nearly every day: the kitchen range. A recent LBNL study looked at the chronic health impacts of exposure to pollutants from cooking burners and determined that the risks are not trivial, especially considering our findings on the prevalence of kitchen ventilation and its use (12).  And the popular media are beginning to take notice (herehere, and here).  

Kitchen ventilation is needed in homes with either electric resistance or gas cooking appliances as both types of burners produce pollutants and because cooking itself creates pollutants, odors, and excess moisture.

The need for kitchen ventilation isn’t on most people’s radar as a health issue. It should be. As we work to create healthy, low-energy homes, we must recognize that “build tight; ventilate right” includes effective kitchen (and bath) ventilation in addition to baseline, “whole-home” mechanical ventilation. Pollutants generated in a leaky home get diluted with infiltrating outdoor air. Pollutants in tight homes stay put. A tight home with ineffective kitchen ventilation and even a moderate amount of cooking is a recipe for bad IAQ and potential health impacts.

Right now, there are four main problems with US residential kitchen ventilation:

  • Many existing homes lack any kitchen ventilation.
  • Homes are being built without kitchen ventilation because it is not required in building codes.
  • Even in homes that have kitchen ventilation, few people routinely use it.
  • Even when they are used, many kitchen ventilation systems are only moderately effective.

These problems are at different scales, and have different causes and potential solutions. But they all need to be addressed together if we want to improve the efficacy of our kitchen ventilation, and to create comfortable low-energy homes that are also healthy.

Building codes and standards, design, education, and marketing, among other approaches, all must play a role in addressing these challenges. But the first step is to recognize them as problems and begin to generate the will to work together to solve them.  

To view the full report, “Addressing Kitchen Contaminants for Healthy, Low-Energy Homes”, click here. Also, look for a more detailed look at the study results in a future Home Energy Magazine issue.

Views: 365

Comment

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

Comment by Chris Stratton on April 7, 2014 at 12:43pm

Graham, great points. I'm a fan of induction. If a full induction range is infeasible, a portable single burner induction cooktop can be an affordable and versatile replacement or complement for a gas or electric resistance range.  

Comment by Graham Irwin on April 3, 2014 at 9:45am

Good idea to stop burning gas inside, induction cooktops eliminate combustion and deliver far more of the heat to the cookware, an additional benefit during cooling season.

Comment by Chris Stratton on April 2, 2014 at 10:58am

Bob, I agree. Vented to the outside is a great place to start. Next on the priority list for me would be the noise level.

Comment by Bob Blanchette on March 30, 2014 at 6:54am

The first thing that could be done is get rid of those recirculating range hoods that 90% of new homes use. Require all range hoods to be vented to the OUTSIDE.

Forum Discussions

Latest Activity

Ed Minch replied to Martin Newmark's discussion Best Practice for Retrofit Insulation on Modern Knee Walls in Attics
"There are 3 problems you are trying to solve.  First, that the face of the insulation is not…"
10 minutes ago
Dan Phillips replied to Martin Newmark's discussion Best Practice for Retrofit Insulation on Modern Knee Walls in Attics
"It is important to also remember the key junctures where the top of the kneewall meets the roof,…"
12 minutes ago
Eric Kjelshus replied to Rob Buchanan's discussion Building envelope and mechanical interactive effects
"Yes I see this with return in attic or boiler way out of tune or AC compressor valves out or gas…"
12 minutes ago
Sean Lintow Sr replied to Martin Newmark's discussion Best Practice for Retrofit Insulation on Modern Knee Walls in Attics
"It gets down to the size of the crawl - I can't recall where I saw it but one contractor cuts…"
2 hours ago

Photos

Loading…
  • Add Photos
  • View All

© 2017   Created by Lawrence Berkeley National Laboratory.   Powered by

Badges  |  Report an Issue  |  Terms of Service