Warnings About Portable Air Conditioners

Warnings About Portable Air Conditioners

Warning About Portable Air Conditioners

Here are some warnings about portable air conditioners to help you to be aware of their low energy efficiency rating when purchasing a new air conditioner. If you already have a portable air conditioner or if a portable air conditioners your only option to get some cooling, these fair warnings may help you understand your air conditioner and make better use of it. We will look in details why portable air conditioners are taking more room, wasting more power, producing more noise, and costing more money.If you are in a hurry, just looked the colored text, bookmark this page, and come back later when you have time.

Warning about "Portable"

An major claim of portable air conditioners is that they do not need installation and they are portable. On the internet or in the showrooms, we see portable air conditioners neatly displayed without a hose most of the time. In reality all air conditioners need to pass heat to the outside. Central air conditioners and window air conditioners use Freon to carry the heat to the outdoor coils. Fans are used to drive air to cool the outdoor coils.

Portable-Air-Conditioner-Installations

A portable A/C brings the outdoor coil inside the room but still need to cool the coil. The coil passes the heat to air then the hot air has to be sent out the house. These pictures show portable A/C in actual use. They are less prettier than the units themselves – everyone has at least one bulky hose connected to the outside. Tip: The longer the total hosing the more power will be wasted to drive air through the hose.

Portable air conditioners need venting kits installed almost the same way as window air conditioners. It is true that the venting kit is much smaller than a window unit. However, you may run into the same installation problems as installing window air conditioners. Do you like the installations in the pictures? Think what the installation will look like in your house when deciding the purchase.

Once installed like the above, “Portable” is questionable. To move the portable A/C to different rooms, we need the venting kit installed in every room or re-install the venting kit for every move. Small wheels may not move well on carpets. Will the move be practical for you? Will the move be easier than with a window air conditioner? Tip: A window air conditioner is more efficient and weigh less as you see below.

Warning on Lower Energy Efficiency

The cooling capacity of an A/C is defined by its BTU/h rating. The BTU/h number indicates the amount of heat the air conditioner can remove from a room each hour. A hot climate will need more heat to be removed from a room to feel cool. A cooler room will also need more heat to be removed for the deeper cooling.

Here are recommendations from HomeDepot.
air_conditioner_btu_calculator
We can see from these two tables, comparable portable units will cool less space than window units. Take the recommended 12,000 BTU units for example, a portable air conditioner is recommended for a 400 square feet roomwhere a window unit is recommended for a 550 square feet room. In other word, for the same sized room, we will need a higher BTU portable unit.

The power needed to run an A/C is tied to its EER (Energy Efficiency Rating). Also at HomeDepot, the highest EER of portable air conditioners is 9.5 like the Haier CPN14XH9. For this 14,000 BTU unit to work, 14,000 / 9.5 = 1,473 Watt of power will be consumed. All consumed power will become waste heat. 1,473 Watt will become 1,473 x 3.412 = 5,028 BTU (per hour) waste heat. Tip: For a 9.5 EER unit, the wasted heat is almost exactly 30% of the BTU number.

Here is a quote from ConsumerReports.org 2008 .

While portable A/Cs might be convenient, those we tested delivered only about half of their cooling capacity—that means they operated with an energy-efficiency ratio (EER) of about 5 or 6. Compare that with the minimum EER of just under 10 for the window air conditioners we’ve recently test (we tested window models with an EER as high as 12).

Central air units and window units have most of this power consumed outside the window and the waste heat is dissipated to the outside air. A portable A/C has all the power consumed inside the house. All consumed power turns to about 30% more heat that has to be removed from the room. This percentage will go higher for a lower EER unit or for a portable air conditioner whose EER has dropped because blocked air flow or dust on the coils.

Warning on exhausting cool air out of the room

Another hidden problem is inherent with single hose portable air conditioners. They suck air from the room and dump it outside. Besides cooling, a single hose portable A/C creates a vacuum for the room it is in. The vacuum may not be measurable if the room is not air-tight. The more air-tight the room is the higher the vacuum will be.

portable-air-conditioner-flow-diagramThe vacuum enable air from elsewhere to leak into the room for the same amount as the exhausted air, as shown in this picture. If the air is leaked in from outside, it will be humid and hot. If the air is from other rooms of the house, outside hot air will leak into those rooms. So, we may get some cooling near the portable A/C but more heat and humidity will come to the house, as seen in this image.

The tricky thing is that it may take an hour or two to vacuum out the cool air from the surrounding rooms. In the first couple hours, we may feel pretty good about the A/C. We may never thought the other rooms are getting hotter because the use of a single hose air conditioner. That is why we put the word “Warnings” in the title of this article.

To be fair, due hose portable air conditioners do not have this problem. The trade-off is another hose. These hoses will be vibrating in use and could break easily. Any leak in these hoses or their connections will result in dumping room air outside in the same manner as a single hose portable A/C.

The more leaks, heat leaks or air leaks, to the room the more heat need to be removed from the room. Hence, the higher BTU rating is needed. To achieve the same amount of cooling, a single hose portable air conditioner needs a substantially higher BTU rating. The higher the BTU rating, the more power an air conditioner will consume. All the consumed power will turn into heat. That heat also needs to be exhausted through the hose for a portable air conditioner. More heat needs a bigger fan to drive more air out the hose. A bigger fan turns more power to waste heat inside the house.

Warning about condensate, noise, and space

Portable-Air-Conditioner-Condensate-RemovalAs air is cooled, moisture in the air will condense to water. A portable air conditioner may fill its condensate tank quickly in a humid day. Watch out for condensate overflow or drips. Tip: When buying a portable A/C, check if it has the feature to evaporate the condensate with the exhaust air like shown in this image. In comparison, a window air conditioner is designed to have its condensate pan tilted down towards the outside. Any condensate will flow to the outside half of the air conditioner. The condensate evaporate into the hot outside air without being noticed most of the time.

The most noisy part of an A/C is the compressor. For central air unit, the compressor is in the outside unit. For window unit, the compressor is outside the window. For the portable air conditioner, the compressor is inside the room in the cooled area. The compressor is also bigger because of the higher BTU rating cited above. Any loose parts like the hoses could resonant and amplify the noise. Tip: A soft pad under the unit will reduce the noise.
portable-air-conditioner-installation
A portable air conditioner need about 18 inches of space on each side for it to breath as shown in this image of an installation guide. Put your hand about that distance away from the unit, if you feel air flow though your hand, that place should be open for air flow. Any blockage of air flow to or from the unit will lower the EER and reduce the cooling. Do not put the unit too close to a wall, a sofa, or a bed. Make sure you have the space before you buy the unit.Tip: To achieve the full EER, a portable air conditioner need a lot more space than its physical dimensions.

Conclusion

BTU rating is the amount of heat an air conditioner can remove from a room. For a duel hose portable A/C, about 30% of that heat is the waste heat produced by the unit itself. For single hose portable air conditioner, about 50% of that heat is produced by the unit or sucked in by the unit from outside the house. In comparison, a window unit or a central air unit only has waste heat from the indoor fan for removal that could be less than 5%.

Attachments:


2008 Standard for Performance Rating of Unitary Air-Conditioning &a...
Cooling Load Calculations and-Principles

Views: 206560

Tags: About, Air, Conditioners, EER, Portable, Warnings, air, condensation, conditioner, cooling, More…efficiency, energy, exhaust, heat, home, hose, rating, summer, waste

Comment

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

Comment by Michael Berg on June 29, 2014 at 9:56pm

I recently purchased a single hose portable 5000 btu a.c. for a small enclosed 100 sq ft room inside my garage.  I am having a heck of a time controlling the humidity in both "a.c." and "dry" mode.  The temperarture drops nicely but according to my hygrometer, I will start out at approx 42% humidity and as the a.c runs, the humidity shoots up to 65-70%. after I experienced the high humidity  I have sealed up the room so well that due to the vacuum it is difficult to open the door into the room.  I have a fan circulating air inside also but without running a separate dehumidifier in the room, the humidity is still high.  I am getting virtually nothing from the external hose when in "dry" mode but the dehumidifier will need to be emptied every 8 hours.  I don't have a window in the room so I drilled a hole in the side of the house to exhaust the warm air, but did use the window kit that came with the unit.  There are no leaks in the hose or the connection with the hose to the wall mount.  I thought that the room was not getting enough air so I have cracked the door a tad with the garage door closed and after several hours the humidity is still high.  I am not sure what to do at this point as I am trying to avoid running the dehumidifier and a.c. at the same time to reduce humidity.  I will say that the pan in the bottom of the unit does gather plenty of water but is recycled and shouldn't need to be emptied.  I am hoping someone could offer some advice.  Thank you.    

Comment by elizabethreilly on June 25, 2014 at 4:28am

The information provided is really helpful to understand the concept whereas people mostly miss out simple things like cleaning air ducts which helps to inhale the fresh air.

https://plus.google.com/103587002729772197042/about

Comment by Nancy shirley on May 29, 2014 at 5:44am

Portable air conditioners are one off the most usable home appliances. Such type of ac's usually takes a small amount of money to consumed. Noise is the most common problem portable ac's have. But there are several of the excellent brands too who have noise free units as the size increase the chances of noise also increase. 

Comment by David Kerrigan on April 2, 2014 at 3:47pm

I agree with you here, but wanted to add the fact that a portable air conditioner can be utilized very effectively such as cooling your bedroom at night or home office during the day while keeping the rest of the windows in the house open. You would be amazed how much energy this can save over the course of the month.

 - David from Coolaer.com

Comment by Bob Blanchette on July 5, 2013 at 6:19pm

Ever notice that Portable AC's are exempt for posting EER on the box?

Comment by Perry Ning on July 5, 2013 at 12:56pm

Hi Adam, Thank you for the comment.  Have a nice summer!  Perry

Comment by Adam brown on July 5, 2013 at 9:06am

Hi Perry

Very factual and informative post on portable AC!! 

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.

Latest Activity

Mike Braun just added their location.
(via Member Map)

18 minutes ago
Bud Poll replied to Bud Poll's discussion Another benefit from air sealing
"From my work in NY City many years ago, the critters I saw would never have fit through a quarter…"
3 hours ago
Barbara Smith replied to Bud Poll's discussion Another benefit from air sealing
"Eliminating quarter sized holes can impede rats from entering a building, in areas where rats tend…"
4 hours ago
Casey Murphy is now a member of Home Energy Pros
5 hours ago
Walter Ahlgrim replied to James White's discussion What happened to Home Energy Pro's website?
"Try downloading Google Chrome web browser https://www.google.com/chrome/browser/ I had similar…"
21 hours ago
Stacy Hunt posted an event

Building America Webinar: Multifamily Ventilation Strategies and Compartmentalization Requirements at Virtual

September 24, 2014 from 3pm to 4:30pm
The Building America Program is hosting a no-cost, webinar-based training on Multifamily…See More
22 hours ago
Ben Jacobs replied to Bud Poll's discussion Another benefit from air sealing
"This is info I give to clients that I serve. People who live in homes that are not energy efficient…"
yesterday
Brennan Less replied to Bud Poll's discussion Another benefit from air sealing
"Thanks Bud. I just feel the need to point out any such issues, because we as a field need to be…"
yesterday

© 2014   Created by Lawrence Berkeley National Laboratory.