Dale Stephens's Blog – December 2012 Archive (3)

Window Replacement - wading through the maze of options and sales

Background:

In 2012 we decided it was time to replace our 27-year old contractor grade double paned aluminum widows. Some of the seals had failed. Some of the window were leaking (water).

We planned to replace 19 windows initially and ended up replacing 21 in total. 11 of which were single-hung 3-0x6-0 that we replaced with double hung windows. Three had arched eye-brows and had to remain single-hung.

From my online research I was…

Continue

Added by Dale Stephens on December 11, 2012 at 9:08am — 1 Comment

LED Lighting - Garage Door opener interference

Background

In November 2012 I started replacing all CFL and Incandescent lighting in the home with new LED bulbs. At our local 'big box' home improvement store I purchased several (35) LED bulbs and began making the switch to LEDs. Over the past several years most of our incandescent lights had been replaced with CFLs. I was not happy with the performance of the CFLs both in terms of light quality and life of the bulb. It seems like every other month I was…

Continue

Added by Dale Stephens on December 11, 2012 at 6:30am — 6 Comments

Home Energy Improvements 2012 in Plano, Texas

During the past 12 months (2011/2012) we have completed several energy efficiency and other projects in our home in Plano, Texas.

Background:

Brick Veneer, slab on grade home built in 1985.

Living           1938 sq. ft.

Under Roof   2560 sq. ft.

Home faces Southeast. All rooms have ceilings above 8' with ceiling treatments (vaulted, boxed, splayed,). Home built with 24 contractor-grade windows mostly 3-0x6-0. Home…

Continue

Added by Dale Stephens on December 11, 2012 at 5:30am — No Comments

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.

Latest Activity

Hal Skinner replied to Tony Rigdon's discussion Placement of 5/8" firewall, over or under foam board insulation?
"I am curious now.  They require a penetration firewall in the wall system but do not require a…"
2 hours ago
Mike Kandel posted discussions
2 hours ago
Mike Kandel added 2 discussions to the group Building Performance Institute (BPI)
2 hours ago
Hal Skinner replied to Tony Rigdon's discussion Placement of 5/8" firewall, over or under foam board insulation?
"WOW.  30 years working and m,eeting with every kind of contractor and never heard of this…"
3 hours ago
Tony Rigdon replied to Tony Rigdon's discussion Placement of 5/8" firewall, over or under foam board insulation?
"The building inspector when he inspected my footing told me about the drywall on the outside being…"
5 hours ago
Profile IconSuskin Lockett Jr, Yoomie Ahn, Lindy Wordlaw and 6 more joined Home Energy Pros
5 hours ago
Tony Rigdon replied to Tony Rigdon's discussion Placement of 5/8" firewall, over or under foam board insulation?
"Bud, I'm in Columbia, MO so Zone 4 Mixed Humid. I had never heard about drywall on the outside…"
5 hours ago
Sean Lintow Sr replied to Tony Rigdon's discussion Placement of 5/8" firewall, over or under foam board insulation?
"I am pretty sure he is talking about using commercial drywall designed for this type of purpose and…"
8 hours ago

© 2014   Created by Lawrence Berkeley National Laboratory.