Christopher Cadwell's Blog – December 2011 Archive (2)

Part 2 of: The "1-2 Punch" to HVAC "Not Understoods"

Proper sizing of HVAC equipment is smaller, and smaller means more comfort.

Probably the usual thought in the HVAC industry by technicians is that the units need to be made bigger for comfort. Perhaps this comes from the idea of coming home from work, and needing a set back thermostat to do its magic, and get the home comfortable fast,…

Continue

Added by Christopher Cadwell on December 13, 2011 at 8:30am — 4 Comments

Part 1 of: The "1-2 Punch" to HVAC "Not Understoods"

HVAC Delivery System Losses -

This is the Air Pressures, Duct System, the Boots, the Registers, Equipment Cabinets, Air Balancing, Temperature rise and drop parameters, etc. 

 

This is a greatly overlooked and not understood part of a system, even by most HVAC Journeymen and contractors. How do we come to this conclusion?…

Continue

Added by Christopher Cadwell on December 1, 2011 at 10:04am — 1 Comment

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.  Home Energy Pros is sponsored by the Better Buildings Residential Network.

Latest Activity

Dale Pickard replied to Rod Fox's discussion Does altitude affect AFUE? or just the input/output BTUs?
"Hans, The car manufacturer's are doing it with mass flow sensors and oxygen sensors…"
4 hours ago
Dale Pickard replied to Rod Fox's discussion Does altitude affect AFUE? or just the input/output BTUs?
"I was trying to avoid naming manufacturers, but I was going by the published information for the…"
5 hours ago
Eric Kjelshus replied to Rod Fox's discussion Does altitude affect AFUE? or just the input/output BTUs?
"I look at this not about AFUE,  but flue gas dewpoint.  If your burn rate is rotting the…"
7 hours ago
Bob Blanchette replied to Kirsten Richnavsky's discussion Crawl spaces and attics: OSHA to implement new rule on confined spaces
"Keeping HVAC equipment out of attics should be part of the new code. "
8 hours ago
Linda Wigington replied to Linda Wigington's discussion Weigh in - Honorable Mention? 2nd Base? Half-Way There? 50% Better? On the Path? in the group 1000 Home Challenge
"Nickie -  Good points. I think it is easy enough to flag or designate projects that achieve…"
9 hours ago
Morgan M Audetat replied to Rod Fox's discussion Does altitude affect AFUE? or just the input/output BTUs?
"Though Viessmann is relatively unique in the application of Lambda technology to condensing…"
10 hours ago
Lars olsen posted a blog post
18 hours ago
Eric Kjelshus replied to Rod Fox's discussion Does altitude affect AFUE? or just the input/output BTUs?
"The heat exchanger gets burnt out, if presser is to high or if mix is to rich, then I see holes in…"
yesterday

© 2015   Created by Lawrence Berkeley National Laboratory.