Christopher Morin's Blog – August 2014 Archive (3)

Top 5 Changes to ACCA Manual S

      As I had brought up years ago, ACCA's Manual S was in dire need of an update.  Written in 1995, Manual S Residential Equipment Selection was passed by with huge technical and efficiency strides within the…

Continue

Added by Christopher Morin on August 27, 2014 at 5:30pm — 1 Comment

UPDATED: Big Changes for Duct Testing in MA

   If you have not been asked to complete a duct test by your local Massachusetts Inspector, it is just a matter of time before you are surprised by this stringent/updated code requirement.  Despite some push-back from Contractors  and Inspectors, all of MA is required to test new or altered duct systems.  All of MA adopted the 2012 International Energy…

Continue

Added by Christopher Morin on August 17, 2014 at 4:59pm — 9 Comments

No Bubbles, No Troubles!

Or is there? This saying is an old adage in our industry to let the technician know that the refirgerant charge is "all set". You see, there must be a steady stream of liquid to the metering device for it to function properly. For sake of conversation, let's use the TXV. In order for most TXV's to throttle and correctly maintain the desired Superheat, there must be a minimum of 2F of subcooled liquid at the valve (not where it is measured, near the condenser). If the liquid were to flash off… Continue

Added by Christopher Morin on August 12, 2014 at 1:19pm — No Comments

Videos

  • Add Videos
  • View All

Twitter

Latest Activity

Laurie DiDonato updated an event
Thumbnail

Become a HERS Rater with the NE HERS Alliance this fall! at Classroom Component at Energize Connecticut Center

September 19, 2016 at 9am to October 21, 2016 at 5pm
Online Component: September 19th-30th - Weekdays 9am-12pm5-Day Classroom/Field Training:October…See More
44 minutes ago
Melissa Baldridge posted a discussion

IECC 2012 & 2015 Compliance & HRVs

 I’m failing IECC 2012 with the HRVs we’ve been using – Honeywell .  (See specs below that I…See More
1 hour ago
Chris Woods replied to Steve Mann's discussion Eliminator EF400 Smoke Machine in the group Energy Auditing Equipment for Sale, Trade or to Purchase
"Is this still available?"
1 hour ago
Melissa Baldridge replied to Melissa Baldridge's discussion ENERGY STAR - Slab Insulation
"Thanks, John.  That's helpful.  And yes - I've seen projects with perimeter…"
1 hour ago
Jan Green commented on Diane Chojnowski's group Facebook Pages
"Great to see FB pages here!   "
2 hours ago
Brett Little replied to Rob Madden, Solar Home Broker's discussion Indoor Air Quality Monitors and Meters
"Great! Email me at Brett.Little@greenhomeinstitute.org"
4 hours ago
Quinn Korzeniecki replied to Larry Nissman's discussion Foam insulation on attic floor
"I'll send you a message on here for more details. Keep an eye on your inbox!"
5 hours ago
Larry Nissman replied to Larry Nissman's discussion Foam insulation on attic floor
"Hi Quinn. I'm first trying to find out if this is considered a bad insulation installation.…"
5 hours ago