Duct Gains: Why do we hate R-8?

Ever since the adoption of the 2009 International Residential Energy Conservation Code (IECC), duct sealing efforts have been tested using the total leakage or leakage to outdoors methods.  It really is amazing how much duct gains effect the operation of your equipment and the comfort of your customer.  The missing part of "duct testing" appears to be how well the ducts are insulated.  Sure, you are required to use R-8 insulation on supply ductwork when located outside the building envelope,…

Continue

Added by Christopher Morin on June 26, 2012 at 1:13pm — 1 Comment

Site Survey: Windows & SHGC

  When completing your site survey for Manual J Load Calculations, significant time can (or should) be spent identifying window values.  Did you know that most windows these days come with an NFRC rating, a tag located in the window jam that you can reference on NFRC.org? This identification number can tell you important details like window coatings, u-value, light transmittance, air leakage, and solar heat gain coefficients (SHGC).  Not identifying the correct values can sway your load…

Continue

Added by Christopher Morin on June 10, 2012 at 6:34pm — 2 Comments

Heat Pump Break-Even COP's

How do you know if  should upgrade your air-conditioner to a heat-pump and create a dual-source application during replacement this Summer?  I personally always prefer the option of multiple fuel sources, particularly since energy prices have been all over the place during the last decade.  Fortunately, based on average energy prices, there is some simple math to figure out if an aggressive assessment should be made for a dual-source heat pump application, based on equations from ACCA's…

Continue

Added by Christopher Morin on June 3, 2012 at 12:23pm — 5 Comments

Videos

  • Add Videos
  • View All

Twitter

Latest Activity

Hans Joachim Preiss replied to Dan Antonioli's discussion Net Zero Energy Hot Water
"Dan, Let me attempt to compare apples with apples: My solar thermal system is located in…"
7 minutes ago
Dan Antonioli replied to Dan Antonioli's discussion Net Zero Energy Hot Water
"Hi Hans, I don't know where you're located but where I am a 2.5 kw pv system costs closer…"
2 hours ago
Hans Joachim Preiss replied to Dan Antonioli's discussion Net Zero Energy Hot Water
"I use the combination of solar PV and heatpump water heaters in the vast majority of net-zero…"
4 hours ago
Amber Vignieri posted a blog post
8 hours ago
William Zwack added a discussion to the group Job Board
Thumbnail

Residental Energy Specialist: Washington, DC (or possibly telework)

Position Summary: CSRA Incorporated is searching for a Sr. Residential Building Energy Efficiency…See More
9 hours ago
Profile Iconteplie_poly, Gabriel Lieb and Beth Neri joined Home Energy Pros
9 hours ago
Shaun posted a discussion

Commercial duct testing

Hello all,I am a BPI BA, HERS rater and QC inspector. I cant find a ton of information on this…See More
9 hours ago
Dennis Heidner replied to Dan Antonioli's discussion Net Zero Energy Hot Water
"Dan, Solar PV and solar H2O work in northern climates...They can still provide the desired goal in…"
23 hours ago

© 2016   Created by Lawrence Berkeley National Laboratory.   Powered by

Badges  |  Report an Issue  |  Terms of Service