Christopher Morin's Blog – June 2012 Archive (3)

Duct Gains: Why do we hate R-8?

Ever since the adoption of the 2009 International Residential Energy Conservation Code (IECC), duct sealing efforts have been tested using the total leakage or leakage to outdoors methods.  It really is amazing how much duct gains effect the operation of your equipment and the comfort of your customer.  The missing part of "duct testing" appears to be how well the ducts are insulated.  Sure, you are required to use R-8 insulation on supply ductwork when located outside the building envelope,…

Continue

Added by Christopher Morin on June 26, 2012 at 1:13pm — 1 Comment

Site Survey: Windows & SHGC

  When completing your site survey for Manual J Load Calculations, significant time can (or should) be spent identifying window values.  Did you know that most windows these days come with an NFRC rating, a tag located in the window jam that you can reference on NFRC.org? This identification number can tell you important details like window coatings, u-value, light transmittance, air leakage, and solar heat gain coefficients (SHGC).  Not identifying the correct values can sway your load…

Continue

Added by Christopher Morin on June 10, 2012 at 6:34pm — 2 Comments

Heat Pump Break-Even COP's

How do you know if  should upgrade your air-conditioner to a heat-pump and create a dual-source application during replacement this Summer?  I personally always prefer the option of multiple fuel sources, particularly since energy prices have been all over the place during the last decade.  Fortunately, based on average energy prices, there is some simple math to figure out if an aggressive assessment should be made for a dual-source heat pump application, based on equations from ACCA's…

Continue

Added by Christopher Morin on June 3, 2012 at 12:23pm — 5 Comments

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.

Latest Activity

Stacy Hunt posted events
1 hour ago
Rob Madden, Solar Home Broker posted blog posts
1 hour ago
Rob Madden, Solar Home Broker posted a photo
1 hour ago
Kerry Haglund posted a blog post

Efficient Windows Collaborative Releases Window Selection Tool Mobile App

The Efficient Windows Collaborative (EWC) has released a mobile app based on it web-based Window…See More
2 hours ago
Casey Gesell posted a video

Home Comfort Pays for Itself | Ideas Worth Sharing

http://www.myhomescience.com There are 88 million homes in the U.S. and Canada alone that burn twice as much fuel for heating and electricity for cooling tha...
5 hours ago
Profile IconRob Madden, Solar Home Broker, Alicia Hobbs, Rachel Scott and 2 more joined Home Energy Pros
6 hours ago
Don Fitchett posted a video

HVAC AC Compressors Training

This HVAC training sample is from the HVAC section of the Online Industrial Training Video Library (http://bin95.com/Industrial-Training-Videos/HVAC-Training...
6 hours ago
Sean Lintow Sr replied to Robert Cameron's discussion Air duct testing questions.
"#1 - outside "conditioned" space & really should not be allowed #2 - up to the AHJ if…"
8 hours ago

© 2014   Created by Lawrence Berkeley National Laboratory.

Badges  |  Report an Issue  |  Terms of Service