Christopher Morin's Blog – June 2012 Archive (3)

Duct Gains: Why do we hate R-8?

Ever since the adoption of the 2009 International Residential Energy Conservation Code (IECC), duct sealing efforts have been tested using the total leakage or leakage to outdoors methods.  It really is amazing how much duct gains effect the operation of your equipment and the comfort of your customer.  The missing part of "duct testing" appears to be how well the ducts are insulated.  Sure, you are required to use R-8 insulation on supply ductwork when located outside the building envelope,…

Continue

Added by Christopher Morin on June 26, 2012 at 1:13pm — 1 Comment

Site Survey: Windows & SHGC

  When completing your site survey for Manual J Load Calculations, significant time can (or should) be spent identifying window values.  Did you know that most windows these days come with an NFRC rating, a tag located in the window jam that you can reference on NFRC.org? This identification number can tell you important details like window coatings, u-value, light transmittance, air leakage, and solar heat gain coefficients (SHGC).  Not identifying the correct values can sway your load…

Continue

Added by Christopher Morin on June 10, 2012 at 6:34pm — 2 Comments

Heat Pump Break-Even COP's

How do you know if  should upgrade your air-conditioner to a heat-pump and create a dual-source application during replacement this Summer?  I personally always prefer the option of multiple fuel sources, particularly since energy prices have been all over the place during the last decade.  Fortunately, based on average energy prices, there is some simple math to figure out if an aggressive assessment should be made for a dual-source heat pump application, based on equations from ACCA's…

Continue

Added by Christopher Morin on June 3, 2012 at 12:23pm — 5 Comments

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.

Latest Activity

Patrick Carter replied to Patrick Carter's discussion Minneapolis Blower Door & Test Equipment for Sale! in the group Energy Auditing Equipment for Sale, Trade or to Purchase
"As of yesterday 09/19/2014, the equipment has been sold..."
9 hours ago
Hal Skinner replied to Hal Skinner's discussion An example of what an RCC can do with no R- insulation in the walls.
"Mornin Brett. 90 to 85, yes a slight variance there.  Same ASTM test, different scientists,…"
yesterday
Bret Curry replied to Hal Skinner's discussion An example of what an RCC can do with no R- insulation in the walls.
"Great information Hal. It appears the thermal emissivity in your test was .85 rather than .90. Are…"
yesterday
Juan Roca commented on Dale Stephens's blog post LED Lighting - Garage Door opener interference
"Hi,There is a real problem with remote controls and LED lights. However, there is a solution in the…"
yesterday
Profile IconJuan Roca and Elizabeth Coe joined Home Energy Pros
Thursday
Casey Gesell posted videos
Thursday
Gerald Shechter posted videos
Thursday
Hal Skinner replied to Hal Skinner's discussion An example of what an RCC can do with no R- insulation in the walls.
"Bret,  here are the 2 reports I referred…"
Thursday

© 2014   Created by Lawrence Berkeley National Laboratory.

Badges  |  Report an Issue  |  Terms of Service