Technical Tape Desecration

Lets face it – building science is pushing the performance of adhesive tapes to a new levels and though I can’t profess to have my daughters’ ability in making fashionable duct tape purses,  I have been know to mis-apply good tape to get me out of a bind! I think Red Green would be impressed!

If you send me your photos, I…

Continue

Added by Greg Labbe on July 22, 2014 at 8:33am — 1 Comment

New Air Tightness Record in Ontario (Dare I say Canada?)

It happened again yesterday: a new record (tell me if you know of a tighter house in Ontario if not Canada!) for air tightness was broken in Oakville by Certified Passive House Consultant (CPHC) Ed Marion of Passive House Ontario.

And this was just a pre-drywall test, so it can only get better from here.…

Continue

Added by Greg Labbe on May 6, 2014 at 1:51pm — 5 Comments

A call to Builders and Architects: Does the Homeowner Know You’re a Blowerdoor Virgin?

When setting out to build an efficient house, the elephant in the room is air tightness. Industry is resisting mandated air tightness testing if thresholds are introduced meanwhile building codes are ratcheting up efficiency on all fronts except air tightness. Having debunked the myth that “a house needs to breath” its becoming painfully obvious to any building scientist that the lowest hanging fruit on the efficiency tree isn’t geothermal but simply producing a more air tight…

Continue

Added by Greg Labbe on April 9, 2014 at 5:30am — No Comments

Air Leakage Testing a New Off-Grid High Performance House

We had the great pleasure of air leakage testing a new off-grid, high performance house last week. It was the most air tight building we’d ever tested!

DSC_0524

Situated on a hill overlooking the sweep of the Saugeen River below.

Builder Steven…

Continue

Added by Greg Labbe on November 12, 2013 at 11:30am — 2 Comments

Tucking a garage under the second floor is a common practice, but is it a GOOD one?

As the price of land edges up, the practice of tucking a garage under the second floor of a house is common practice, but is it good practice? The bedroom above the garage has earned the moniker of “The Bonus Room” as it tends to be the most troublesome room in the house with the most comfort complaints from home owners.

 …

Continue

Added by Greg Labbe on October 28, 2013 at 3:30pm — 3 Comments

Spot the Design Weakness - For Northern Climates

If we had a dime for each weak building assembly detail we saw, we’d be rich. In our 14 years of diagnosing comfort problems for clients; the exposed floor ranks as one of the most stark discomfort features of a home, new or old.

Walking home from the coffee shop Sunday and came across the feature below. Have a look at the photo and see how many design errors you can pick out:…

Continue

Added by Greg Labbe on October 22, 2013 at 7:49pm — 11 Comments

Quickest way to Field-check you Model 3 Flow Sensor!

I think the question I get asked the most is, well I dunno know, it happens a lot, enough that I would remark on it – a lot of people come up to me and they say “How do I know if my flow sensor is positioned within spec?“

My answer’s always the same, I say: “Listen. Luckily we don’t have to go all the way back to the Civil War to answer this…” ¹

The truth is, most never check, but here’s a quick easy way to ensure your Minneapolis fan’s flow sensor’s positioned properly in the…

Continue

Added by Greg Labbe on September 30, 2013 at 7:59am — No Comments

Good Drainage Planes stop Capillary Action

We use drainage gaps or planes in wall systems to stop water from entering the building shell and causing deterioration or mould. This air gap does two things if wide enough; it prevents water’s surface tension from staying or even climbing up the wall and the gap also disperses the forces of wind driven rain or solar vapour drive. Let’s look at…

Continue

Added by Greg Labbe on April 22, 2013 at 11:00am — No Comments

When do I do the air leakage test?

Thankfully more and more new homes in Ontario are being 3rd party airtightness tested. Some do it to comply with EnerGuide80, some builders want to distinguish their build quality by having it ‘pass’ an air test or to meet a branded standard like EnergySTAR and many, surprisingly, still don’t get tested at all. Understandably many builders and architects are nervous about…

Continue

Added by Greg Labbe on February 5, 2013 at 5:12am — No Comments

Videos

  • Add Videos
  • View All

Twitter

Latest Activity

Crosbey Archery liked Crosbey Archery's blog post How to improve the air quality in your home ?
yesterday
Crosbey Archery replied to Don Hynek's discussion Testing "Magic Pak" units?? in the group Multifamily Buildings
"second-floor (and higher) units without humping a ladder all the way around the building is a very…"
yesterday
Colin Genge posted events
yesterday
Profile IconJon Turnbaugh, Lights N More and John Kamas joined Home Energy Pros
yesterday
Amber Vignieri posted a blog post

Relay Network Targets Multifamily Housing Upgrades Nationwide

Affordable apartment buildings are home to more than 10 million American households, making them a…See More
yesterday
Tom White's video was featured

Robby Schwarz on Builder Collaboration

Hear Robby Schwarz, of EnergyLogic discuss the value Owens Corning brings to Thrive Home Builders.
yesterday
Crosbey Archery liked Don Hynek's discussion Testing "Magic Pak" units??
yesterday
Crosbey Archery joined Norm Bourassa's group
Thumbnail

Multifamily Buildings

For too long there has been relatively little EE focus on multifamily, but some new programs have…See More
yesterday

© 2016   Created by Lawrence Berkeley National Laboratory.   Powered by

Badges  |  Report an Issue  |  Terms of Service