All Blog Posts Tagged 'infiltration' (2)

New Energy Code in Massachusetts

In July 2013, the State Board of Building Regulations and Standards (BBRS) voted to adopt the 2012 International Energy Conservation Code (2012 IECC) and ASHRAE 90.1-2010 with MA amendments as the new baseline energy code. The BBRS allowed for the new regulations to run concurrently with the current energy regulations until July 1, 2014. During that time, either set of energy regulations could be used when applying for…

Continue

Added by Everblue Training on October 8, 2014 at 6:56am — No Comments

Willowside Rd., Day 14

John and Jane Doe's report is basically written. I have a template that I use that has been slowly built and improved over the past projects. It's a fine start but still requires a fair amount of custom writing, since each house has enough unique issues that need to be addressed.  There's report software out there such as Recurve's, EAI, or BizEE, but none have that personal touch that comes from a written report.  So here's some items from the report:





Target Infiltration: 0.25… Continue

Added by David Willson on April 26, 2011 at 8:30pm — 4 Comments

Monthly Archives

2015

2014

2013

2012

2011

2010

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.

Latest Activity

John Nicholas replied to William Fisher's discussion Can tankless water heaters provide hot water even when the groundwater is fairly cold?
"Simple math will tell you.   Figure the GPM requirements for each fixture you think will run…"
1 hour ago
R Higgins replied to William Fisher's discussion Can tankless water heaters provide hot water even when the groundwater is fairly cold?
"I have that problem, 45 to 50 degree ground water, in summer, not that we have much of a…"
10 hours ago
R Higgins replied to Larry Schaffert's discussion How to correctly insulate exterior wall in a 1900 house?
"I'd suggest trying to replicate the existing conditions as much as possible in your rebuild,…"
10 hours ago
Bryan Pringle replied to Bryan Pringle's discussion Dense packed cellulose in basement?
"I am getting a lot of "bad idea" push back on this.  I fully understand that…"
22 hours ago
Greg Mitchell commented on Larry Ralph Jr's blog post Top 7 Worst Crawl Space Repairs
"Spray Foam should be used in crawlspaces.   To learn about closed cell foam in crawlspaces…"
22 hours ago
Jerry Lawrence posted events
yesterday
Morgan M Audetat replied to Bryan Pringle's discussion Dense packed cellulose in basement?
"Right you are. You have to ask: what will the cellulose contribute.  Here in Minneapolis we…"
yesterday
Morgan M Audetat replied to Tony Hicks's discussion Slab-on-grade Insulation
"All slabs float. We have been installing radiant floors on various slab constructions since the…"
Friday

© 2015   Created by Lawrence Berkeley National Laboratory.

Badges  |  Report an Issue  |  Terms of Service