All Blog Posts Tagged 'EnergyPro' (1)

Willowside Rd., Day 10, part 2

OK, I'm back from getting the dimensions of Doe's house, enter all the information into EnergyPro, and do an initial calculation. It looks like the house as it is has a HERS of 147, which means that the model predicts that it will use about one and a half times as much energy as a 'reference home', which is this exact same home if it was built to today's energy code requirements and has by definition a HERS of 100. 147 is not too bad but way above what we want. Let's see if we can get it below… Continue

Added by David Willson on April 25, 2011 at 8:30pm — No Comments

Latest Blog Posts

Most Popular Blog Posts

Monthly Archives

2015

2014

2013

2012

2011

2010

1999

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.  Home Energy Pros is sponsored by the Better Buildings Residential Network.

Latest Activity

Dale Pickard replied to Rod Fox's discussion Does altitude affect AFUE? or just the input/output BTUs?
"Hans, The car manufacturer's are doing it with mass flow sensors and oxygen sensors…"
2 hours ago
Dale Pickard replied to Rod Fox's discussion Does altitude affect AFUE? or just the input/output BTUs?
"I was trying to avoid naming manufacturers, but I was going by the published information for the…"
3 hours ago
Eric Kjelshus replied to Rod Fox's discussion Does altitude affect AFUE? or just the input/output BTUs?
"I look at this not about AFUE,  but flue gas dewpoint.  If your burn rate is rotting the…"
5 hours ago
Bob Blanchette replied to Kirsten Richnavsky's discussion Crawl spaces and attics: OSHA to implement new rule on confined spaces
"Keeping HVAC equipment out of attics should be part of the new code. "
6 hours ago
Linda Wigington replied to Linda Wigington's discussion Weigh in - Honorable Mention? 2nd Base? Half-Way There? 50% Better? On the Path? in the group 1000 Home Challenge
"Nickie -  Good points. I think it is easy enough to flag or designate projects that achieve…"
7 hours ago
Morgan M Audetat replied to Rod Fox's discussion Does altitude affect AFUE? or just the input/output BTUs?
"Though Viessmann is relatively unique in the application of Lambda technology to condensing…"
8 hours ago
Lars olsen posted a blog post
16 hours ago
Eric Kjelshus replied to Rod Fox's discussion Does altitude affect AFUE? or just the input/output BTUs?
"The heat exchanger gets burnt out, if presser is to high or if mix is to rich, then I see holes in…"
yesterday

© 2015   Created by Lawrence Berkeley National Laboratory.