Cameron Millard's Blog Posts Tagged 'Direct' (1)

90% AFUE Wall Mount Furnace

I run an energy program in the mountains of Colorado. We have a lot of homes without existing duct work and older style wall-mounted furnaces. I've been looking for a decent upgrade choice for my clients - so far Rinnai seems to be the brand of choice for most heating contractors.  Problem is they have an AFUE of only .82 at the max, so don't qualify for high-efficiency furnace rebates through our program.  

I recently discovered the Energy Saver 90 Plus from Empire Heating, a…

Continue

Added by Cameron Millard on February 26, 2014 at 7:54am — 6 Comments

Latest Blog Posts

Most Popular Blog Posts

Monthly Archives

2014

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.  Home Energy Pros is sponsored by the Better Buildings Residential Network.

Latest Activity

Dale Pickard replied to Rod Fox's discussion Does altitude affect AFUE? or just the input/output BTUs?
"Hans, The car manufacturer's are doing it with mass flow sensors and oxygen sensors…"
12 hours ago
Dale Pickard replied to Rod Fox's discussion Does altitude affect AFUE? or just the input/output BTUs?
"I was trying to avoid naming manufacturers, but I was going by the published information for the…"
13 hours ago
Eric Kjelshus replied to Rod Fox's discussion Does altitude affect AFUE? or just the input/output BTUs?
"I look at this not about AFUE,  but flue gas dewpoint.  If your burn rate is rotting the…"
15 hours ago
Bob Blanchette replied to Kirsten Richnavsky's discussion Crawl spaces and attics: OSHA to implement new rule on confined spaces
"Keeping HVAC equipment out of attics should be part of the new code. "
16 hours ago
Linda Wigington replied to Linda Wigington's discussion Weigh in - Honorable Mention? 2nd Base? Half-Way There? 50% Better? On the Path? in the group 1000 Home Challenge
"Nickie -  Good points. I think it is easy enough to flag or designate projects that achieve…"
17 hours ago
Morgan M Audetat replied to Rod Fox's discussion Does altitude affect AFUE? or just the input/output BTUs?
"Though Viessmann is relatively unique in the application of Lambda technology to condensing…"
18 hours ago
Lars olsen posted a blog post
yesterday
Eric Kjelshus replied to Rod Fox's discussion Does altitude affect AFUE? or just the input/output BTUs?
"The heat exchanger gets burnt out, if presser is to high or if mix is to rich, then I see holes in…"
yesterday

© 2015   Created by Lawrence Berkeley National Laboratory.