Fluke Thermal Imaging's Blog Posts Tagged 'Baltimore Gas & Electric' (1)

Fluke TiR Featured in new Home Energy Auditing Commercial

Our TiR Thermal Imager was featured in the new Baltimore Gas & Electric home energy inspection commercial! We couldn’t be happier about seeing our signature Fluke-yellow imager featured in this commercial,

which began airing around the greater Baltimore area in late September.



For nearly 200 years, Baltimore Gas & Electric has been meeting the energy needs of Central Maryland, serving more than 1.2 million business and residential electric customers and more…

Continue

Added by Fluke Thermal Imaging on November 15, 2010 at 10:47am — No Comments

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.  Home Energy Pros is sponsored by the Better Buildings Residential Network.

Latest Activity

Eric Kjelshus replied to Rod Fox's discussion Does altitude affect AFUE? or just the input/output BTUs?
"I look at this not about AFUE,  but flue gas dewpoint.  If your burn rate is rotting the…"
17 minutes ago
Bob Blanchette replied to Kirsten Richnavsky's discussion Crawl spaces and attics: OSHA to implement new rule on confined spaces
"Keeping HVAC equipment out of attics should be part of the new code. "
1 hour ago
Linda Wigington replied to Linda Wigington's discussion Weigh in - Honorable Mention? 2nd Base? Half-Way There? 50% Better? On the Path? in the group 1000 Home Challenge
"Nickie -  Good points. I think it is easy enough to flag or designate projects that achieve…"
2 hours ago
Morgan M Audetat replied to Rod Fox's discussion Does altitude affect AFUE? or just the input/output BTUs?
"Though Viessmann is relatively unique in the application of Lambda technology to condensing…"
3 hours ago
Lars olsen posted a blog post
10 hours ago
Eric Kjelshus replied to Rod Fox's discussion Does altitude affect AFUE? or just the input/output BTUs?
"The heat exchanger gets burnt out, if presser is to high or if mix is to rich, then I see holes in…"
21 hours ago
Hans Joachim Preiss replied to Rod Fox's discussion Does altitude affect AFUE? or just the input/output BTUs?
"Good discussion. I came across this comprehensive presentation by Gas Consultants on the effects at…"
22 hours ago
Dale Pickard replied to Rod Fox's discussion Does altitude affect AFUE? or just the input/output BTUs?
"Excellent reply Hans. I think that there isnt' a good general answer to this question but that…"
yesterday

© 2015   Created by Lawrence Berkeley National Laboratory.