Pool Pumps

Started Jan 18, 2012 0 Replies

If the customer has a controller with thier pool equipment, aqualink, jandy, compool most of the better controllers have freeze protection circuits. If the pump runs at night in freeze protection and…Continue

 

mitchell smith's Page

Latest Activity

mitchell smith posted a discussion

Pool Pumps

If the customer has a controller with thier pool equipment, aqualink, jandy, compool most of the better controllers have freeze protection circuits. If the pump runs at night in freeze protection and then runs its regular schedule during the day and it's cold, they could get a whopper utility bill.Try rescheduling the pump controller to turn on at 2am when it's cold and have it run until 6 am. that way it doesn't run twice. If they are on TOu metering, even better.See More
Jan 18, 2012

mitchell smith just added their location.
(via Member Map)

Jan 18, 2012
mitchell smith is now a member of Home Energy Pros
Jan 17, 2012

Profile Information

Company
ducting masters
Professional Certification
BPI

Comment Wall (1 comment)

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

At 1:42pm on January 17, 2012, Diane Chojnowski said…

Hi Mitchell,

Welcome to Home Energy Pros! Feel free to join the conversation in the Forum and Groups. And share your energy efficiency photos, videos and upcoming events. If you're blogging about home performance, this is the place for you!

Don't forget to upload your profile photo. And add your location on our Member Map!


Thanks!
Diane, HEP Moderator

 
 
 

Videos

  • Add Videos
  • View All

Twitter

Latest Activity

Profile IconBrad Cook, Juan M San Miguel, Marla Meyer and 2 more joined Home Energy Pros
10 hours ago
Chris Clay posted photos
15 hours ago
Chris Clay replied to Blake Shurtz's discussion Testing spillage on induced draft furnace?
"Monitor the pressure in the vent, if its positive in the vent for more than a minute it is most…"
16 hours ago
Chris Clay replied to Blake Shurtz's discussion Testing spillage in mechanical closet?
"You can stand outside and read pressures. Be sure to have extra hose as you need CAZ wrt outside…"
16 hours ago
Chris Clay liked Blake Shurtz's discussion Testing spillage in mechanical closet?
16 hours ago
Diane Jackson posted photos
16 hours ago
Amber Vignieri posted a blog post
17 hours ago
Evan Mills commented on Tom White's video
Thumbnail

The Impact of Green Buildings on Cognitive Function

"Good to see work like this going on.  Findings seem qualitatively consistent with what…"
yesterday

© 2016   Created by Lawrence Berkeley National Laboratory.   Powered by

Badges  |  Report an Issue  |  Terms of Service