We are past the point of who's fault is it....
1 Reply

A client had a new double wide set (27x56) in1997 a couple years later had an addition (27x20) to the west side with 27x20 attached garage to that addition, the general contractor tells the client a…Continue

Started this discussion. Last reply by Eric Kjelshus Jan 13.

Implementing ASHRAE 62.2
14 Replies

I work with a C.A.O. here in Ohio under the W.A.P. now that D.O.E. requires implementing ASHRAE 62.2  2010 as of PY 13 and 62.2  2013 in PY 14 my concern is accomplishing this correctly.The…Continue

Started this discussion. Last reply by Thom Knoll Oct 19, 2013.

 

billy g pinnick jr's Page

Latest Activity

billy g pinnick jr commented on Hannah Finch's blog post What Ballerinas and EPros Have in Common...
"I need to correct a previous statement, the BPI course referred to is NOT a CERTIFICATION  but a CERTIFICATE, the course is Building Science Principles."
May 30
billy g pinnick jr commented on Hannah Finch's blog post What Ballerinas and EPros Have in Common...
"RELAX and take them as they come up in conversation. When somebody uses a acronym and your not sure what it stands for, ask. If they aren't willing to explain they're probably not worth talking to anyway. As the event planner you did your…"
May 30
billy g pinnick jr replied to Mike Kandel's discussion Did you know that changes have been made to BPI's BA certification upgrade criteria?
"where can you find anything on the software modeling of energy upgrades? on a webinar 1/17/14  BPI Standards and Certificates there didn't seem to be any programs specified. I asked a question if ORNL's NEAT and MHEA are inline with…"
Jan 23
Eric Kjelshus replied to billy g pinnick jr's discussion We are past the point of who's fault is it....
"The manufacture home has higher SP ( rated Static Pressure) supply and no return  so some are rated to .8 to 1" in water vs most res are .5 in water.  Most Manufacture homes have a little room off the hall way  so the fan is a…"
Jan 13
billy g pinnick jr replied to John Wes's discussion Any good supply distributors in Ohio?
"Blevins (just outside of Dayton) for mobile homes/ Applied Energy for equipment and supplies, I think they are in the Akron area"
Jan 7
billy g pinnick jr's discussion was featured

We are past the point of who's fault is it....

A client had a new double wide set (27x56) in1997 a couple years later had an addition (27x20) to the west side with 27x20 attached garage to that addition, the general contractor tells the client a bigger furnace will be needed. He (general contractor) brings in his HVAC guy who installs a furnace clearly stamped "Installation for site built only", the front of the return box was hacked out to provide for a 16x20 filter plus the back has a run coming off of it into the master bed closet with a…See More
Jan 2
billy g pinnick jr joined Sean Lintow Sr's group
Thumbnail

Best Practices (Residential)

Best Building, Retrofitting, or even Auditing Practices - what are they, what should change, what needs to find it's way to the dust bin of history?See More
Jan 2
billy g pinnick jr joined Tom White's group
Thumbnail

Weatherization

Share your concerns and successes as a weatherization professional, or information for this community.
Jan 1
billy g pinnick jr posted a discussion

We are past the point of who's fault is it....

A client had a new double wide set (27x56) in1997 a couple years later had an addition (27x20) to the west side with 27x20 attached garage to that addition, the general contractor tells the client a bigger furnace will be needed. He (general contractor) brings in his HVAC guy who installs a furnace clearly stamped "Installation for site built only", the front of the return box was hacked out to provide for a 16x20 filter plus the back has a run coming off of it into the master bed closet with a…See More
Dec 14, 2013
Thom Knoll replied to billy g pinnick jr's discussion Implementing ASHRAE 62.2
"In your recent post, Billy, it sounds like you are talking about adjusting the whole-building flow as the local "appendix A" deficit changes, but with the new fan the required flow shouldn't increase; it should have been reduced if…"
Oct 19, 2013
billy g pinnick jr replied to billy g pinnick jr's discussion Implementing ASHRAE 62.2
"A big THANK YOU to everybody responding ! The wealth of untapped knowledge and experience in this field is mind boggling and I urge all of us newbees (only 5yrs here) to utilize this site and others like it to get that knowledge and experience…"
Oct 19, 2013
James Correira replied to billy g pinnick jr's discussion Implementing ASHRAE 62.2
"Thanks Jim, I am familiar with the work done in Wisconsin. Unfortunately we have not advanced that much despite those findings. My suspicion is that as the results of ARRA are being realized, the need to address ventilation is coming to the…"
Oct 18, 2013
Jim Gunshinan replied to billy g pinnick jr's discussion Implementing ASHRAE 62.2
"Hi James and Others in the conversation. I may be biased, because I edit the thing, but Home Energy Magazine has an article by by MARTHA BENEWICZ and ROBERT PARHURST from 2005 about how Wisconsin WAP handled the 62.2 requirements that you…"
Oct 18, 2013
James Correira replied to billy g pinnick jr's discussion Implementing ASHRAE 62.2
"Thanks Bill, This is the type of information that can help drive the funding needed to do the job right the first time. I will share this with my network immediately. Good stuff! "
Oct 18, 2013
bill lazar replied to billy g pinnick jr's discussion Implementing ASHRAE 62.2
" try this:  http://m.npr.org/news/front/174393981 The Community Asthma Initiative has served more than a thousand families over the past seven years. It costs about $2,300 per family — not only for staff time, but also for things…"
Oct 18, 2013
James Correira replied to billy g pinnick jr's discussion Implementing ASHRAE 62.2
"Thanks for weighing in Bill, I am very interested in the Boston Healthy Homes report that you refer to. I was not successful searching the Boston NPR site (WBUR). Please share any other link you may have to this information. While I have no…"
Oct 18, 2013

Profile Information

Company
community action org. delaware,madison,union,logan,champaign,shelby co.s
Professional Certification
BPI Building Analyst,DOE/BPI Quality Control Inspector, State of Ohio Wx Inspector, Warm Choice Inspector

Comment Wall (1 comment)

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

At 2:17pm on October 5, 2013, Diane Chojnowski said…

Hi Billy,

Welcome to Home Energy Pros! Feel free to join the conversation in the Forum and Groups. And share your energy efficiency photos, videos and upcoming events. If you're blogging about home performance, this is the place for you!

Don't forget to upload your profile photo. And add your location on our Member Map!


Thanks!
Diane, HEP Moderator

 
 
 

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.

Latest Activity

Energy Center University posted an event

Better Buildings: Better Business Conferences at Crowne Plaza Chicago O'Hare Hotel & Conference Center and Kalahari Resort and Convention Center

February 26, 2015 to March 13, 2015
Better Buildings: Better Business ConferencesFebruary 26−27, 2015 │ Rosemont, ILMarch 11−13, 2015 │…See More
9 hours ago
Kris Grube added a discussion to the group Job Board
Thumbnail

Good Energy Retrofit, Portland, Or. Hiring Home Performance Salesperson.

Good Energy Retrofit is a small and focused, woman owned and operated, specialty residential…See More
12 hours ago
Benjamin Gromicko posted events
13 hours ago
Nate Adams joined Diane Chojnowski's group
Thumbnail

Hall of Shame

In this group, members share an array of images from the field, showing the kinds of issues…See More
14 hours ago
tedkidd commented on Diane Chojnowski's group Hall of Shame
"Give this thread a bump - here's my "bad" album and some of the…"
15 hours ago
Eric Kjelshus commented on Adam Swain's blog post Top Worst Crawl Space Insulation Ideas
"6) Radiant barrier- under the gravel is just a barrier but with holes each square inch its not a…"
15 hours ago
tedkidd replied to Luis Hernandez's discussion Distribution Efficiency and heating safety factor in TREAT in the group TREAT Software
"It is very common to find equipment grossly oversized. I mean 1.5 - 2x Manual J and 2-3x the size…"
15 hours ago
tedkidd replied to Luis Hernandez's discussion Basic Heat loss information in the group TREAT Software
"Luis,  Click "selected reports, energy savings and use, design heating and cooling…"
15 hours ago