The end of profits for Auditors/raters
100 Replies

90% of all my new energy audit customers now expect reduced or 'free' service. BPI has sites listing participating contractors who offer free audits. BPI has advertised rates of $250 for a whole…Continue

Started this discussion. Last reply by Ed Minch Feb 5, 2012.

Should BPI Auditors be Infrared Camera certified?
4 Replies

RESNET has set up standards for Infrared Camera certifications for their Raters. The standards are going to go into effect after the 2011 RESNET conference in Orlando in February. Specifice training…Continue

Started this discussion. Last reply by Paul Lasicki Jan 21, 2011.

RESNET/BPI IR Training
7 Replies

Does any one know if BPI is going to require any specific IR training or use?I understand that RESNET is working on their own Infrared qualifications for raters.Any one who has ever used IR along…Continue

Started this discussion. Last reply by Michael Stuart Nov 21, 2010.

 

allen p tanner's Page

Profile Information

Company
nyinfraredscan.com
Professional Certification
BPI certified auditor, level 3 IR, NY licensed Home Inspector,
Professional Interests
home construction
home inspections
thermal imaging
Energy auditing
Website URL
http://nyinfraredscan.com nyenergyauditors.com

Comment Wall (4 comments)

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

At 9:17am on July 2, 2011, Cindy Matthews said…
Thanks for the tips. I don't own any tools of the trade, have no money or credit to purchase any at this time and no family in this area. How would you connect with a business who already has the tools and needs people to use it for them?
At 6:35am on July 1, 2011, Cindy Matthews said…
Thanks for befriending me. You look like you're a wealth of information! :)
At 8:34am on November 21, 2010, TJ Ewing said…
PS RE: fan - yes the customer have their fans on 'run' continuously. No blower control thermostats as far as I know. This was a conscious choice to have the blower fan running all the time, when the furnace is on and off. I agree with you that it would cost more and create more wear...
At 8:31am on November 21, 2010, TJ Ewing said…
Hi Allen,
we took the bulletin board off (which showed evidence of wetting/rot on its backside) and the church reps were more than eager to do a destructive core given the many decades of trouble with this wall. So they did! We learned we have 4" block with at most a 1/2" air gap to the brick that is most likely impeded in many places by mortar. No vapor or air barrier present. There's been a lot of confusion by the church reps on when the wetness appears, which has made our theories more numerous. But at this point we have a concentrated drainage area of a large portion of roof, potential irrigation spray onto the brick, less than adequate drainage away from the brick wall, a weak drainage plane, no weeps in the wall, and some contact between the brick and concrete. Controlling water sources is primary in our minds as we think the wall is wicking bulk moisture via the wall surface and from the ground. When the morning sun hits the SE facing wall, it drives the moisture in which condenses underneath the interior wall paint. The church is replacing the bulletin board with standoffs and we are leaving our core hole open for now. So, we aim to control moisture first, and when the event happens again, take more details of the internal and external conditions when it does.

BTW when you talk about IR scanning masonry and needing to thermally load the wall, am I right you are saying to actively warm the wall? Or would the sun work if given the right conditions? I understand we want 18 degree differential ideally for all building envelope scanning, but with masonry has your experience shown you can get good thermograms with 18 degrees, or do you need active thermo loading. And if so, how do you typically load the wall?
Thanks!
TJ
 
 
 

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.

Latest Activity

Hal Skinner replied to Hal Skinner's discussion What this RCC will do on an exterior wall compared to standard paint. in the group The RCC Classroom (Radiant Control Coatings)
"You might want to check out this discussion in my…"
1 hour ago
Craig Bird replied to Hal Skinner's discussion What this RCC will do on an exterior wall compared to standard paint. in the group The RCC Classroom (Radiant Control Coatings)
"In this scenario the walls were made of R35 rigid foam. Even if ex-employee of big energy company…"
2 hours ago
Profile IconMary Patterson and Lisa Meaders joined Home Energy Pros
3 hours ago
Sean Lintow Sr replied to Kevin Jordan's discussion air infiltration total
"Sorry I don't have anything handy but pull a search for EqLA equivalent leakage…"
yesterday
Erik Henson commented on Andrew Navolio's blog post MEEA assists with Home Energy Certification programs
"It seems to me like we are trying to re-invent the wheel.  There are several available…"
Saturday
Egr renovations posted a status
Saturday
Craig Bird replied to Hal Skinner's discussion What this RCC will do on an exterior wall compared to standard paint. in the group The RCC Classroom (Radiant Control Coatings)
"Actually emissivity rating doesn't make much of a difference between coatings because almost…"