90% of all my new energy audit customers now expect reduced or 'free' service. BPI has sites listing participating contractors who offer free audits. BPI has advertised rates of $250 for a whole…Continue
Started this discussion. Last reply by Ed Minch Feb 5, 2012.
RESNET has set up standards for Infrared Camera certifications for their Raters. The standards are going to go into effect after the 2011 RESNET conference in Orlando in February. Specifice training…Continue
Started this discussion. Last reply by Paul Lasicki Jan 21, 2011.
Does any one know if BPI is going to require any specific IR training or use?I understand that RESNET is working on their own Infrared qualifications for raters.Any one who has ever used IR along…Continue
Started this discussion. Last reply by Michael Stuart Nov 21, 2010.
Judi Lyall joined allen p tanner's group
Steve White joined allen p tanner's group
Joe Urycki joined allen p tanner's group
Robert vanCreveld joined allen p tanner's group
Ron Stolicki joined allen p tanner's group
George Chura joined allen p tanner's group
David Starrett joined allen p tanner's group
Sharon Block joined allen p tanner's group
John Darlington joined allen p tanner's groupHome Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy, under the American Recovery and Reinvestment Act) and brought to you in partnership with Home Energy magazine.
Patrick Michaelyan replied to Patrick Michaelyan's discussion Hot Upper Stories
Ed Minch replied to Patrick Michaelyan's discussion Hot Upper Stories
Craig Savage commented on Craig Savage's video
Tom Delconte commented on Craig Savage's video
Ben Jacobs replied to Jose Macho's discussion Why Are Energy-Saving Home Inprovements Down??
Craig Savage commented on Craig Savage's video
Tom Delconte commented on Craig Savage's video
Cory Chovanec replied to Bachi Brunato's discussion Boxing and Insulating Around Non-ICAT Cans
Jon Haehnel replied to Jose Macho's discussion Why Are Energy-Saving Home Inprovements Down??
Tom Smith replied to Patrick Michaelyan's discussion Hot Upper Stories
John Rising replied to Bachi Brunato's discussion Boxing and Insulating Around Non-ICAT Cans
Isaac Savage's event was featured© 2013 Created by Lawrence Berkeley National Laboratory.
Comment Wall (4 comments)
You need to be a member of Home Energy Pros to add comments!
Join Home Energy Pros
we took the bulletin board off (which showed evidence of wetting/rot on its backside) and the church reps were more than eager to do a destructive core given the many decades of trouble with this wall. So they did! We learned we have 4" block with at most a 1/2" air gap to the brick that is most likely impeded in many places by mortar. No vapor or air barrier present. There's been a lot of confusion by the church reps on when the wetness appears, which has made our theories more numerous. But at this point we have a concentrated drainage area of a large portion of roof, potential irrigation spray onto the brick, less than adequate drainage away from the brick wall, a weak drainage plane, no weeps in the wall, and some contact between the brick and concrete. Controlling water sources is primary in our minds as we think the wall is wicking bulk moisture via the wall surface and from the ground. When the morning sun hits the SE facing wall, it drives the moisture in which condenses underneath the interior wall paint. The church is replacing the bulletin board with standoffs and we are leaving our core hole open for now. So, we aim to control moisture first, and when the event happens again, take more details of the internal and external conditions when it does.
BTW when you talk about IR scanning masonry and needing to thermally load the wall, am I right you are saying to actively warm the wall? Or would the sun work if given the right conditions? I understand we want 18 degree differential ideally for all building envelope scanning, but with masonry has your experience shown you can get good thermograms with 18 degrees, or do you need active thermo loading. And if so, how do you typically load the wall?
Thanks!
TJ