Walter Stachowicz
  • Inverness, FL
  • United States
Share on Facebook Share on Facebook Share
  • Featured Blogs
  • Discussions (3)
  • Events
  • Groups
  • Photos
  • Photo Albums
  • Videos
 

Walter Stachowicz's Page

Latest Activity

Walter Stachowicz commented on Glen Gallo's blog post Mechanical Ventilation
"Thanks for the comment, Curt.  I agree wholeheartedly, but the folks at Energy Star don't.  I recently did a 5 bedroom home with one occupant.  NO credit can be given for phantoms, nor natural ventilation, so the bath exhaust fan…"
Sep 9, 2012
Walter Stachowicz commented on Glen Gallo's blog post Mechanical Ventilation
"Does anyone have any suggestions for hot, humid areas? The exhaust only ventilation is going to bring in humid air through myriad little leaks.  With an RH of 73 in the summer, this can (and does) cause condensation on grilles and…"
Sep 7, 2012
Walter Stachowicz replied to John Webb's discussion DOE Home Energy SCORE
"I'm also interested in what's happening.  Had several inquiries about this in a local Green Building Committee today."
Oct 27, 2011
Walter Stachowicz just added their location.

(via No Title)

Sep 29, 2011
Walter Stachowicz replied to Karin Haerter's discussion A Boost for Energy Auditing from Consumer Reports
"I agree that this was a great article, up to the point where they recommended additional insulation, duct sealing and ceiling leak mitigation in the wrong order.  The duct guys and the people who seal the leaks in the ceiling are going to mess…"
Sep 22, 2011
Walter Stachowicz replied to Allison A. Bailes III's discussion RESNET and Home Depot - Anyone worried about that alliance?
"Jamie, I understand from the RESNET site that raters do not have to take a test, but they must associate themselves with one of the four HESP providers for certification. (via Steve Baden) This will cost about $300 plus proof of insurance. RESNET…"
Nov 21, 2010
Walter Stachowicz is now a member of Home Energy Pros
Nov 21, 2010

Profile Information

Company
Conservation Plus
Professional Certification
RESNET Rater

Comment Wall

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

  • No comments yet!
 
 
 

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.  Home Energy Pros is sponsored by the Better Buildings Residential Network.

Latest Activity

Hannah Finch posted a blog post

Want to Lead a Breakout Session at RaterFest! 2015?

We are adding something new to RaterFest! this year... attendee led breakout sessions on Saturday…See More
4 hours ago
Rod Fox replied to Rod Fox's discussion Does calcification affect electric water heater aquastat temperature sensor performance?
"We're in climate zone 5 (near Santa Fe, NM) where it's dry as a bone. Gonna head to that…"
5 hours ago
Bud Poll replied to Rod Fox's discussion Does calcification affect electric water heater aquastat temperature sensor performance?
"The two 4500 watt elements will never operate simultaneously.  It will be one or the…"
5 hours ago
Rod Fox replied to Rod Fox's discussion Does calcification affect electric water heater aquastat temperature sensor performance?
"Correction to this last posting... This model only operates one element at a time, not two in…"
5 hours ago
Rod Fox replied to Rod Fox's discussion Does calcification affect electric water heater aquastat temperature sensor performance?
"Agreed. Incidentally, I just called tech support at Bradford White (and actually spoke to a…"
5 hours ago
Hans Joachim Preiss replied to Rod Fox's discussion Does calcification affect electric water heater aquastat temperature sensor performance?
"Rod, Because the tank is not overheating, the behavior is either normal for this tank or there is a…"
6 hours ago
Rod Fox replied to Rod Fox's discussion Does calcification affect electric water heater aquastat temperature sensor performance?
"Hey thanks Hans. I didn't know about the benefit of the heatpump units having the elements…"
6 hours ago
Rod Fox replied to Rod Fox's discussion Does calcification affect electric water heater aquastat temperature sensor performance?
"I'm not sure if the tank was flushed at the time of element replacement. I would have hoped…"
6 hours ago

© 2015   Created by Lawrence Berkeley National Laboratory.

Badges  |  Report an Issue  |  Terms of Service