Blower Door Testing

Started this discussion. Last reply by Curt Kinder Apr 11, 2013. 5 Replies

I've been asked to perform blower door testing on a house that is to be built.The architects builders estimate specifications state " Perform a blower door test on the house after the wall sheathing,…Continue

 

Thomas Varney's Page

Latest Activity

Thomas Varney replied to Matthew Damon's discussion Upgrading a vented tongue and groove cathedral ceiling in the group Best Practices (Residential)
" Hi Matt, The code in Maine does require a minimum of R20 impermeable insulation but it is important to note that this is based on a total insulation value of R49. If you can't get a total of R49 into the rafter space this R20 value…"
Jul 18, 2014
Thomas Varney joined Sean Lintow Sr's group
Thumbnail

Best Practices (Residential)

Best Building, Retrofitting, or even Auditing Practices - what are they, what should change, what needs to find it's way to the dust bin of history?See More
Jul 18, 2014
Thomas Varney replied to Steve Burke's discussion Urea Formaldehyde Foam Insulation (UFFI)
"I am amazed that no one understands that the space behind a masonry wall is there to allow moisture the works its way through the bricks/blocks to weep down and out through the installed weep holes at the top of the foundation wall. Filling this…"
Feb 13, 2014
Diane Chojnowski left a comment for Thomas Varney
"Welcome to Home Energy Pros! Feel free to join the conversation in the Forum and Groups. And share your energy efficiency photos, videos and upcoming events. If you're blogging about home performance, this is the place for you! Don't…"
Jun 10, 2013
Curt Kinder replied to Thomas Varney's discussion Blower Door Testing
"I do it routinely for sprayfoam projects 1ACH50 ain't your problem...you are just a scorekeeper. If the subs whose trades involve air sealing haven't built to that level of tightness, they are in for a painful process. Obviously you…"
Apr 11, 2013
David Meiland replied to Thomas Varney's discussion Blower Door Testing
"Well, it has everything to do with how much time and money you're given to set up and perform the test. If they want the ceiling completely masked off, or the roof venting sealed completely on a temporary basis... go for it... and bill them for…"
Apr 10, 2013
Thomas Varney replied to Thomas Varney's discussion Blower Door Testing
"Thanks for the input. I've been searching the internet for the last few days and I found a local company's website called G*O Logic. They have been building homes using the Passivhaus as a reference. One video showed a blower door test…"
Apr 10, 2013
Thomas Varney's discussion was featured

Blower Door Testing

I've been asked to perform blower door testing on a house that is to be built.The architects builders estimate specifications state " Perform a blower door test on the house after the wall sheathing, rigid foam wall sheathing, roof sheathing, and windows are installed and sealed, prior to installing interior and wall insulation. Maximum 1.00 air changes per hour at 50 pascals. Perform another blower door test after insulation is installed." I foresee at least one big problem in that there will…See More
Apr 10, 2013
Sean Lintow Sr replied to Thomas Varney's discussion Blower Door Testing
"All things are possible though that will be a very tough number to hit as David mentioned. Beyond that give them your rate per test & additional hourly for directed air sealing Doing this test is the same as a regular one with the…"
Apr 8, 2013
David Meiland replied to Thomas Varney's discussion Blower Door Testing
"Definitely a problem. If the house has a flat ceiling, then the best thing is for the drywallers to hang and tape the ceiling out of sequence, so that you're testing the ceiling, the wall sheathing w/ windows and doors, and the floor.…"
Apr 8, 2013
Thomas Varney posted a discussion

Blower Door Testing

I've been asked to perform blower door testing on a house that is to be built.The architects builders estimate specifications state " Perform a blower door test on the house after the wall sheathing, rigid foam wall sheathing, roof sheathing, and windows are installed and sealed, prior to installing interior and wall insulation. Maximum 1.00 air changes per hour at 50 pascals. Perform another blower door test after insulation is installed." I foresee at least one big problem in that there will…See More
Apr 8, 2013

Thomas Varney just added their location.
(via Member Map)

Mar 30, 2013
Thomas Varney is now a member of Home Energy Pros
Mar 28, 2013

Profile Information

Company
Atlantic Home Performance
Professional Certification
BPI Building Analyst, Envelope Specialist
Professional Interests
MUBEC TPI
Website URL
http://AtlanticHomePerformanceLLC.com

Comment Wall (1 comment)

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

At 6:28am on June 10, 2013, Diane Chojnowski said…

Welcome to Home Energy Pros! Feel free to join the conversation in the Forum and Groups. And share your energy efficiency photos, videos and upcoming events. If you're blogging about home performance, this is the place for you!

Don't forget to upload your profile photo. And add your location on our Member Map!


Thanks!
Diane, HEP Moderator

 
 
 

Featured Forum Discussions

Too many BTU's. Too much horsepower?

Started by Steve in General Forum. Last reply by Eric Kjelshus 21 hours ago. 4 Replies

Stack/wind pressure and flow networks.

Started by Daniel James Grundy in Training. Last reply by Daniel James Grundy on Thursday. 5 Replies

BDT with vermiculite in hollow CMU walls?

Started by Brad Cook in General Forum. Last reply by John Nicholas on Thursday. 2 Replies

Strange IR Image

Started by Larry Nissman in General Forum. Last reply by Brad Cook Mar 9. 7 Replies

Videos

  • Add Videos
  • View All

Latest Activity

Eric Kjelshus replied to Steve's discussion Too many BTU's. Too much horsepower?
"Its more about run time with high RH removing, than to large over sized AC unit, in houses.  …"
21 hours ago
Sarah OConnell posted a blog post

Crowdsourcing for Innovation

Share Your Ideas!Novel Building Envelope Design for Increased Thermal PerformanceIn 2014, more than…See More
yesterday
Colin de Paor is now a member of Home Energy Pros
yesterday
Walter Ahlgrim replied to Steve's discussion Too many BTU's. Too much horsepower?
"The 5 ton system you have is not 500 hp racecar engines they are 500 hp truck engines. The duct…"
yesterday
Daniel James Grundy replied to Daniel James Grundy's discussion Stack/wind pressure and flow networks.
"So I wanted to start with a basic who can help then go into more detail later. But yes find…"
Thursday
Daniel James Grundy replied to Daniel James Grundy's discussion Stack/wind pressure and flow networks.
"My tutor got back to me and while areas don't quite feel right a little to much assumptions…"
Thursday
Brennan Less replied to Daniel James Grundy's discussion Stack/wind pressure and flow networks.
"Daniel, I'm assuming you're trying to predict the airflows through the different openings…"
Thursday
Martin Newmark joined allen p tanner's group
Thumbnail

Energy Auditing Equipment for Sale, Trade or to Purchase

Discuss the pros and cons of the equipment you are interested in prior to purchase. Post equipment…See More
Thursday

Home Energy Pros

Welcome to Home Energy Pros – the unique digital community by and for those who work in the home energy performance arena.

Home Energy Pros was founded by the developers of Home Energy Saver Pro (supported by the U.S. Department of Energy) and brought to you in partnership with Home Energy magazine.  Home Energy Pros is sponsored by the Better Buildings Residential Network. Please honor our Guidelines

© 2017   Created by Lawrence Berkeley National Laboratory.   Powered by

Badges  |  Report an Issue  |  Terms of Service