Sloan Ritchie
  • Seattle, WA
  • United States
Share on Facebook Share on Facebook Share Twitter

Sloan Ritchie's Groups

Sloan Ritchie's Discussions

Interior rigid insulation retrofit
6 Replies

On this retrofit project, the home has vaulted ceilings, so plenty of room to add insulation at the interior ceiling and re-finish.  There's existing 7.5" (poorly) insulated ceiling joist bays with…Continue

Started this discussion. Last reply by Bradford E. White Jan 5, 2011.

Looking for a good detail for using 1" rigid on exterior
7 Replies

Anyone used 1" rigid in a new exterior wall assembly before?  What are the pros & cons, which rigid product did you use, which weather membrane (some are integral to the foam too).  Any…Continue

Started this discussion. Last reply by Al Heath Jan 5, 2011.

 

Sloan Ritchie's Page

Latest Activity

Al Heath replied to Sloan Ritchie's discussion Looking for a good detail for using 1" rigid on exterior
"I just finished a deep retrofit and used 2" polyisocyurate interiorly firectly over old rock, strapping, new rock.   This site has the best free articles…"
Jan 5, 2011
Bradford E. White replied to Sloan Ritchie's discussion Interior rigid insulation retrofit
"I probably should have been more clear, but yes, the new applied interior skin would have an appropriate class of vapor retarder. That said, if the edges are not sealed, even the insulation will not matter. Heat and moisture will go where it is not."
Jan 5, 2011
Ed Voytovich replied to Sloan Ritchie's discussion Interior rigid insulation retrofit
"Nice project, Leo.  If your Dow rep is as stellar as mine is, she can probably help you out in future with a piece of software they have that models your wall assembly and calculates where the dew point will fall at a given temperature."
Jan 5, 2011
Leo Klisch replied to Sloan Ritchie's discussion Looking for a good detail for using 1" rigid on exterior
"Yes, the dew point is the issue but also has to do with cold air leakage through cracks around the foam panel joints and windows that ends up creating cold spots inside the wall for potential small spots of condensation inside the wall if inside…"
Jan 5, 2011
Leo Klisch replied to Sloan Ritchie's discussion Interior rigid insulation retrofit
"In 2006 I general contracted a house that we now live in. I was going to foam on top of the 5/8 sheet rock (needed for fire code) that was installed on the vaulted and drop ceilings. Because of cost and schedule I decided to instead use 2"…"
Jan 5, 2011
Sloan Ritchie replied to Sloan Ritchie's discussion Looking for a good detail for using 1" rigid on exterior
"I discovered this comprehensive answer to the design question here: http://www.greenbuildingadvisor.com/blogs/dept/musings/calculating-minimum-thickness-rigid-foam-sheathing thanks for all your suggestions!"
Jan 5, 2011
Ed Voytovich replied to Sloan Ritchie's discussion Looking for a good detail for using 1" rigid on exterior
"In Central NY we use 2" of XPS to keep the dew point at heating design temperature (-2°F) outside the wall assembly.  These homes are quite comfortable, get excellent blower numbers, and are well prepared to fend off the universal…"
Jan 5, 2011
Sean Lintow Sr replied to Sloan Ritchie's discussion Interior rigid insulation retrofit
"I would lean more towards Ed's last solution with a caveat, I am assuming this roof is vented - if so I would trim down some XPS panels as firring strips 1.5" x 1.5" placed against the roof sheathing against the joist (2 in each bay -…"
Jan 5, 2011
Jim Peck replied to Sloan Ritchie's discussion Looking for a good detail for using 1" rigid on exterior
"Interesting Conclusions in the "White Paper"."
Jan 5, 2011
Ed Voytovich replied to Sloan Ritchie's discussion Interior rigid insulation retrofit
"If the insulation is on the inside in a heating climate it needs to be an effective boundary against vapor transmission to keep moisture away from a potential condensing surface.  Especially if there is a tongue and groove ceiling finish. …"
Jan 5, 2011
Bradford E. White replied to Sloan Ritchie's discussion Interior rigid insulation retrofit
"I have done both interior applied and exterior applied. Both of us will agree that exterior is superior, with inherently higher integrity. But reality dictates, so will not argue that point. When you say EPS, I presume you mean expanded polystyrene,…"
Jan 5, 2011
Sloan Ritchie joined Sean Lintow Sr's group
Thumbnail

Best Practices (Residential)

Best Building, Retrofitting, or even Auditing Practices - what are they, what should change, what needs to find it's way to the dust bin of history?See More
Jan 4, 2011
Sloan Ritchie posted a discussion

Interior rigid insulation retrofit

On this retrofit project, the home has vaulted ceilings, so plenty of room to add insulation at the interior ceiling and re-finish.  There's existing 7.5" (poorly) insulated ceiling joist bays with 1/2" drywall finish, so one option is to simply add say 4" of EPS to the assembly, screw & glue to the drywall, and then finish that with perhaps cedar panels. Question is, is this a durable assembly, one that won't have moisture or other problems?  Ideally we'd add it on top of the roof…See More
Jan 4, 2011
William Wesson replied to Sloan Ritchie's discussion Looking for a good detail for using 1" rigid on exterior
"Possibly overkill, but the Building Science Corp white paper might help:   http://www.buildingscience.com/documents/reports/rr-1012-residential-exterior-wall-superinsulation-retrofit/view"
Jan 4, 2011
Scott cragun replied to Sloan Ritchie's discussion Looking for a good detail for using 1" rigid on exterior
"I've used XPS rigid foam on both new construction and retro-fit applications, the amount of rigid foam ( R value) will depend on the climate zone you live in, colder climate zones require a higher percentage of the balance between exterior…"
Nov 25, 2010
Sloan Ritchie posted a discussion

Looking for a good detail for using 1" rigid on exterior

Anyone used 1" rigid in a new exterior wall assembly before?  What are the pros & cons, which rigid product did you use, which weather membrane (some are integral to the foam too).  Any experiences good or bad are welcome.ThanksSee More
Nov 24, 2010

Profile Information

Company
Cascade Built
Professional Certification
LEED AP Homes, BD&C
Professional Interests
Sustainable building, energy efficiency
Website URL
http://www.cascadebuilt.com
Facebook Page
http://www.facebook.com/pages/Cascade-Built-Backyard-Box/340754281512

Comment Wall

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

  • No comments yet!
 
 
 

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.

Latest Activity

Kim Tanner updated an event

Beyond Residential Testing at The Energy Conservatory

May 14, 2014 to May 16, 2014
The Energy Conservatory (TEC) is hosting a Beyond Residential Testing event. In addition we are…See More
25 minutes ago
Casey Gesell posted a video

Super Attic - Attic Insulation System

http://www.drenergysaver.com | 1-888-225-6260 The new Super Attic: Advanced Conversion System -- converts your attic from a vented attic into an unvented at...
48 minutes ago

Casey Gesell just added their location.
(via Member Map)

2 hours ago
H.O. Electric posted a video

H.O. Services, Generator, Electrical, Plumbing, Heating, Cooling, Belmont, Lexington, Arlington, MA

H.O. Services is your residential Electric-Plumbing-Heating-Cooling Specialist. We are an electrical contracting company providing homeowners the best Electr...
3 hours ago
Jim Gunshinan's blog post was featured
3 hours ago
Profile IconMichael and michael coleman joined Home Energy Pros
3 hours ago
Luis Hernandez posted a discussion

Air Source Heat pump or mini-split efficiency

Greetings everyone!    I have a technical questions I hope I could get some feedback! I understood…See More
4 hours ago
Jim Gunshinan posted blog posts
22 hours ago
H.O. Electric posted a photo

about us-team

H.O. Services is your residential Electric-Plumbing-Heating-Cooling Specialist. We are an…
22 hours ago
H.O. Electric added a discussion to the group News & Announcements
Thumbnail

Stay Cool With Easy To Install Ductless AC System!

Stay Cool With Easy To Install Ductless AC System!   Save $300.00 Off A New AC System For A Limited…See More
22 hours ago
Richard Wells commented on Diane Chojnowski's group Facebook Pages
"Three thousand home energy efficiency audits, and nearly a thousand retrofits in four short…"
yesterday
Richard Wells joined Diane Chojnowski's group
Thumbnail

Facebook Pages

Does your company or organization have a Facebook Page?This group is for pros who have facebook…See More
yesterday

© 2014   Created by Lawrence Berkeley National Laboratory.

Badges  |  Report an Issue  |  Terms of Service