Interior rigid insulation retrofit

Started this discussion. Last reply by Bradford E. White Jan 5, 2011. 6 Replies

On this retrofit project, the home has vaulted ceilings, so plenty of room to add insulation at the interior ceiling and re-finish.  There's existing 7.5" (poorly) insulated ceiling joist bays with…Continue

Looking for a good detail for using 1" rigid on exterior

Started this discussion. Last reply by Al Heath Jan 5, 2011. 7 Replies

Anyone used 1" rigid in a new exterior wall assembly before?  What are the pros & cons, which rigid product did you use, which weather membrane (some are integral to the foam too).  Any…Continue

 

Sloan Ritchie's Page

Latest Activity

Al Heath replied to Sloan Ritchie's discussion Looking for a good detail for using 1" rigid on exterior
"I just finished a deep retrofit and used 2" polyisocyurate interiorly firectly over old rock, strapping, new rock.   This site has the best free articles…"
Jan 5, 2011
Bradford E. White replied to Sloan Ritchie's discussion Interior rigid insulation retrofit
"I probably should have been more clear, but yes, the new applied interior skin would have an appropriate class of vapor retarder. That said, if the edges are not sealed, even the insulation will not matter. Heat and moisture will go where it is not."
Jan 5, 2011
Ed Voytovich replied to Sloan Ritchie's discussion Interior rigid insulation retrofit
"Nice project, Leo.  If your Dow rep is as stellar as mine is, she can probably help you out in future with a piece of software they have that models your wall assembly and calculates where the dew point will fall at a given temperature."
Jan 5, 2011
Leo Klisch replied to Sloan Ritchie's discussion Looking for a good detail for using 1" rigid on exterior
"Yes, the dew point is the issue but also has to do with cold air leakage through cracks around the foam panel joints and windows that ends up creating cold spots inside the wall for potential small spots of condensation inside the wall if inside…"
Jan 5, 2011
Leo Klisch replied to Sloan Ritchie's discussion Interior rigid insulation retrofit
"In 2006 I general contracted a house that we now live in. I was going to foam on top of the 5/8 sheet rock (needed for fire code) that was installed on the vaulted and drop ceilings. Because of cost and schedule I decided to instead use 2"…"
Jan 5, 2011
Sloan Ritchie replied to Sloan Ritchie's discussion Looking for a good detail for using 1" rigid on exterior
"I discovered this comprehensive answer to the design question here: http://www.greenbuildingadvisor.com/blogs/dept/musings/calculating-minimum-thickness-rigid-foam-sheathing thanks for all your suggestions!"
Jan 5, 2011
Ed Voytovich replied to Sloan Ritchie's discussion Looking for a good detail for using 1" rigid on exterior
"In Central NY we use 2" of XPS to keep the dew point at heating design temperature (-2°F) outside the wall assembly.  These homes are quite comfortable, get excellent blower numbers, and are well prepared to fend off the universal…"
Jan 5, 2011
Sean Lintow Sr replied to Sloan Ritchie's discussion Interior rigid insulation retrofit
"I would lean more towards Ed's last solution with a caveat, I am assuming this roof is vented - if so I would trim down some XPS panels as firring strips 1.5" x 1.5" placed against the roof sheathing against the joist (2 in each bay -…"
Jan 5, 2011
Jim Peck replied to Sloan Ritchie's discussion Looking for a good detail for using 1" rigid on exterior
"Interesting Conclusions in the "White Paper"."
Jan 5, 2011
Ed Voytovich replied to Sloan Ritchie's discussion Interior rigid insulation retrofit
"If the insulation is on the inside in a heating climate it needs to be an effective boundary against vapor transmission to keep moisture away from a potential condensing surface.  Especially if there is a tongue and groove ceiling finish. …"
Jan 5, 2011
Bradford E. White replied to Sloan Ritchie's discussion Interior rigid insulation retrofit
"I have done both interior applied and exterior applied. Both of us will agree that exterior is superior, with inherently higher integrity. But reality dictates, so will not argue that point. When you say EPS, I presume you mean expanded polystyrene,…"
Jan 5, 2011
Sloan Ritchie joined Sean Lintow Sr's group
Thumbnail

Best Practices (Residential)

Best Building, Retrofitting, or even Auditing Practices - what are they, what should change, what needs to find it's way to the dust bin of history?See More
Jan 4, 2011
Sloan Ritchie posted a discussion

Interior rigid insulation retrofit

On this retrofit project, the home has vaulted ceilings, so plenty of room to add insulation at the interior ceiling and re-finish.  There's existing 7.5" (poorly) insulated ceiling joist bays with 1/2" drywall finish, so one option is to simply add say 4" of EPS to the assembly, screw & glue to the drywall, and then finish that with perhaps cedar panels. Question is, is this a durable assembly, one that won't have moisture or other problems?  Ideally we'd add it on top of the roof…See More
Jan 4, 2011
William Wesson replied to Sloan Ritchie's discussion Looking for a good detail for using 1" rigid on exterior
"Possibly overkill, but the Building Science Corp white paper might help:   http://www.buildingscience.com/documents/reports/rr-1012-residential-exterior-wall-superinsulation-retrofit/view"
Jan 4, 2011
Scott cragun replied to Sloan Ritchie's discussion Looking for a good detail for using 1" rigid on exterior
"I've used XPS rigid foam on both new construction and retro-fit applications, the amount of rigid foam ( R value) will depend on the climate zone you live in, colder climate zones require a higher percentage of the balance between exterior…"
Nov 25, 2010
Sloan Ritchie posted a discussion

Looking for a good detail for using 1" rigid on exterior

Anyone used 1" rigid in a new exterior wall assembly before?  What are the pros & cons, which rigid product did you use, which weather membrane (some are integral to the foam too).  Any experiences good or bad are welcome.ThanksSee More
Nov 24, 2010

Profile Information

Company
Cascade Built
Professional Certification
LEED AP Homes, BD&C
Professional Interests
Sustainable building, energy efficiency
Website URL
http://www.cascadebuilt.com
Facebook Page
http://www.facebook.com/pages/Cascade-Built-Backyard-Box/340754281512

Comment Wall

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

  • No comments yet!
 
 
 

Featured Forum Discussions

Too many BTU's. Too much horsepower?

Started by Steve in General Forum. Last reply by Eric Kjelshus on Saturday. 4 Replies

Stack/wind pressure and flow networks.

Started by Daniel James Grundy in Training. Last reply by Daniel James Grundy on Thursday. 5 Replies

BDT with vermiculite in hollow CMU walls?

Started by Brad Cook in General Forum. Last reply by John Nicholas on Thursday. 2 Replies

Strange IR Image

Started by Larry Nissman in General Forum. Last reply by Brad Cook Mar 9. 7 Replies

Videos

  • Add Videos
  • View All

Latest Activity

Diane Chojnowski replied to Quinn Korzeniecki's discussion Don MacOdrum Receives BPI's 2017 Tony Woods Award and Four Others Inducted in to Hall of Fame in the group Building Performance Institute (BPI)
"Congratulations Mike! Thanks for all you do for the home performance industry!"
26 minutes ago
Sarah OConnell's blog post was featured
30 minutes ago
Mike Rogers replied to Quinn Korzeniecki's discussion Don MacOdrum Receives BPI's 2017 Tony Woods Award and Four Others Inducted in to Hall of Fame in the group Building Performance Institute (BPI)
"Congratulations to Don! A deep thanks for the honor--and even more thanks to the many who've…"
12 hours ago
Mike Rogers joined Building Performance Institute's group
Thumbnail

Building Performance Institute (BPI)

BPI is the nation's premier standards development, quality assurance and credentialing organization…See More
12 hours ago
Horace Douglas Hunt, Jr. replied to eric anderson's discussion Energy auditing equipment for sale in the group Energy Auditing Equipment for Sale, Trade or to Purchase
"Have you sold this or still interested in sales of this equipment?"
15 hours ago
Charles Maier is now a member of Home Energy Pros
yesterday
Derrick Brodanex joined allen p tanner's group
Thumbnail

Energy Auditing Equipment for Sale, Trade or to Purchase

Discuss the pros and cons of the equipment you are interested in prior to purchase. Post equipment…See More
yesterday
Eric Kjelshus replied to Steve's discussion Too many BTU's. Too much horsepower?
"Its more about run time with high RH removing, than to large over sized AC unit, in houses.  …"
Saturday

Home Energy Pros

Welcome to Home Energy Pros – the unique digital community by and for those who work in the home energy performance arena.

Home Energy Pros was founded by the developers of Home Energy Saver Pro (supported by the U.S. Department of Energy) and brought to you in partnership with Home Energy magazine.  Home Energy Pros is sponsored by the Better Buildings Residential Network. Please honor our Guidelines

© 2017   Created by Lawrence Berkeley National Laboratory.   Powered by

Badges  |  Report an Issue  |  Terms of Service