Scott cragun
  • Ketchikan, AK
  • United States
Share on Facebook Share on Facebook Share

Scott cragun's Groups

 

Scott cragun's Page

Latest Activity

Scott cragun just added their location.
Nov 25, 2010
Scott cragun replied to Al Maloney's discussion What is the R Value of a 2x6 dense packed cellulose wall?
"According to National Fiber's website a 2 x 6 wall at 5.5 " thick has an R value of R20 when dense packed at 3.5 lbs per cubic foot. The reason the Code has a minimum wall insulation requirement of R20 is because thats as good as it gets…"
Nov 25, 2010
Scott cragun replied to Sloan Ritchie's discussion Looking for a good detail for using 1" rigid on exterior
"I've used XPS rigid foam on both new construction and retro-fit applications, the amount of rigid foam ( R value) will depend on the climate zone you live in, colder climate zones require a higher percentage of the balance between exterior…"
Nov 25, 2010
Scott cragun replied to Allison A. Bailes III's discussion RESNET and Home Depot - Anyone worried about that alliance?
"I guess my first question would be what type of alliance have they formed? is Home Depot going to offer Energy Ratings or Audits at a reduced price? or is the concern that the rater may steer their clients to Home Depot for home improvement…"
Nov 19, 2010
Scott cragun joined James Sayers's group
Thumbnail

Marketing Energy Efficiency

Sharing ideas, tools and examples of promoting energy efficiency to consumersSee More
Nov 9, 2010
Scott cragun joined Tom White's group
Thumbnail

Weatherization

Share your concerns and successes as a weatherization professional, or information for this community.
Nov 9, 2010
Scott cragun is now a member of Home Energy Pros
Nov 3, 2010

Profile Information

Company
HomeTech
Professional Certification
Energy rater, Home Inspector
Professional Interests
Energy efficient retrofits

Comment Wall

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

  • No comments yet!
 
 
 

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.  Home Energy Pros is sponsored by the Better Buildings Residential Network.

Latest Activity

Dale Pickard replied to Rod Fox's discussion Does altitude affect AFUE? or just the input/output BTUs?
"Hans, The car manufacturer's are doing it with mass flow sensors and oxygen sensors…"
7 hours ago
Dale Pickard replied to Rod Fox's discussion Does altitude affect AFUE? or just the input/output BTUs?
"I was trying to avoid naming manufacturers, but I was going by the published information for the…"
8 hours ago
Eric Kjelshus replied to Rod Fox's discussion Does altitude affect AFUE? or just the input/output BTUs?
"I look at this not about AFUE,  but flue gas dewpoint.  If your burn rate is rotting the…"
10 hours ago
Bob Blanchette replied to Kirsten Richnavsky's discussion Crawl spaces and attics: OSHA to implement new rule on confined spaces
"Keeping HVAC equipment out of attics should be part of the new code. "
11 hours ago
Linda Wigington replied to Linda Wigington's discussion Weigh in - Honorable Mention? 2nd Base? Half-Way There? 50% Better? On the Path? in the group 1000 Home Challenge
"Nickie -  Good points. I think it is easy enough to flag or designate projects that achieve…"
12 hours ago
Morgan M Audetat replied to Rod Fox's discussion Does altitude affect AFUE? or just the input/output BTUs?
"Though Viessmann is relatively unique in the application of Lambda technology to condensing…"
13 hours ago
Lars olsen posted a blog post
21 hours ago
Eric Kjelshus replied to Rod Fox's discussion Does altitude affect AFUE? or just the input/output BTUs?
"The heat exchanger gets burnt out, if presser is to high or if mix is to rich, then I see holes in…"
yesterday

© 2015   Created by Lawrence Berkeley National Laboratory.