Scott cragun
  • Ketchikan, AK
  • United States
Share on Facebook Share on Facebook Share

Scott cragun's Groups

 

Scott cragun's Page

Latest Activity

Scott cragun just added their location.
Nov 25, 2010
Scott cragun replied to Al Maloney's discussion What is the R Value of a 2x6 dense packed cellulose wall?
"According to National Fiber's website a 2 x 6 wall at 5.5 " thick has an R value of R20 when dense packed at 3.5 lbs per cubic foot. The reason the Code has a minimum wall insulation requirement of R20 is because thats as good as it gets…"
Nov 25, 2010
Scott cragun replied to Sloan Ritchie's discussion Looking for a good detail for using 1" rigid on exterior
"I've used XPS rigid foam on both new construction and retro-fit applications, the amount of rigid foam ( R value) will depend on the climate zone you live in, colder climate zones require a higher percentage of the balance between exterior…"
Nov 25, 2010
Scott cragun replied to Allison A. Bailes III's discussion RESNET and Home Depot - Anyone worried about that alliance?
"I guess my first question would be what type of alliance have they formed? is Home Depot going to offer Energy Ratings or Audits at a reduced price? or is the concern that the rater may steer their clients to Home Depot for home improvement…"
Nov 19, 2010
Scott cragun joined James Sayers's group
Thumbnail

Marketing Energy Efficiency

Sharing ideas, tools and examples of promoting energy efficiency to consumersSee More
Nov 9, 2010
Scott cragun joined Tom White's group
Thumbnail

Weatherization

Share your concerns and successes as a weatherization professional, or information for this community.
Nov 9, 2010
Scott cragun is now a member of Home Energy Pros
Nov 3, 2010

Profile Information

Company
HomeTech
Professional Certification
Energy rater, Home Inspector
Professional Interests
Energy efficient retrofits

Comment Wall

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

  • No comments yet!
 
 
 

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.

Latest Activity

randy tolowski replied to randy tolowski's discussion Another unvented roof question
"you are correct. we won't know how these new products perform long term. I hope I get the ok…"
1 hour ago
randy tolowski replied to randy tolowski's discussion Another unvented roof question
"good info Sean thanks for the heads-up on calling it a sip. code approved hot roof system sounds…"
1 hour ago
Bud Poll replied to randy tolowski's discussion Another unvented roof question
"I've removed caulking that was over 30 years old and it outlasted the materials to which it…"
17 hours ago
Profile IconAmanda Hallock, Kalvis, Tyler Grubbs and 6 more joined Home Energy Pros
19 hours ago
Corbett Lunsford posted videos
20 hours ago
Sean Lintow Sr replied to randy tolowski's discussion Another unvented roof question
21 hours ago
randy tolowski posted discussions
22 hours ago
Todd Collins replied to Tom Strumolo's discussion Ancient (70's) wall foam insulation, now a powder.
"What did you find about the dust?  "
yesterday

© 2015   Created by Lawrence Berkeley National Laboratory.

Badges  |  Report an Issue  |  Terms of Service