Ken wilson joined Diane Chojnowski's group
Thumbnail

Facebook Pages

Does your company or organization have a Facebook Page?This group is for pros who have facebook pages. Post the link to your facebook page in the comments so that folks can like you on facebook.See More
Dec 20, 2013
Ken wilson commented on Elizabeth Stuart's blog post CA Title 24 will require RTUs to have automated fault detection and diagnostics
"American standard/Trane rooftops have that in their units stock already. Good idea problem solved."
Oct 18, 2012
Ken wilson replied to Eric M. Fletcher's discussion Winter condensation on windows in a house that is very well insulated.
"I am referring to the terminology of the products used in the hvac trade by the vendors and tradespeople in the trade at least in the north central us climate. I am sure there are many products in the market that share the same common name. I own…"
Sep 28, 2012
Ken wilson replied to Eric M. Fletcher's discussion Winter condensation on windows in a house that is very well insulated.
"in general a home should ventilate approx, 8 air changes per day. As the home is tighter it will not have that amount naturally, so less than 8 air changes and any moisture produced through living in, cooking, bathing etc. is trapped inside and will…"
Sep 28, 2012
Ken wilson replied to James McGarvey's discussion Mini Split Heat Pumps
"Thanks I always use nitrogen on every job to ensure cleanliess even on a new lineset and also to use to pressure test to ensure your fitting s have no leaks. Then the microns gauge we use on every system to ensure a proper vaccum. If there ever is a…"
Sep 21, 2012
Ken wilson replied to James McGarvey's discussion Mini Split Heat Pumps
"I am a contractor and have installed these units. Some of them are capable of heating down to -13 deg. F. They are fairly complex and work well but must be installed properly with nitrogen gas and vaccum pumps and micron gauges. Awesome efficiency…"
Sep 20, 2012
Diane Chojnowski left a comment for Ken wilson
"Hi Ken, Welcome to Home Energy Pros. Feel free to join the conversation in the Forum and Groups. And share your energy efficiency photos, videos and upcoming events. If you're blogging about home performance, this is the place for…"
Aug 10, 2012
Ken wilson is now a member of Home Energy Pros
Aug 9, 2012

Profile Information

Company
Wilson hvac co.
Professional Certification
N/a
Professional Interests
Hvac contractor with blower door testing, flow hood,Manul J heat loss clalc software, experienced in design and install of geothermal, air source ducted heat pumps, ductless het pumps, boilers, photovoltaic solar, radiant heat, commercil and residential, low voltage controls experience nd power quality testing and retrofit knowledge.
Website URL
http://Www.wilsonhvac.com
Facebook Page
Wilsonhvac

Comment Wall (1 comment)

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

At 8:11am on August 10, 2012, Diane Chojnowski said…

Hi Ken,

Welcome to Home Energy Pros. Feel free to join the conversation in the Forum and Groups. And share your energy efficiency photos, videos and upcoming events. If you're blogging about home performance, this is the place for you!

Don't forget to upload your profile photo. And add your location on our Member Map.

Thanks!

Diane, HEP Moderator

 
 
 

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.

Latest Activity

Bud Poll replied to richard gaughan's discussion Advice for heating a 3-story Vermont home built in 1900?
"Hi Richard, Being a science writer and this being rental units, here is a moral dilemma you…"
1 hour ago
richard gaughan posted a discussion

Advice for heating a 3-story Vermont home built in 1900?

I'm a science writer, as opposed to an energy professional, and I joined this group to try to keep…See More
5 hours ago
Christopher Talarico posted a discussion

Heating with Tankless Water Heater & Hydronic Air Handler vs. Gas Furnace

Hi,I've looked around online and haven't found a lot of good information on home heating with…See More
15 hours ago
Profile IconSara Sabol, Christopher Talarico and Aaren Stewart joined Home Energy Pros
18 hours ago
Hal Skinner replied to Andy Gostisha's discussion Disguising Ductless Heat Pump Units
"Hi Andy. The bare metal units on a roof stick out like a sore thumb .  Coating them with our…"
18 hours ago
Paul Morin replied to Stephen Standley's discussion Which reading is more reliable on a Minneapolis Duct Blaster?
"Sorry for chiming in so late.  Sean’s comment early on in the discussion was the closest…"
21 hours ago
jerry gentile posted a status
"hello- anyone challenge the written QCI exam?"
yesterday
Kevin Jordan posted photos
yesterday

© 2014   Created by Lawrence Berkeley National Laboratory.

Badges  |  Report an Issue  |  Terms of Service