Kent Browning
  • Austin, TX
  • United States
Share on Facebook Share on Facebook Share
  • Blogs
  • Discussions (9)
  • Events
  • Groups
  • Photos
  • Photo Albums
  • Videos
 

Kent Browning's Page

Latest Activity

Kent Browning replied to Brandon Walton's discussion When is it too windy to use blower door?
"Thanks everyone for all the info! This has been VERY helpful. I have been reading how multi-point tests are LESS accurate than single point tests in high winds. I would not have expected that. Then it occurred to me that the single point test has no…"
Jul 27
Kent Browning replied to Brandon Walton's discussion When is it too windy to use blower door?
"I found this post thru a Google search. I was already a member and have posted a few times. I am a mechanical engineer who has been doing blower door tests for decades. I only do 10 to 15 BD test per year (I am not doing energy audits or such).I am…"
Jul 21
Kent Browning replied to Luis Hernandez's discussion ERV Configuration
"Rather than recommend an ERV, how about some thru wall exhaust fan(s) in the bath room(s)? Put them on timers so they don't run all the time. That kitchen fan REALLY needs to exhaust outside.  I would make that a higher priority than the…"
Sep 15, 2016
Kent Browning commented on Jan Green's blog post Wonky HVAC System
"This looks like a common type of system for Arizona.  Most of the time that package unit would be located on the roof and the ducts run down thru the roof. A lot of units installed that way were evap coolers that were replaced with an air…"
Sep 15, 2016
Kent Browning replied to Shaun 's discussion Commercial duct testing
"I agree with you so far.  But that just means that the vapor barrier is less leaky than the duct.  (If the vapor barrier was more leaky than the duct, the vapor barrier wouldn't move.)  But my experience and test data says that…"
Jun 12, 2016
Kent Browning replied to Shaun 's discussion Commercial duct testing
""Most sealing done on ductwork is the insulation"?  How do you figure that?  Do you have any data to support that idea?"
Jun 11, 2016
Kent Browning replied to Shaun 's discussion Commercial duct testing
"I run into this all the time.  You CAN test those ducts.  If you want a good quality installation - you should test those ducts and they should meet the leakage specified..  A typical installation leaks 30% of the air thru the…"
Jun 9, 2016
Kent Browning replied to Bachi Brunato's discussion Modeling a Gas Fireplace in Wrightsoft
"Wrightsoft has an option to include a fireplace in a zone.  I would use that option since it complies with the Manual J instructions.  If you use some other method (hole or heating source) you should make sure your method complies with…"
Aug 12, 2015
Kent Browning replied to Home Energy Magazine's discussion UV light in Furnace?
"UV lights have their place - but in my opinion are ridiculously oversold.  In order to do ANYTHING worthwhile they MUST shine directly on the evaporator coil / drain pan.  Any other location and they do nothing useful.  Only when the…"
Mar 20, 2014
Kent Browning replied to Joshua Lloyd's discussion Air Handler Fan Speed
"The fan speed needs to be set to provide the air flow to each room calculated by the Manual J.  It was rare to have a contractor do a manual J or adjust the fan speed until recently.  The City of Austin (Texas) required thru the energy…"
Jun 25, 2013
Kent Browning is now a member of Home Energy Pros
Dec 10, 2010

Profile Information

Company
KWR Engineering Services

Comment Wall (1 comment)

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

At 6:57am on December 11, 2010, Diane Chojnowski said…

Hi Kent,

Welcome to Home Energy Pros! Feel free to join the conversation in the Forum and Groups. And share your energy efficiency photos, videos and upcoming events. If you're blogging about home performance, this is the place for you!

Don't forget to upload your profile photo. And, add your location on our Member Map!

Thanks!
Diane, HEP Moderator

 
 
 

Forum Discussions

Origin of guarded blower door testing

Started by Kim Tanner in General Forum. Last reply by Eric Kjelshus 10 hours ago. 9 Replies

Electro Magnetic Fields (EMF)

Started by Barry L NewDelman in General Forum. Last reply by Daniel Cullen Aug 10. 5 Replies

When is it too windy to use blower door?

Started by Brandon Walton in General Forum. Last reply by Iain Walker Aug 10. 17 Replies

Latest Activity

Eric Kjelshus replied to Kim Tanner's discussion Origin of guarded blower door testing
"That same house that meet highest sealing rate in early 1980 we went back and super sealed it and…"
10 hours ago
Jill Cliburn posted an event
Thumbnail

National Solar Conference and NZE Decathlon at University of Colorado

October 9, 2017 at 6pm to October 12, 2017 at 7pm
10 hours ago
tedkidd replied to Kim Tanner's discussion Origin of guarded blower door testing
"Brendan, Eric, great stuff!"
11 hours ago
tedkidd liked Kim Tanner's discussion Origin of guarded blower door testing
11 hours ago

Photos

Loading…
  • Add Photos
  • View All

© 2017   Created by Lawrence Berkeley National Laboratory.   Powered by

Badges  |  Report an Issue  |  Terms of Service