Fixing a water heater?
15 Replies

I've been doing HP assessments for 12 years, but find myself a little limited in my knowledge of this issue.Here's the scenario: I do an initial assessment where I find a 7-year old NG water heater…Continue

Tags: plumber, CO, heater, water

Started this discussion. Last reply by Steven Turetsky Sep 2.

EPAct builder tax credit extension
11 Replies

Folks, I have gotten an email from RESNET stating that this has been extended and made retroactive to Jan. 1, 2010. Has anyone gotten more details on this yet? I want to make sure that there are no…Continue

Started this discussion. Last reply by Lorna G. Fear Jan 4, 2011.

 

John Shillito's Page

Latest Activity

Steven Turetsky replied to John Shillito's discussion Fixing a water heater?
"Hello John (and everyone else in the forum), I'm a new visitor at this forum and it this is my first post. I look forward to more sharing and learning in the future. The first condition that I would do is investigate the "weak…"
Sep 2
Larry Nissman replied to John Shillito's discussion Fixing a water heater?
"I have to agree with Kurt. 2000 ppm is exceedingly high. I have tested hundreds of hot water heater (NG, Oil) and mostly they come in around 16 ppm. There is clearly something wrong and we all know that a gas hot water draft can easily be…"
Jul 31
Kurt Albershardt replied to John Shillito's discussion Fixing a water heater?
"2000 ppm CO is not a problem?  Really?  In what universe?"
Jul 26
Matthew Lutz replied to John Shillito's discussion Fixing a water heater?
"hey thanks for the links. Very informative on FVIR units"
Jul 10
James P. Weingardt replied to John Shillito's discussion Fixing a water heater?
"The problem with a high CO in the flue is that if conditions such as floor movement, new fans installed in the house, insulation/air sealing issues may allow a system that already has high CO escape.  High CO will multiply when in a confined…"
Jul 5
John Shillito replied to John Shillito's discussion Fixing a water heater?
"Thanks to everyone for the great replies. I contacted the manufacturer, and the reply I was given by way of their technical department was that 2000 ppm CO is not a problem as long as it is venting properly out of the home. Testing for CO in the…"
Jun 24
Tom Delconte replied to John Shillito's discussion Fixing a water heater?
"Eric & Larry are both right , recorded here: http://waterheatertimer.org/How-to-troubleshoot-gas-water-heater.html  this site is super great!"
Jun 13
Brad Cook replied to John Shillito's discussion Fixing a water heater?
"A common cause that I have seen is undersized gas supply piping, especially when a combustion appliance is added to the line. Undersized gas supply pipe = lower gas pressure => high CO"
Jun 12
Eric Kjelshus replied to John Shillito's discussion Fixing a water heater?
"when we do cleaning for air conditioning or furnace work we also clean the air filter on the FVIR hot water heater.  look at my web sight under "peak"  HVAC  www.ericsenergy.com   I have seen 100's of full hot…"
Jun 12
Larry Weingarten replied to John Shillito's discussion Fixing a water heater?
"Hello:  If it's an FVIR heater, there can be restriction in the air intake caused by nearly invisible dust.  Washing off (or blowing off, or vacuuming) the intake screen and flame arrestor might not be a bad thing to do. …"
Jun 12
Tom Delconte replied to John Shillito's discussion Fixing a water heater?
"The homeowner is the expert! Assuming your CO meter is properly calibrated, the flue vent is not blocked, and the gas control valve is a-ok, it is strictly up to the homeowner to read the equipment manual, and go in and adjust the air shutter for a…"
Jun 11
Eric Kjelshus replied to John Shillito's discussion Fixing a water heater?
"9 ways to get high CO.  High presser low presser  impingement ( rust on burner- mis alined burner) to high flue presser lack of flue,  low temp very high temp. Flue to small or to cold   I find most plumber do not tune up hot…"
Jun 11
John Shillito replied to John Shillito's discussion Fixing a water heater?
"Bud, the weak draft was likely due to sharing a clay lined flue with a furnace. It was at an acceptable level."
Jun 11
John Shillito's discussion was featured

Fixing a water heater?

I've been doing HP assessments for 12 years, but find myself a little limited in my knowledge of this issue.Here's the scenario: I do an initial assessment where I find a 7-year old NG water heater with 1500 ppm undiluted CO. The homeowner brings in his plumber to "fix" it. The plumber, who doesn't own a CO monitor, cleans the burner and air intake grill, and proclaims it good. After work is done on the home, I re-test and find the CO to be even higher this time, and the draft weak.What…See More
Jun 10
Sean Lintow Sr replied to John Shillito's discussion Fixing a water heater?
"Wrong orifice for gas type? Bumped the burner knocking it out of alignment? Poor draft due to it cant pull as well due to air-sealing, etc... was a fresh air intake pipe added? Sorry but the only true & correct answer / fix which…"
Jun 8
Bud Poll replied to John Shillito's discussion Fixing a water heater?
"I'll let a pro (which I am not) jump in on the correct adjustment, but you said: "One thing I know is I need to align with a knowledgeable person to address this in the future." That is a mouth full and one of the major steps needed…"
Jun 7

Profile Information

Company
Home Energy Solutions
Professional Certification
HERS rater, BPI Building Analyst
Professional Interests
I work with homeowners on existing homes and builders with new construction.
Website URL
http://www.home-energy.biz
Facebook Page
jshillito1

Comment Wall (1 comment)

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

At 10:43am on December 20, 2010, Diane Chojnowski said…

Hi John,

Welcome to Home Energy Pros! Feel free to join the conversation in the Forum and Groups. And share your energy efficiency photos, videos and upcoming events. If you're blogging about home performance, this is the place for you!

Don't forget to upload your profile photo. And, add your location on our Member Map!

Thanks!
Diane, HEP Moderator

 
 
 

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.

Latest Activity

Ethan Bukowiec replied to Ethan Bukowiec's discussion Thoughts on energy startup's new propane smart meter
"Wanted to give everyone an update on how things are doing with our Kickstarter campaign. We have…"
15 hours ago
Tom White's video was featured

Unlocking the Power of Grey Water in a Living Building Challenge Home

Rob Nicely, President of Carmel Building & Design talks with Tom Wood, Nexus eWater System's Chief Technology Officer, about Unlocking the Power of Grey Water.
15 hours ago
Griffin Hagle's discussion was featured

You're designing a Home Performance dashboard. Which 6 metrics do you include?

Credit Karma got me thinking about this. For those who are unfamiliar, it's a free* online credit…See More
15 hours ago
Bud Poll's discussion was featured

Inconsistant Local Authority

It becomes frustrating to give people modern advice and then have to backtrack and tell them to do…See More
15 hours ago
w d's discussion was featured

Managing Solar Energy

What's the state of the art on managing solar energy (esp. at the home)?There's surely no…See More
15 hours ago
Ethan Bukowiec's discussion was featured

Thoughts on energy startup's new propane smart meter

Hello,I wanted to introduce you all to a new energy startup I am working with called …See More
15 hours ago
George Kopf's discussion was featured
15 hours ago
John Porterfield replied to Dave Robinson's discussion Can We PLEASE Stop Calling Them “Ductless” in the group 1000 Home Challenge
"Any update on this work?  Seems manufacturers would provide an indoor coil that would…"