TREAT modeling of mid-rise apartments low heating load

Started this discussion. Last reply by Don Hynek Jun 1. 4 Replies

Does anyone have experience using TREAT to model mid-rise (3-story) apartment buildings with interior corridors?  Our housing authority requires true-ing up the "calculate model" heating load…Continue

Tags: calibrating, up, trueing, modeling, TREAT

 

Jim Fowler's Page

Latest Activity

Don Hynek replied to Jim Fowler's discussion TREAT modeling of mid-rise apartments low heating load
"This isn't uncommon -- senior buildings often have lower-than-typical baseload use; especially for domestic hot water. More generally, though -- TREAT DOES have inputs for t-stat settings, water heater settings, space heating schedules, etc. I…"
Jun 1
John Nicholas replied to Jim Fowler's discussion TREAT modeling of mid-rise apartments low heating load
"So why is tenant behavior significantly different in this building?"
Apr 27
Jim Fowler replied to Jim Fowler's discussion TREAT modeling of mid-rise apartments low heating load
"Hi John - I'm strictly modeling the entire building, not individual units. I'm looking for a justifiable rationale to increase heating load to a more realistic level (based on observed apartment temperatures and my experience) to increase…"
Apr 27
John Nicholas replied to Jim Fowler's discussion TREAT modeling of mid-rise apartments low heating load
"Where is this going?  Are you (the housing authority) trying to set the Utility Allowance?  Somewhere else?   All electric?  Balanced Power?  Does each apt have specific DHW, heat and cool?  Are they metered…"
Apr 27
Diane Chojnowski left a comment for Jim Fowler
"Hi Jim, Welcome to Home Energy Pros. Feel free to join the conversation in the Forum and Groups. And share your energy efficiency photos, videos and upcoming events. If you're blogging about home performance, this is the place for…"
Apr 24
Jim Fowler posted a discussion

TREAT modeling of mid-rise apartments low heating load

Does anyone have experience using TREAT to model mid-rise (3-story) apartment buildings with interior corridors?  Our housing authority requires true-ing up the "calculate model" heating load consumption to the "calculate billing" heating load consumption.  TREAT's analysis of the monthly consumption figures come out with a baseload that's too high and heating load that's too low (8 kBTU/SF), I say this is based on temperatures observed during the site survey which show that the seniors in this…See More
Apr 21
Jim Fowler is now a member of Home Energy Pros
Apr 21

Profile Information

Company
Global Energy Audits, LLC
Role in Home Performance Marketplace
Building energy modeler, Energy auditor / assessor / analyst
Professional Certification
CEM
Website URL
http://www.globalenergyaudits.com

Comment Wall (1 comment)

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

At 7:26am on April 24, 2017, Diane Chojnowski said…

Hi Jim,

Welcome to Home Energy Pros. Feel free to join the conversation in the Forum and Groups. And share your energy efficiency photos, videos and upcoming events. If you're blogging about home performance, this is the place for you!

Don't forget to upload your profile photo.

Thanks!
Diane, HEP Moderator

 
 
 

Forum Discussions

Origin of guarded blower door testing

Started by Kim Tanner in General Forum. Last reply by Eric Kjelshus on Thursday. 9 Replies

Electro Magnetic Fields (EMF)

Started by Barry L NewDelman in General Forum. Last reply by Daniel Cullen Aug 10. 5 Replies

When is it too windy to use blower door?

Started by Brandon Walton in General Forum. Last reply by Iain Walker Aug 10. 17 Replies

Latest Activity

Profile IconArmstrong SMith, Eric Buchalter, Liza Gonzalez and 3 more joined Home Energy Pros
yesterday
Eric Kjelshus replied to Kim Tanner's discussion Origin of guarded blower door testing
"That same house that meet highest sealing rate in early 1980 we went back and super sealed it and…"
Thursday
Jill Cliburn posted an event
Thumbnail

National Solar Conference and NZE Decathlon at University of Colorado

October 9, 2017 at 6pm to October 12, 2017 at 7pm
Thursday
tedkidd replied to Kim Tanner's discussion Origin of guarded blower door testing
"Brendan, Eric, great stuff!"
Thursday

Photos

Loading…
  • Add Photos
  • View All

© 2017   Created by Lawrence Berkeley National Laboratory.   Powered by

Badges  |  Report an Issue  |  Terms of Service