I am sure this is a challenge that some of you have faced before:You have an air handling system with fresh air intake that is ducted into the return and is terminated on the outside in a way that…Continue
Started this discussion. Last reply by Dale Sherman Feb 7.
I am just wondering if a lot of people are feeling the way I do on the subject of testing Duct Leakage To Outside on duct systems that are fully within the envelope. And the way I feel is - it's…Continue
Started this discussion. Last reply by tedkidd May 3, 2012.
Here is a dilemma for a BPI-certified building auditor - should I or shouldn't I drill through a flue pipe of a power-vented combustion appliance? At first it seems obvious - don't. The BPI standards…Continue
Started this discussion. Last reply by David Meiland Mar 14, 2011.
George J. Nesbitt replied to Jack Baikoff's discussion Measuring fresh air intake ducted to a return and no way of measuring from outside.
Chris Clay replied to Jack Baikoff's discussion Measuring fresh air intake ducted to a return and no way of measuring from outside.
David Meiland replied to Jack Baikoff's discussion Measuring fresh air intake ducted to a return and no way of measuring from outside.
John Nicholas replied to Jack Baikoff's discussion Measuring fresh air intake ducted to a return and no way of measuring from outside.
John Nicholas replied to Jack Baikoff's discussion Measuring fresh air intake ducted to a return and no way of measuring from outside.
David Meiland replied to Jack Baikoff's discussion Measuring fresh air intake ducted to a return and no way of measuring from outside.
John Nicholas replied to Jack Baikoff's discussion Measuring fresh air intake ducted to a return and no way of measuring from outside.
John C. Semmelhack replied to Jack Baikoff's discussion Measuring fresh air intake ducted to a return and no way of measuring from outside.
George J. Nesbitt replied to Jack Baikoff's discussion Measuring fresh air intake ducted to a return and no way of measuring from outside.
John C. Semmelhack replied to Jack Baikoff's discussion Measuring fresh air intake ducted to a return and no way of measuring from outside.
John C. Semmelhack replied to Jack Baikoff's discussion Measuring fresh air intake ducted to a return and no way of measuring from outside.
John C. Semmelhack replied to Jack Baikoff's discussion Measuring fresh air intake ducted to a return and no way of measuring from outside.Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy, under the American Recovery and Reinvestment Act) and brought to you in partnership with Home Energy magazine.
yangxiaohua posted a blog post
Joe Huang posted a discussion
Tom Delconte commented on Tom Delconte's blog post Lykans $29, Vampires $0 !
Joseph Lamy commented on Jim Gunshinan's blog post The Universe Is Made of Stories
J.C. Martel replied to J.C. Martel's discussion Disasters & sustainable energy
Judi Lyall joined allen p tanner's group
Judi Lyall replied to David Starrett's discussion I am looking for a good IR camera in the group Energy Auditing Equipment for Sale, Trade or to Purchase© 2013 Created by Lawrence Berkeley National Laboratory.