Ethan Bodnaruk
  • Syracuse, NY
  • United States
Share on Facebook Share on Facebook Share
  • Featured Blogs
  • Discussions (5)
  • Events
  • Groups
  • Photos
  • Photo Albums
  • Videos

Ethan Bodnaruk's Discussions

Insulating with *Updated* (an oxymoron, right!) knob and tube wiring
8 Replies

Hi everyone,I live in New York State and haven't been able to find good information on whether or not we can get our house insulated.  I've searched the forums and internet, so please excuse me if…Continue

Tags: insulation, code, updated, tube, and

Started this discussion. Last reply by Ethan Bodnaruk Mar 29, 2014.

 

Ethan Bodnaruk's Page

Latest Activity

Ethan Bodnaruk just added their location.
(via Member Map)

Mar 29, 2014
Ethan Bodnaruk replied to Ethan Bodnaruk's discussion Insulating with *Updated* (an oxymoron, right!) knob and tube wiring
"That is very true!  We had a residential energy efficiency contractor come in (same people who found the K&T then turned tail and ran!) and it seemed like they took more of a "cookie cutter" approach.  They wanted to do wall…"
Mar 29, 2014
Diane Chojnowski left a comment for Ethan Bodnaruk
"Welcome to Home Energy Pros! Feel free to join the conversation in the Forum and Groups. And share your energy efficiency photos, videos and upcoming events. If you're blogging about home performance, this is the place for you! Don't…"
Mar 21, 2014
Ethan Bodnaruk's discussion was featured

Insulating with *Updated* (an oxymoron, right!) knob and tube wiring

Hi everyone,I live in New York State and haven't been able to find good information on whether or not we can get our house insulated.  I've searched the forums and internet, so please excuse me if I'm missing something obvious.  We have a 1929 house, but the trick is that we don't have the original K&T wiring.  The electrical system was updated a few decades ago (100 amp) and from what I understand, we have new wiring but have some junction boxes in the wall that still have some K&T.…See More
Mar 10, 2014
Ed Voytovich replied to Ethan Bodnaruk's discussion Insulating with *Updated* (an oxymoron, right!) knob and tube wiring
"Ethan . . . insulation is only the half of it:  it's especially important to do a good job of air sealing. If your wood burning stove takes its combustion air from inside the house, infiltration from inadequately air sealed details will…"
Mar 9, 2014
Ethan Bodnaruk replied to Ethan Bodnaruk's discussion Insulating with *Updated* (an oxymoron, right!) knob and tube wiring
"Thanks everyone.  It does seem like K&T unfairly gets a bad rap for safety, when alterations or overuse can be causes of fire but not normally functioning K&T.   We got a wood stove this season and it does a fair job heating the…"
Mar 9, 2014
Jim Baerg replied to Ethan Bodnaruk's discussion Insulating with *Updated* (an oxymoron, right!) knob and tube wiring
"I did a Web search on this recently; NEC prohibits covering K&T with insulation.  Must maintain a 3" air gap.  Some states, under the auspices of Bonneville Power, have amended that rule;  Calif, OR, WA, ID and also Nebraska.…"
Mar 6, 2014
Ed Voytovich replied to Ethan Bodnaruk's discussion Insulating with *Updated* (an oxymoron, right!) knob and tube wiring
" Ethan . . . 1929 is pretty late for knob and tube in new construction; it would be possible for a home inspector or even some electricians who are not experienced in homes of this vintage to mistake the heavy fabric jacketing on some types of…"
Mar 6, 2014
Ethan Bodnaruk replied to Ethan Bodnaruk's discussion Insulating with *Updated* (an oxymoron, right!) knob and tube wiring
"Hi Bud, Thanks for the info.  Unfortunately, our home inspector did not talk about K&T much, other than pointing out a couple places in the basement and attic where there was exposed K&T and pointing out that our electrical service had…"
Mar 5, 2014
Bud Poll replied to Ethan Bodnaruk's discussion Insulating with *Updated* (an oxymoron, right!) knob and tube wiring
"Hi Ethan, (my opinion) All wires have a temperature rating and K&T wires were not rated to be covered with insulation.  Since all K&T was not removed, you don't know where the old wiring is and is not.  Until that is…"
Mar 5, 2014
Ethan Bodnaruk replied to Ethan Bodnaruk's discussion Insulating with *Updated* (an oxymoron, right!) knob and tube wiring
"One more thing - our attic was insulated before we got the house, so how was this done if K&T is an issue???"
Mar 4, 2014
Ethan Bodnaruk posted a discussion

Insulating with *Updated* (an oxymoron, right!) knob and tube wiring

Hi everyone,I live in New York State and haven't been able to find good information on whether or not we can get our house insulated.  I've searched the forums and internet, so please excuse me if I'm missing something obvious.  We have a 1929 house, but the trick is that we don't have the original K&T wiring.  The electrical system was updated a few decades ago (100 amp) and from what I understand, we have new wiring but have some junction boxes in the wall that still have some K&T.…See More
Mar 4, 2014
Ethan Bodnaruk is now a member of Home Energy Pros
Mar 2, 2014

Profile Information

Company
SUNY-ESF
Professional Interests
Sustainability, Urban Forestry, Renewable Energy, Organic waste management, permaculture
Website URL
http://www.linkedin.com/pub/ethan-bodnaruk/58/75/261
Blog URL
http://www.ethanbodnaruk.com
Twitter ID
ethanbodnaruk

Comment Wall (1 comment)

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

At 12:45pm on March 21, 2014, Diane Chojnowski said…

Welcome to Home Energy Pros! Feel free to join the conversation in the Forum and Groups. And share your energy efficiency photos, videos and upcoming events. If you're blogging about home performance, this is the place for you!

Don't forget to add your profile photo and be sure to put your location on our Member Map!


Thanks!
Diane, HEP Moderator

 
 
 

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.  Home Energy Pros is sponsored by the Better Buildings Residential Network.

Latest Activity

Colin Genge's video was featured

Passive House Testing Webinar (Feb 13, 2014)

We covered: - Measuring air leakage in a tight house; - New passive house testing equipment; - Powered flow hoods for accurate measurement of HRV ERV flow ra...
2 hours ago
Colin Genge posted events
9 hours ago
John Nicholas replied to Sean Lintow Sr's discussion Duct Testing - is a change in order? in the group Best Practices (Residential)
"Yes,  I was connected to the AH cabinet.  I find it easier in this area, given the common…"
11 hours ago
Colin Genge replied to Kim Tanner's discussion Blower Door Applications Guide in the group Multifamily Buildings
"This is a great guide that anyone testing with multiple fans should get hold  of. "
12 hours ago
Colin Genge added a discussion to the group Multifamily Buildings
Thumbnail

Just posted a lot of Multi-Family oriented blower door videos.

Just posted a lot of Multi-Family oriented blower door videos. Everything to do with Multi-Fan…See More
12 hours ago
Colin Genge joined Norm Bourassa's group
Thumbnail

Multifamily Buildings

For too long there has been relatively little EE focus on multifamily, but some new programs have…See More
12 hours ago
Colin Genge replied to Sean Lintow Sr's discussion Duct Testing - is a change in order? in the group Best Practices (Residential)
"I would assume you tested that high air leakage from the equipment cabinet and not on a flex…"
12 hours ago
Colin Genge replied to Sean Lintow Sr's discussion Blower Doors & Methods Used in the group Best Practices (Residential)
"For those of you who need  a Tectite report, FanTestic's report Generator is powerful…"
12 hours ago

© 2015   Created by Lawrence Berkeley National Laboratory.

Badges  |  Report an Issue  |  Terms of Service