Eric Timon
  • Grand Rapids, MI
  • United States
Share on Facebook Share on Facebook Share Twitter
  • Featured Blogs
  • Discussions (4)
  • Events
  • Groups
  • Photos
  • Photo Albums
  • Videos

Eric Timon's Friends

  • Marg properties

Eric Timon's Discussions

BPI to Adopt ASHRAE Standard 62.2010?
13 Replies

Hello,I have received an email about how BPI is to adopt ASHRAE Standard 62.2-2010, replacing 62-89. Just wondering if anyone can explain what the difference between the two standards is and how it…Continue

Started this discussion. Last reply by Craig A. Lawson Jun 21, 2012.

Anything and Everything You Can Tell Me About Soy Foam Insulation?
1 Reply

Hello, I have a client interested in soy foam insulation. None of the insulators I have talked to have any experience with soy nor do they know anyone who uses it. I haven't researched it much yet…Continue

Started this discussion. Last reply by Sean Lintow Sr Oct 21, 2011.

 

Eric Timon's Page

Latest Activity

Craig A. Lawson replied to Eric Timon's discussion BPI to Adopt ASHRAE Standard 62.2010?
"Let us not forget that 62-89 does not exist anymore, and hasn't for over a year.  I'm glad to see BPI finally adopt this current standard, and get the non-existant standard off their…"
Jun 21, 2012
Michael Dunseith replied to Eric Timon's discussion BPI to Adopt ASHRAE Standard 62.2010?
"Pat, I agree, would love to see some marketing for the Home Performance Industry... Mike Homes is a great place to start. But I'm a fan of doing things myself and not counting on others. I'd like to see the contractors of NYS come together…"
Jun 16, 2012
Pat Dundon replied to Eric Timon's discussion BPI to Adopt ASHRAE Standard 62.2010?
"thanks again.  get it in the standard to 'decomission' fans that cannot be corrected if you can please.   inspectors tend to look at the world as black & white and refuse to consider greys.  also please get BPI to…"
Jun 14, 2012
Paul Raymer replied to Eric Timon's discussion BPI to Adopt ASHRAE Standard 62.2010?
"Hang in there, Pat.  Geez.  So much frustration!  If there is an existing fan venting into the structure of a cathedral ceiling or into the ceiling or into the attic, you know it is doing damage!  I worked on a house in NJ where…"
Jun 14, 2012
Pat Dundon replied to Eric Timon's discussion BPI to Adopt ASHRAE Standard 62.2010?
"most fans are rated without ducting attached.  a duct and a couple elbows will rapidly reduce a 100 cfm fan to 50 cfm.  at full speed.  that is why i said 100+ cfm fan."
Jun 14, 2012
Pat Dundon replied to Eric Timon's discussion BPI to Adopt ASHRAE Standard 62.2010?
"Thank you for this Paul.  I was on a webinar yesterday where either I heard the methodology for existing fans wrong,  or it was presented wrong.  Am I to understand from this that if an existing fan does not vent to outside, you must…"
Jun 14, 2012
Paul Raymer replied to Eric Timon's discussion BPI to Adopt ASHRAE Standard 62.2010?
"There is a great deal of furor about the ASHRAE 62.2-2010 Standard a lot of which comes from only looking at parts of the Standard.  Like a house, the Standard is a system and should be taken as a whole. Having said that, I want to look at a…"
Jun 14, 2012
Brennan Less replied to Eric Timon's discussion BPI to Adopt ASHRAE Standard 62.2010?
"Pat, you will almost never need a 100 cfm continuous fan to meet 62.2, unless the home is very large (>3,500 ft2).  Whole house mechanical ventilation rates are on the order of 0.17 ACH, which is usually in the 35-60 cfm range.  Much…"
Jun 14, 2012
Pat Dundon replied to Eric Timon's discussion BPI to Adopt ASHRAE Standard 62.2010?
"There are three markets here. New construction, where everything is planned and budgeted before anything is done, Wx, where the budget question does not involve the client and profit is not necessary,and retrofit, where the client's budget…"
Jun 14, 2012
David Meiland replied to Eric Timon's discussion BPI to Adopt ASHRAE Standard 62.2010?
"There's a fairly cheap "Exhaust Fan Flow Meter" from Energy Conservatory that's worth owning, and if you don't want to buy theirs I've seen instructions for a home-made version. I have the TEC product, use it, and like…"
Jun 13, 2012
Sean Lintow Sr replied to Eric Timon's discussion BPI to Adopt ASHRAE Standard 62.2010?
"Sorry I have got to say it - you (generically stated) all are great at parroting the mantra "THE HOUSE IS A SYSTEM" & then you promptly forget all about it when you do your SIRS & payback equations. Christ I saw…"
Jun 13, 2012
Pat Dundon replied to Eric Timon's discussion BPI to Adopt ASHRAE Standard 62.2010?
"I am in NY. We have a retrofit program active now for those folks too high income for weatherization, but not rich. It is crippled by the Public Service Commission because the law said the work has to meet a payback based on the 'savings on the…"
Jun 13, 2012
Sean Lintow Sr replied to Eric Timon's discussion BPI to Adopt ASHRAE Standard 62.2010?
"Sure 89 is toast & 62.2's formula is (Total square foot of a home/100) + (Number of bedrooms + 1) x 7.5 cfm)Now if you want to delve into a ton of the arguments about it - Carl Seville posted an interesting email thread about it as it…"
Jun 13, 2012
Eric Timon posted a discussion

BPI to Adopt ASHRAE Standard 62.2010?

Hello,I have received an email about how BPI is to adopt ASHRAE Standard 62.2-2010, replacing 62-89. Just wondering if anyone can explain what the difference between the two standards is and how it affects energy auditors who are currently using 62-89?Thanks!EricSee More
Jun 13, 2012
Eric Timon replied to Tim Marlett's discussion Building Airflow Standards and the Average Contractor
"Thanks Patrick, the home I was speaking of was built in 1993, I don't know anything about the builder but he certainly did something right that beyond what our 3 hour assessment could see. We have also recently tested all our our blower door…"
Apr 27, 2012
Eric Timon replied to Tim Marlett's discussion Building Airflow Standards and the Average Contractor
"This is something I have been battling for awhile now. For me it is hard to explain the building airflow standard to clients without them becoming concerned about too tight of a home. It is important to explain that the standard is not necessarily…"
Apr 25, 2012

Profile Information

Company
DwellTech Solutions
Website URL
http://www.dwelltechsolutions.com

Comment Wall (1 comment)

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

At 6:51am on March 27, 2011, Diane Chojnowski said…

Hi Eric,

Welcome to Home Energy Pros! Feel free to join the conversation in the Forum and Groups. And share your energy efficiency photos, videos and upcoming events. If you're blogging about home performance, this is the place for you!

Don't forget to upload your profile photo. And add your location on our Member Map!


Thanks!
Diane, HEP Moderator

 
 
 

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.

Latest Activity

Tom Delconte commented on Kurt Shafer's blog post What is your opinion about members promoting products here?
"Shameless self promotion here sucks like a leaky duck!"
1 hour ago
Profile IconJohn A Deuth, Lisa M. Harr and Ramon Aguirre joined Home Energy Pros
1 hour ago
Don Fitchett posted a blog post

Small Businesses: Diversify with Infrared Thermography Services, Save Your Business, Save the Country...

HERS should all offer Infrared Thermography Services.It is all ways great advice for small…See More
12 hours ago
Richard Beyer replied to Mike Kandel's discussion Our Homes Suck – And That's Why Our Kids Have Sinus Problems
""There are thousands of potential harmful products that can contribute to existing homes poor…"
13 hours ago
Richard Beyer replied to Mike Kandel's discussion Our Homes Suck – And That's Why Our Kids Have Sinus Problems
"Barbara, We both know a fan switch will only conserve on energy. What is Berkeley devising to clean…"
13 hours ago
Richard Beyer replied to Mike Kandel's discussion Our Homes Suck – And That's Why Our Kids Have Sinus Problems
"Ted no one can help anyone with their head stuck in the sand. All you said is MONEY is your God.…"
13 hours ago
Richard Beyer replied to Richard Beyer's discussion Spontaneous Combustion and Flash Fire regarding Spray Foam Insulation
"Hal, Thank you for laying out those facts. Fire safety is just as important of an issue as energy…"
13 hours ago
Don Fitchett commented on Diane Chojnowski's group Facebook Pages
"I just went through the 1st 2 pages of member's facebook pages liking them. While our training…"
15 hours ago
Don Fitchett joined Diane Chojnowski's group
Thumbnail

Facebook Pages

Does your company or organization have a Facebook Page?This group is for pros who have facebook…See More
15 hours ago
Mike Kandel added 3 discussions to the group Building Performance Institute (BPI)
16 hours ago
Mike Kandel posted discussions
16 hours ago
EnergyLogic Academy updated an event

RESNET Phase 2 Rater Training - Field Training at EnergyLogic Academy - Berthoud CO

September 22, 2014 to September 24, 2014
The EnergyLogic Academy will be hosting the second phase of HERS Rater Training August 4th - 7th,…See More
16 hours ago

© 2014   Created by Lawrence Berkeley National Laboratory.

Badges  |  Report an Issue  |  Terms of Service