Eric Sperline
  • Male
  • Renton, WA
  • United States
Share on Facebook Share on Facebook Share

Eric Sperline's Friends

  • Pam Worner
  • Tyson Pischel

Eric Sperline's Groups

Eric Sperline's Discussions

Blower Door Testing for Code Compliance
13 Replies

I am interested to know how those who include blower door testing of new homes as a part of their business are able to maintain that service as a part of their business.I am probably very very naive…Continue

Started this discussion. Last reply by Donald Jahnke Jul 23.

Third party testing rqmt
2 Replies

I'm interested to know if the State you live in requires Blower door testing of the residential building envelope on new construction?Here in Washington State the Code official in the jurisdiction…Continue

Started this discussion. Last reply by Eric Sperline Dec 13, 2013.

Floor insulation attachment
16 Replies

I'm wondering if anyone out there has come across specific language for the attachment of fiberglass insulation over an unconditioned crawl space.  I realize there are various ways to accomplish…Continue

Started this discussion. Last reply by Robert Riversong Oct 18, 2012.

Hot water re-circ systems
18 Replies

For those of you who are conducting residential energy assessments; are you recommending "on demand"  hot water re-circ. systems?  I'm finding that many of my customers waste a ton of water while…Continue

Started this discussion. Last reply by tedkidd Apr 28, 2012.

 

Eric Sperline's Page

Latest Activity

Donald Jahnke replied to Eric Sperline's discussion Blower Door Testing for Code Compliance
"Training and products are definitely the key. I work with SIP installers and after more than 200 blower doors my worst is 1.15 and the lowest is .2 ACH 50 I use a C ring regularly and have a D ring as well. I have just tested a 1500 sq ft home with…"
Jul 23
Eric Sperline replied to Eric Sperline's discussion Blower Door Testing for Code Compliance
"I fully agree with you re: allowable tolerances. For one thing a difference of .01 in a test result could be the difference from gauge to gauge. In my opinion without a tolerance level we encourage false reporting. In addition it seems strange to me…"
Jul 17
Eric Sperline replied to Eric Sperline's discussion Blower Door Testing for Code Compliance
"Good point but realize my concern is after the home is finished. Now we're talking big bucks to dismantle and apply proper sealing measures."
Jul 17
Paul Raymer replied to Eric Sperline's discussion Blower Door Testing for Code Compliance
"Here in MA, the code requires 3 ACH50.  Despite concerted effort to make the builders aware of both the blower door test requirement in the code and what it takes to get the building tight, builders are suddenly shocked when the inspector…"
Jul 17
Colin Genge replied to Eric Sperline's discussion Blower Door Testing for Code Compliance
"Cost to get 5 airchanges is neglible.  Our experience world wide is that after the third house their costs are the same and might even go down if they use more efficient methods and materials.  Airsealing should be done during construction…"
Jul 16
Eric Sperline replied to Eric Sperline's discussion Blower Door Testing for Code Compliance
"Interesting concept, Colin. One thought that comes to mind however is that depending on the complexity of the structure, the cost to make the necessary modifications may exceed the estimated loss in heating/cooling costs. Those costs might be…"
Jul 16
Colin Genge replied to Eric Sperline's discussion Blower Door Testing for Code Compliance
"As much as I hate attorneys, I would link up with one, offer free tests to homeowners who just bought a house and let the attorney sue the builder when the house fails. They do that a lot in Europe and guess what, most houses get tested…"
Jul 16
Eric Sperline's discussion was featured

Blower Door Testing for Code Compliance

I am interested to know how those who include blower door testing of new homes as a part of their business are able to maintain that service as a part of their business.I am probably very very naive but as a tester I pride myself in accurate test results. In our State the builder must test a new home to an 5 ACH @ 50 pa. The problem is that many I test for are not reaching that level of envelope tightness.  I do not as a rule provide them with a passing test doc. for submittal to their building…See More
Jul 14
Sean Lintow Sr replied to Eric Sperline's discussion Blower Door Testing for Code Compliance
"A few quick thoughts - always provide the test results on the same type of report - in my case Pass or Fail along with the numbers is bolded & easy to spot --- As for retesting, there are no cost savings to me to come back so the charge is the…"
Jul 10
Eric Sperline replied to Eric Sperline's discussion Blower Door Testing for Code Compliance
"Good call."
Jul 10
David Meiland replied to Eric Sperline's discussion Blower Door Testing for Code Compliance
"Eric, you never know, the building inspectors may not be dinging builders for failing blower door tests. Building inspectors have to go head to head with builders on many items during construction, and they may not choose to make a sticking point…"
Jul 9
Bud Poll replied to Eric Sperline's discussion Blower Door Testing for Code Compliance
""they don't" would be my guess as well.  Unfortunately I tried to retire and have yet to get back into business.  In between the rules have changed so I did not run into this before and I'm reading posts like yours very…"
Jul 9
Eric Sperline replied to Eric Sperline's discussion Blower Door Testing for Code Compliance
"Hi Bud most of these builders are those that I have never met before.  They call me because their inspector told them the test was required.  One method I have tried without much success yet is to tell them that if they will have me in to…"
Jul 9
Bud Poll replied to Eric Sperline's discussion Blower Door Testing for Code Compliance
"Hi Eric, The solution I see is to convince those builders to utilize blower door testing during the construction process to ensure the final test will pass.  Certainly a failing report should be a motivator, but pushing that button makes it…"
Jul 9
Eric Sperline posted a discussion

Blower Door Testing for Code Compliance

I am interested to know how those who include blower door testing of new homes as a part of their business are able to maintain that service as a part of their business.I am probably very very naive but as a tester I pride myself in accurate test results. In our State the builder must test a new home to an 5 ACH @ 50 pa. The problem is that many I test for are not reaching that level of envelope tightness.  I do not as a rule provide them with a passing test doc. for submittal to their building…See More
Jul 9
Eric Sperline commented on Christopher Morin's blog post UPDATED: Big Changes for Duct Testing in MA
"Hello Chris, thank you for your post on duct testing rqm'ts in MA.  The tone of your message seems to be indicative of your position on the value of energy efficiency overall.  You use terms such as "stringent updated code…"
Aug 25, 2014

Profile Information

Company
Washington Energy Audits
Professional Certification
BPI, HERS, PTCS
Professional Interests
Residential/commercial energy audits, Blower door testing, Duct testing
Website URL
http://www.washingtonenergyaudits.com
Facebook Page
Washington Energy Audits
LinkedIn Profile
Eric Sperline

Comment Wall (3 comments)

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

At 7:13pm on April 13, 2012, Tyson Pischel said…

Looking forward to heading back your way soon.  I am really curious to know your take on the ventilation strategy that Kleiman used in the homes for Pioneer Pacific.  Do you know where they came up with that system?

At 10:26am on March 27, 2012, Bob Freer said…

Hi, Eric.  I have a Testo 327 that has only been used 5 or 6 times.  I'm willing to sel it for $700.  I know it is not exactly what you are looking for, but if you are interested, call me.  I'm in Tukwila.  You can reach me at 253-508-3542.

Bob

At 11:23am on November 8, 2011, Diane Chojnowski said…

Hi Eric,

Welcome to Home Energy Pros! Feel free to join the conversation in the Forum and Groups. And share your energy efficiency photos, videos and upcoming events. If you're blogging about home performance, this is the place for you!

Don't forget to upload your profile photo. And add your location on our Member Map!


Thanks!
Diane, HEP Moderator

 
 
 

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.  Home Energy Pros is sponsored by the Better Buildings Residential Network.

Latest Activity

Profile IconBenney Dornevil, Mike Norvell Sr and Jen Loomis joined Home Energy Pros
18 hours ago
Joanie Minor posted a status
"Home Performance Institute now offers OSHA 10 and Confined Space Classes. Call 203-536-2151 to register."
19 hours ago
Joanie Minor posted a photo
19 hours ago
John Kaye posted a blog post

FREE Home Efficiency & Safety Assessments in the Los Angeles County area.

Since last June I have been qualifying homeowners in the Los Angeles County for the Home Upgrade…See More
yesterday
Eric Kjelshus replied to Rod Fox's discussion Does calcification affect electric water heater aquastat temperature sensor performance?
"Those 240 Volt aquastats shut off and then on kinda quick back on.  The older the tank the…"
yesterday
Rod Fox replied to Rod Fox's discussion Does calcification affect electric water heater aquastat temperature sensor performance?
"Well I'd love to tell you folks I found an answer, but I did not... I went to my…"
yesterday
Rod Fox replied to Kevin Eigel's discussion What is the best energy auditing software?
"I've been trying to answer this question for many years and have not yet found an answer.…"
yesterday
Jerry Lawrence posted events
yesterday

© 2015   Created by Lawrence Berkeley National Laboratory.

Badges  |  Report an Issue  |  Terms of Service