David Berg
  • North Wales, PA
  • United States
Share on Facebook Share on Facebook Share

David Berg's Groups

 

David Berg's Page

Latest Activity

David Berg replied to John Nicholas's discussion ZERH to Begin Construction in the group News & Announcements
"I worked on a ZERH home in 2012 and 2013, and it was a new 2x6 framed structure on an existing foundation.  The home was built in Cape May NJ.   The insulation levels were R21 Fiberglass in the wall cavities with a 1/2 inch foam…"
Oct 30, 2015
David Berg joined Diane Chojnowski's group
Thumbnail

News & Announcements

Share your news and announcements with the community in this group.To post news or an announcement, please start a new discussion. See More
Oct 30, 2015
David Berg replied to Patrick Michaelyan's discussion Insulating the "walls" of a mansard-style roof.
"If the sheathing is being removed, then installing a layer of rigid foam under new sheathing is appropriate.  There should be a non condensing insulation layer adjacent to the "roof" sheathing.  In the DC climate zone this is…"
Dec 5, 2013
David Berg replied to Mike Kandel's discussion BPI's October Stump the Chump! in the group Building Performance Institute (BPI)
"looking at the information provided: 1 - is the system a multistage unit to better match load as well as zoning demands. 2 - is the heating capacity properly matched to to home demand - does the backup heat run? 3 - is the cooling capacity too large…"
Oct 26, 2012
David Berg joined Leslie McDowell, BPI's group
Thumbnail

Building Performance Institute (BPI)

BPI is the nation's premier standards development, quality assurance and credentialing organization for residential energy efficiency retrofit work.See More
Oct 26, 2012
David Berg replied to Bob Blanchette's discussion Cooling blower off delay vs. Humidity
"Good question. According to the technical documents the humidistat can be wired in and call for cooling operation with the the blower operation profile that is setup on the dip switches. "
Jun 29, 2012
David Berg replied to Bob Blanchette's discussion Cooling blower off delay vs. Humidity
"This unit is a TRANE UY120R9V5V gas furnace installed with a 5 ton Trane coil and 4 ton Trane compressor."
Jun 29, 2012
David Berg replied to Bob Blanchette's discussion Cooling blower off delay vs. Humidity
"My home also has variable speed blower and a special blower setting to maximize system performance and moisture extraction.  I have attached an extraction from the air handler documentation showing how the blower operation can be moderated.…"
Jun 29, 2012
David Berg replied to Bob Blanchette's discussion Cooling blower off delay vs. Humidity
"Some manufacturers have a ramp down and in some cases a ramp up fan behavior (variable speed blowers) that run at lower speeds for a few minutes at the end and beginning of the cooling cycle to extract more moisture from the air stream.  This…"
Jun 28, 2012

David Berg just added their location.
(via Member Map)

Mar 26, 2012
David Berg commented on Ed Voytovich's blog post NOx NOx "Who's There?"
"In my Testo 327-2 analyzer, there is a NO filter that removes the NO before the CO sensor.  It is one of the maintenance items that has to be replaced when the absorbing chemical is consumed.  Are you concerned about the CO readings or the…"
Mar 26, 2012
David Berg updated their profile photo
Dec 16, 2010
David Berg is now a member of Home Energy Pros
Nov 30, 2010

Profile Information

Company
DSB Energy Services LLC
Role in Home Performance Marketplace
Energy auditor / assessor / analyst
Professional Certification
HERS Rater
Website URL
http://www.dsbenergy.com

Comment Wall

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

  • No comments yet!
 
 
 

Videos

  • Add Videos
  • View All

Twitter

Latest Activity

Sean Lintow Sr replied to Larry Nissman's discussion Foam insulation on attic floor
"The insulation job is quite simply a freaking eyesore & mess - with that it shouldn't be…"
5 hours ago
Sean Lintow Sr replied to Melissa Baldridge's discussion IECC 2012 & 2015 Compliance & HRVs
"commercial is 67% efficiency & 2.8 cfm per watt for residential as I recall on 2015 which…"
5 hours ago
Simon added a discussion to the group Energy Auditing Equipment for Sale, Trade or to Purchase
Thumbnail

Advice needed please

I'm looking to build my own blower unit for use with the minneapolis system.Please could anyone…See More
8 hours ago
Simon joined Kim Tanner's group
Thumbnail

TEC

Discussion group for The Energy ConservatoryHave a question about residential or big building air…See More
8 hours ago
Rob Madden, Solar Home Broker replied to Rob Madden, Solar Home Broker's discussion Indoor Air Quality Monitors and Meters
"With a Foobot, are you able to recalibrate the sensors?  While I like the price and the…"
21 hours ago
Steve Mann replied to Steve Mann's discussion Eliminator EF400 Smoke Machine in the group Energy Auditing Equipment for Sale, Trade or to Purchase
"Yes it is. Steve"
yesterday
Laurie DiDonato updated an event
Thumbnail

Become a HERS Rater with the NE HERS Alliance this fall! at Classroom Component at Energize Connecticut Center

September 19, 2016 at 9am to October 21, 2016 at 5pm
Online Component: September 19th-30th - Weekdays 9am-12pm5-Day Classroom/Field Training:October…See More
yesterday
Melissa Baldridge posted a discussion

IECC 2012 & 2015 Compliance & HRVs

 I’m failing IECC 2012 with the HRVs we’ve been using – Honeywell .  (See specs below that I…See More
yesterday

© 2016   Created by Lawrence Berkeley National Laboratory.   Powered by

Badges  |  Report an Issue  |  Terms of Service