Dan Wise's Discussions

Convert BTU/hr in a Manual J to actual fuel usages

Started this discussion. Last reply by eric anderson Jun 19, 2014. 13 Replies

I cannot find any conversion table that translates the BTU/hr heat loss in a Manual J report to the amount of fuel required to heat the building to the design temperature.  In this case I'm using…Continue

 

Dan Wise's Page

Latest Activity

Diane Chojnowski left a comment for Dan Wise
"Welcome to Home Energy Pros! Feel free to join the conversation in the Forum and Groups. And share your energy efficiency photos, videos and upcoming events. If you're blogging about home performance, this is the place for you! Don't…"
Jun 29, 2014
eric anderson replied to Dan Wise's discussion Convert BTU/hr in a Manual J to actual fuel usages
"Morgan, From the perspective of the energy auditor, I don’t agree with that statement. “Actual fuel and electrical usage" is anecdotal at best” Unless you change something, the best predictor of future energy usage is past…"
Jun 19, 2014
Morgan M Audetat replied to Dan Wise's discussion Convert BTU/hr in a Manual J to actual fuel usages
""Actual fuel and electrical usage" is anecdotal at best. Bin is the thing and ASHRAE/Manual 'J' have the average weather data relevant to the building site.  The operate can cheat the numbers to add what ever he likes, but…"
Jun 18, 2014
eric anderson replied to Dan Wise's discussion Convert BTU/hr in a Manual J to actual fuel usages
"Bud, I think these 2 articles will help illustrate the difficulties of modeling energy usage. http://www.nrel.gov/docs/fy11osti/51603.pdf http://www.sustainablybuilt.com/SB_Modeling_Software_Presentation.pdf The first speaks to the common …"
Jun 18, 2014
Bud Poll replied to Dan Wise's discussion Convert BTU/hr in a Manual J to actual fuel usages
"Hi Morgan, I have admitted my lack of knowledge concerning Manual J and even worse, I approach heat loss from an energy auditor perspective, somewhat different from the HVAC approach. Example, we have no need to break down heat loss to room by room…"
Jun 17, 2014
Morgan M Audetat replied to Dan Wise's discussion Convert BTU/hr in a Manual J to actual fuel usages
"I use Wrightsoft to design HVAC systems, which is base on ACCA Manual 'J' heat load data.  My experience over the last 40 years has not been that over-sizing results from people depending on any Manual 'J' calculation…"
Jun 17, 2014
Bud Poll replied to Dan Wise's discussion Convert BTU/hr in a Manual J to actual fuel usages
"Hi again, Just to be clear, I wasn't questioning the person who did the MJ work, but I was questioning MJ itself as I do not know if or where those factors mentioned are included. There's another distinction between loss at design temp and…"
Jun 15, 2014
eric anderson replied to Dan Wise's discussion Convert BTU/hr in a Manual J to actual fuel usages
"Bud, The question was how to translate- from design heat loss calculated by using  ACCA manual J protocol to a yearly fuel usage.   I outlined a crude way to do it.  Is it perfect? Nope.  There are a lot of caveats to…"
Jun 15, 2014
Bud Poll replied to Dan Wise's discussion Convert BTU/hr in a Manual J to actual fuel usages
"Hi eric, Before we can reverse engineer that peak heat loss number from the manual J (MJ) report we need to know what they included when calculating it.  MJ is noted for over-estimating the appliance size, so has the 51,000 btus/hr number…"
Jun 15, 2014
Bob Blanchette replied to Dan Wise's discussion Convert BTU/hr in a Manual J to actual fuel usages
"The issues is you size for PEAK, not AVERAGE conditions. This will vary by location, some areas have more constant weather than others. I have NEVER seen a heating system that was too small to do the job, I have seen MANY that are 3X the required…"
Jun 14, 2014
eric anderson replied to Dan Wise's discussion Convert BTU/hr in a Manual J to actual fuel usages
"Dan, As a ballpark figure, take the design heat loss and divide by design temp difference, this gives you btu’s per °F per hour.  Multiply this number by 24 hours (per day) and then multiply by heating degree days to get yearly …"
Jun 13, 2014
Dan Wise's discussion was featured

Convert BTU/hr in a Manual J to actual fuel usages

I cannot find any conversion table that translates the BTU/hr heat loss in a Manual J report to the amount of fuel required to heat the building to the design temperature.  In this case I'm using propane and I have calculated the 92,000 BTU/gal using the actual BTU/Hr X Degree Days and end up requiring over 30K gallons of propane for a heating system.  This cannot be correct.  Any guidance would be greatly appreciated.See More
Jun 10, 2014
Bud Poll replied to Dan Wise's discussion Convert BTU/hr in a Manual J to actual fuel usages
"If 51,000 is your actual heat loss at the design temperature then you need a system capacity of 51,000 BTUs running continuously to maintain the set temperature.  A 60,000 BTU boiler running at 95% efficiency would just barely keep up. …"
Jun 10, 2014
Dan Wise replied to Dan Wise's discussion Convert BTU/hr in a Manual J to actual fuel usages
"Hi Bud,  My total heat loss per hour is 51,000 BTU/Hr with a design temperature difference of 48 degrees.  I am using 3900 degree days to figure the heating requirements.   Thanks for any guidance you may provide. Thanks,  Dan"
Jun 10, 2014
Bud Poll replied to Dan Wise's discussion Convert BTU/hr in a Manual J to actual fuel usages
"Hi Dan, That would be close to correct if every day was at the design temperature.  I don't use Manual J, so tell me what you have for the design temperature heat loss per hour and then the total heat loss per year at your local HDD. Bud"
Jun 9, 2014
Dan Wise posted a discussion

Convert BTU/hr in a Manual J to actual fuel usages

I cannot find any conversion table that translates the BTU/hr heat loss in a Manual J report to the amount of fuel required to heat the building to the design temperature.  In this case I'm using propane and I have calculated the 92,000 BTU/gal using the actual BTU/Hr X Degree Days and end up requiring over 30K gallons of propane for a heating system.  This cannot be correct.  Any guidance would be greatly appreciated.See More
Jun 9, 2014

Profile Information

Company
Grand Design Group
Professional Certification
CGP
Professional Interests
National Green Building Standard consulting and verification services.
Construction Management and Project Planning
Website URL
http://www.granddesigngroup.us

Comment Wall (1 comment)

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

At 1:32pm on June 29, 2014, Diane Chojnowski said…

Welcome to Home Energy Pros! Feel free to join the conversation in the Forum and Groups. And share your energy efficiency photos, videos and upcoming events. If you're blogging about home performance, this is the place for you!

Don't forget to add your profile photo and be sure to put your location on our Member Map!


Thanks!
Diane, HEP Moderator

 
 
 

Featured Forum Discussions

Too many BTU's. Too much horsepower?

Started by Steve in General Forum. Last reply by Eric Kjelshus 9 hours ago. 4 Replies

Stack/wind pressure and flow networks.

Started by Daniel James Grundy in Training. Last reply by Daniel James Grundy yesterday. 5 Replies

BDT with vermiculite in hollow CMU walls?

Started by Brad Cook in General Forum. Last reply by John Nicholas yesterday. 2 Replies

Strange IR Image

Started by Larry Nissman in General Forum. Last reply by Brad Cook Mar 9. 7 Replies

Videos

  • Add Videos
  • View All

Latest Activity

Eric Kjelshus replied to Steve's discussion Too many BTU's. Too much horsepower?
"Its more about run time with high RH removing, than to large over sized AC unit, in houses.  …"
9 hours ago
Sarah OConnell posted a blog post

Crowdsourcing for Innovation

Share Your Ideas!Novel Building Envelope Design for Increased Thermal PerformanceIn 2014, more than…See More
23 hours ago
Colin de Paor is now a member of Home Energy Pros
yesterday
Walter Ahlgrim replied to Steve's discussion Too many BTU's. Too much horsepower?
"The 5 ton system you have is not 500 hp racecar engines they are 500 hp truck engines. The duct…"
yesterday
Daniel James Grundy replied to Daniel James Grundy's discussion Stack/wind pressure and flow networks.
"So I wanted to start with a basic who can help then go into more detail later. But yes find…"
yesterday
Daniel James Grundy replied to Daniel James Grundy's discussion Stack/wind pressure and flow networks.
"My tutor got back to me and while areas don't quite feel right a little to much assumptions…"
yesterday
Brennan Less replied to Daniel James Grundy's discussion Stack/wind pressure and flow networks.
"Daniel, I'm assuming you're trying to predict the airflows through the different openings…"
yesterday
Martin Newmark joined allen p tanner's group
Thumbnail

Energy Auditing Equipment for Sale, Trade or to Purchase

Discuss the pros and cons of the equipment you are interested in prior to purchase. Post equipment…See More
yesterday

Home Energy Pros

Welcome to Home Energy Pros – the unique digital community by and for those who work in the home energy performance arena.

Home Energy Pros was founded by the developers of Home Energy Saver Pro (supported by the U.S. Department of Energy) and brought to you in partnership with Home Energy magazine.  Home Energy Pros is sponsored by the Better Buildings Residential Network. Please honor our Guidelines

© 2017   Created by Lawrence Berkeley National Laboratory.   Powered by

Badges  |  Report an Issue  |  Terms of Service