Convert BTU/hr in a Manual J to actual fuel usages
13 Replies

I cannot find any conversion table that translates the BTU/hr heat loss in a Manual J report to the amount of fuel required to heat the building to the design temperature.  In this case I'm using…Continue

Started this discussion. Last reply by eric anderson Jun 19.

 

Dan Wise's Page

Latest Activity

Diane Chojnowski left a comment for Dan Wise
"Welcome to Home Energy Pros! Feel free to join the conversation in the Forum and Groups. And share your energy efficiency photos, videos and upcoming events. If you're blogging about home performance, this is the place for you! Don't…"
Jun 29
eric anderson replied to Dan Wise's discussion Convert BTU/hr in a Manual J to actual fuel usages
"Morgan, From the perspective of the energy auditor, I don’t agree with that statement. “Actual fuel and electrical usage" is anecdotal at best” Unless you change something, the best predictor of future energy usage is past…"
Jun 19
Morgan M Audetat replied to Dan Wise's discussion Convert BTU/hr in a Manual J to actual fuel usages
""Actual fuel and electrical usage" is anecdotal at best. Bin is the thing and ASHRAE/Manual 'J' have the average weather data relevant to the building site.  The operate can cheat the numbers to add what ever he likes, but…"
Jun 18
eric anderson replied to Dan Wise's discussion Convert BTU/hr in a Manual J to actual fuel usages
"Bud, I think these 2 articles will help illustrate the difficulties of modeling energy usage. http://www.nrel.gov/docs/fy11osti/51603.pdf http://www.sustainablybuilt.com/SB_Modeling_Software_Presentation.pdf The first speaks to the common …"
Jun 18
Bud Poll replied to Dan Wise's discussion Convert BTU/hr in a Manual J to actual fuel usages
"Hi Morgan, I have admitted my lack of knowledge concerning Manual J and even worse, I approach heat loss from an energy auditor perspective, somewhat different from the HVAC approach. Example, we have no need to break down heat loss to room by room…"
Jun 17
Morgan M Audetat replied to Dan Wise's discussion Convert BTU/hr in a Manual J to actual fuel usages
"I use Wrightsoft to design HVAC systems, which is base on ACCA Manual 'J' heat load data.  My experience over the last 40 years has not been that over-sizing results from people depending on any Manual 'J' calculation…"
Jun 17
Bud Poll replied to Dan Wise's discussion Convert BTU/hr in a Manual J to actual fuel usages
"Hi again, Just to be clear, I wasn't questioning the person who did the MJ work, but I was questioning MJ itself as I do not know if or where those factors mentioned are included. There's another distinction between loss at design temp and…"
Jun 15
eric anderson replied to Dan Wise's discussion Convert BTU/hr in a Manual J to actual fuel usages
"Bud, The question was how to translate- from design heat loss calculated by using  ACCA manual J protocol to a yearly fuel usage.   I outlined a crude way to do it.  Is it perfect? Nope.  There are a lot of caveats to…"
Jun 15
Bud Poll replied to Dan Wise's discussion Convert BTU/hr in a Manual J to actual fuel usages
"Hi eric, Before we can reverse engineer that peak heat loss number from the manual J (MJ) report we need to know what they included when calculating it.  MJ is noted for over-estimating the appliance size, so has the 51,000 btus/hr number…"
Jun 15
Bob Blanchette replied to Dan Wise's discussion Convert BTU/hr in a Manual J to actual fuel usages
"The issues is you size for PEAK, not AVERAGE conditions. This will vary by location, some areas have more constant weather than others. I have NEVER seen a heating system that was too small to do the job, I have seen MANY that are 3X the required…"
Jun 14
eric anderson replied to Dan Wise's discussion Convert BTU/hr in a Manual J to actual fuel usages
"Dan, As a ballpark figure, take the design heat loss and divide by design temp difference, this gives you btu’s per °F per hour.  Multiply this number by 24 hours (per day) and then multiply by heating degree days to get yearly …"
Jun 13
Dan Wise's discussion was featured

Convert BTU/hr in a Manual J to actual fuel usages

I cannot find any conversion table that translates the BTU/hr heat loss in a Manual J report to the amount of fuel required to heat the building to the design temperature.  In this case I'm using propane and I have calculated the 92,000 BTU/gal using the actual BTU/Hr X Degree Days and end up requiring over 30K gallons of propane for a heating system.  This cannot be correct.  Any guidance would be greatly appreciated.See More
Jun 10
Bud Poll replied to Dan Wise's discussion Convert BTU/hr in a Manual J to actual fuel usages
"If 51,000 is your actual heat loss at the design temperature then you need a system capacity of 51,000 BTUs running continuously to maintain the set temperature.  A 60,000 BTU boiler running at 95% efficiency would just barely keep up. …"
Jun 10
Dan Wise replied to Dan Wise's discussion Convert BTU/hr in a Manual J to actual fuel usages
"Hi Bud,  My total heat loss per hour is 51,000 BTU/Hr with a design temperature difference of 48 degrees.  I am using 3900 degree days to figure the heating requirements.   Thanks for any guidance you may provide. Thanks,  Dan"
Jun 10
Bud Poll replied to Dan Wise's discussion Convert BTU/hr in a Manual J to actual fuel usages
"Hi Dan, That would be close to correct if every day was at the design temperature.  I don't use Manual J, so tell me what you have for the design temperature heat loss per hour and then the total heat loss per year at your local HDD. Bud"
Jun 9
Dan Wise posted a discussion

Convert BTU/hr in a Manual J to actual fuel usages

I cannot find any conversion table that translates the BTU/hr heat loss in a Manual J report to the amount of fuel required to heat the building to the design temperature.  In this case I'm using propane and I have calculated the 92,000 BTU/gal using the actual BTU/Hr X Degree Days and end up requiring over 30K gallons of propane for a heating system.  This cannot be correct.  Any guidance would be greatly appreciated.See More
Jun 9

Profile Information

Company
Grand Design Group
Professional Certification
CGP
Professional Interests
National Green Building Standard consulting and verification services.
Construction Management and Project Planning
Website URL
http://www.granddesigngroup.us

Comment Wall (1 comment)

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

At 1:32pm on June 29, 2014, Diane Chojnowski said…

Welcome to Home Energy Pros! Feel free to join the conversation in the Forum and Groups. And share your energy efficiency photos, videos and upcoming events. If you're blogging about home performance, this is the place for you!

Don't forget to add your profile photo and be sure to put your location on our Member Map!


Thanks!
Diane, HEP Moderator

 
 
 

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.

Latest Activity

Hal Skinner replied to Hal Skinner's discussion How our ceramic based RCC works in the group Radiant Control Coatings
"Hey Tom, I will find the ORNL repoprt and post it.  It was a test on a ballasted roof sample.…"
5 hours ago
Tom Mallard replied to Hal Skinner's discussion How our ceramic based RCC works in the group Radiant Control Coatings
"So it seems that what you're saying is for heat-transfer the stuff has little resistance or…"
6 hours ago
Hal Skinner added a discussion to the group Radiant Control Coatings
Thumbnail

How our ceramic based RCC works

How our RCC worksEveryone knows, understands and accepts that RCCs reflect heat away from roofs,…See More
7 hours ago
Mike Kandel posted a discussion

Earn BPI CEUs at 3rd Annual Building Performance Forum

If you're searching for BPI CEUs, you'll find plenty at the 3rd Annual Building Performance Forum…See More
12 hours ago
Mike Kandel added a discussion to the group Building Performance Institute (BPI)
Thumbnail

Earn BPI CEUs at 3rd Annual Building Performance Forum

If you're searching for BPI CEUs, you'll find plenty at the 3rd Annual Building Performance Forum…See More
12 hours ago
Sean Lintow Sr commented on Christopher Morin's blog post UPDATED: Big Changes for Duct Testing in MA
"4% TOTAL Ted - Leakage to outside was stripped from the codes & for good reason"
15 hours ago
tedkidd commented on Christopher Morin's blog post UPDATED: Big Changes for Duct Testing in MA
"Wait!  4% total leakage or 4% leakage to outdoors? "
16 hours ago
Tom White's video was featured

Alliant Energy's PowerHouse TV: Sealing Leaky Ductwork

The PowerHouse television shows are written and produced by Alliant Energy, an energy services company based in Madison, Wis. The first PowerHouse episode was aired in September 1996 on KCRG-TV9 in Cedar Rapids, Iowa, and appears in six broadcast…
18 hours ago

© 2014   Created by Lawrence Berkeley National Laboratory.

Badges  |  Report an Issue  |  Terms of Service