Convert BTU/hr in a Manual J to actual fuel usages

Started this discussion. Last reply by eric anderson Jun 19, 2014. 13 Replies

I cannot find any conversion table that translates the BTU/hr heat loss in a Manual J report to the amount of fuel required to heat the building to the design temperature.  In this case I'm using…Continue

 

Dan Wise's Page

Latest Activity

Diane Chojnowski left a comment for Dan Wise
"Welcome to Home Energy Pros! Feel free to join the conversation in the Forum and Groups. And share your energy efficiency photos, videos and upcoming events. If you're blogging about home performance, this is the place for you! Don't…"
Jun 29, 2014
eric anderson replied to Dan Wise's discussion Convert BTU/hr in a Manual J to actual fuel usages
"Morgan, From the perspective of the energy auditor, I don’t agree with that statement. “Actual fuel and electrical usage" is anecdotal at best” Unless you change something, the best predictor of future energy usage is past…"
Jun 19, 2014
Morgan M Audetat replied to Dan Wise's discussion Convert BTU/hr in a Manual J to actual fuel usages
""Actual fuel and electrical usage" is anecdotal at best. Bin is the thing and ASHRAE/Manual 'J' have the average weather data relevant to the building site.  The operate can cheat the numbers to add what ever he likes, but…"
Jun 18, 2014
eric anderson replied to Dan Wise's discussion Convert BTU/hr in a Manual J to actual fuel usages
"Bud, I think these 2 articles will help illustrate the difficulties of modeling energy usage. http://www.nrel.gov/docs/fy11osti/51603.pdf http://www.sustainablybuilt.com/SB_Modeling_Software_Presentation.pdf The first speaks to the common …"
Jun 18, 2014
Bud Poll replied to Dan Wise's discussion Convert BTU/hr in a Manual J to actual fuel usages
"Hi Morgan, I have admitted my lack of knowledge concerning Manual J and even worse, I approach heat loss from an energy auditor perspective, somewhat different from the HVAC approach. Example, we have no need to break down heat loss to room by room…"
Jun 17, 2014
Morgan M Audetat replied to Dan Wise's discussion Convert BTU/hr in a Manual J to actual fuel usages
"I use Wrightsoft to design HVAC systems, which is base on ACCA Manual 'J' heat load data.  My experience over the last 40 years has not been that over-sizing results from people depending on any Manual 'J' calculation…"
Jun 17, 2014
Bud Poll replied to Dan Wise's discussion Convert BTU/hr in a Manual J to actual fuel usages
"Hi again, Just to be clear, I wasn't questioning the person who did the MJ work, but I was questioning MJ itself as I do not know if or where those factors mentioned are included. There's another distinction between loss at design temp and…"
Jun 15, 2014
eric anderson replied to Dan Wise's discussion Convert BTU/hr in a Manual J to actual fuel usages
"Bud, The question was how to translate- from design heat loss calculated by using  ACCA manual J protocol to a yearly fuel usage.   I outlined a crude way to do it.  Is it perfect? Nope.  There are a lot of caveats to…"
Jun 15, 2014
Bud Poll replied to Dan Wise's discussion Convert BTU/hr in a Manual J to actual fuel usages
"Hi eric, Before we can reverse engineer that peak heat loss number from the manual J (MJ) report we need to know what they included when calculating it.  MJ is noted for over-estimating the appliance size, so has the 51,000 btus/hr number…"
Jun 15, 2014
Bob Blanchette replied to Dan Wise's discussion Convert BTU/hr in a Manual J to actual fuel usages
"The issues is you size for PEAK, not AVERAGE conditions. This will vary by location, some areas have more constant weather than others. I have NEVER seen a heating system that was too small to do the job, I have seen MANY that are 3X the required…"
Jun 14, 2014
eric anderson replied to Dan Wise's discussion Convert BTU/hr in a Manual J to actual fuel usages
"Dan, As a ballpark figure, take the design heat loss and divide by design temp difference, this gives you btu’s per °F per hour.  Multiply this number by 24 hours (per day) and then multiply by heating degree days to get yearly …"
Jun 13, 2014
Dan Wise's discussion was featured

Convert BTU/hr in a Manual J to actual fuel usages

I cannot find any conversion table that translates the BTU/hr heat loss in a Manual J report to the amount of fuel required to heat the building to the design temperature.  In this case I'm using propane and I have calculated the 92,000 BTU/gal using the actual BTU/Hr X Degree Days and end up requiring over 30K gallons of propane for a heating system.  This cannot be correct.  Any guidance would be greatly appreciated.See More
Jun 10, 2014
Bud Poll replied to Dan Wise's discussion Convert BTU/hr in a Manual J to actual fuel usages
"If 51,000 is your actual heat loss at the design temperature then you need a system capacity of 51,000 BTUs running continuously to maintain the set temperature.  A 60,000 BTU boiler running at 95% efficiency would just barely keep up. …"
Jun 10, 2014
Dan Wise replied to Dan Wise's discussion Convert BTU/hr in a Manual J to actual fuel usages
"Hi Bud,  My total heat loss per hour is 51,000 BTU/Hr with a design temperature difference of 48 degrees.  I am using 3900 degree days to figure the heating requirements.   Thanks for any guidance you may provide. Thanks,  Dan"
Jun 10, 2014
Bud Poll replied to Dan Wise's discussion Convert BTU/hr in a Manual J to actual fuel usages
"Hi Dan, That would be close to correct if every day was at the design temperature.  I don't use Manual J, so tell me what you have for the design temperature heat loss per hour and then the total heat loss per year at your local HDD. Bud"
Jun 9, 2014
Dan Wise posted a discussion

Convert BTU/hr in a Manual J to actual fuel usages

I cannot find any conversion table that translates the BTU/hr heat loss in a Manual J report to the amount of fuel required to heat the building to the design temperature.  In this case I'm using propane and I have calculated the 92,000 BTU/gal using the actual BTU/Hr X Degree Days and end up requiring over 30K gallons of propane for a heating system.  This cannot be correct.  Any guidance would be greatly appreciated.See More
Jun 9, 2014

Profile Information

Company
Grand Design Group
Professional Certification
CGP
Professional Interests
National Green Building Standard consulting and verification services.
Construction Management and Project Planning
Website URL
http://www.granddesigngroup.us

Comment Wall (1 comment)

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

At 1:32pm on June 29, 2014, Diane Chojnowski said…

Welcome to Home Energy Pros! Feel free to join the conversation in the Forum and Groups. And share your energy efficiency photos, videos and upcoming events. If you're blogging about home performance, this is the place for you!

Don't forget to add your profile photo and be sure to put your location on our Member Map!


Thanks!
Diane, HEP Moderator

 
 
 

Featured Forum Discussions

Too many BTU's. Too much horsepower?

Started by Steve in General Forum. Last reply by Eric Kjelshus on Saturday. 4 Replies

Stack/wind pressure and flow networks.

Started by Daniel James Grundy in Training. Last reply by Daniel James Grundy Mar 23. 5 Replies

BDT with vermiculite in hollow CMU walls?

Started by Brad Cook in General Forum. Last reply by John Nicholas Mar 23. 2 Replies

Videos

  • Add Videos
  • View All

Latest Activity

Diane Chojnowski posted events
6 minutes ago
Jill Lindman's event was featured

High Performance Mechanicals for Houses That Work at Tacoma Power

May 25, 2017 from 8:30am to 4:30pm
High Performance Mechanical Systems for Houses That Work is a mid-level, full day seminar geared…See More
9 minutes ago
Diane Chojnowski's event was featured
Thumbnail

The Better Buildings Summit at Washington, DC

May 15, 2017 to May 17, 2017
THE BETTER BUILDINGS SUMMITMay 15 -17, 2017 Washington, D.C.AMO’s …See More
11 minutes ago
Home Energy Magazine's 2 videos were featured
38 minutes ago
Sy Richardson's video was featured

Energy Efficient Roofing & 200 MPH Wind Rated

EternaTile delivers the easiest roof to install while delivering energy efficiency, aesthetics and up to 200 MPH sustained wind resistance. Watch how easy it is to install an EternaTile roof.
42 minutes ago
Gary Reed is now a member of Home Energy Pros
3 hours ago
Sy Richardson posted a video

Energy Efficient Roofing & 200 MPH Wind Rated

EternaTile delivers the easiest roof to install while delivering energy efficiency, aesthetics and up to 200 MPH sustained wind resistance. Watch how easy it is to install an EternaTile roof.
5 hours ago
Jacob Corvidae commented on Home Energy Magazine's blog post The Elephant in the Room
"Great story, Jim (and Kara).  For anyone interested in training on engaging with…"
6 hours ago

Home Energy Pros

Welcome to Home Energy Pros – the unique digital community by and for those who work in the home energy performance arena.

Home Energy Pros was founded by the developers of Home Energy Saver Pro (supported by the U.S. Department of Energy) and brought to you in partnership with Home Energy magazine.  Home Energy Pros is sponsored by the Better Buildings Residential Network. Please honor our Guidelines

© 2017   Created by Lawrence Berkeley National Laboratory.   Powered by

Badges  |  Report an Issue  |  Terms of Service