Damien Herold
  • Cincinnati, OH
  • United States
Share on Facebook Share on Facebook Share

Damien Herold's Groups

Damien Herold's Discussions

Free Energy Audit Sales Flyer / Brochures
1 Reply

copy and paste this for your web browser  http://www.marylandenergyauditor.com/home-energy-audit-brochures.htmlContinue

Started this discussion. Last reply by Damien Herold Mar 15, 2013.

Tired of climbing ladders and reaching to find air leaks during blower door test I have a solution!!!
17 Replies

Yes, a thermal image camera is a good way, but a better way to instantly see the leak and the cfm amount of the leak-- try using the Alnor thermoanemometer Model 8565.    Cheap on ebay for $100. Plus…Continue

Tags: testing, door, blower, sealing, air

Started this discussion. Last reply by Damien Herold Nov 26, 2012.

$ 250 for BPI exam, $ 500 for field exam !
3 Replies

BPI as of FEB 1st will raise their fees for exam and yearly renewals to $ 250.00, and field exams to $ 500.00. A bit tooo much?  Any comments?Continue

Started this discussion. Last reply by Bud Poll Feb 3, 2012.

Duct Testing
2 Replies

When using the Duct Blaster I have found it necessary to seal the combustion air grilles on the furnace door and flue on an 80% afue gas furnace in order to obtain accurate leakage results. Any…Continue

Started this discussion. Last reply by Sean Lintow Sr Jan 28, 2012.

 

Damien Herold's Page

Latest Activity

Damien Herold joined allen p tanner's group
Thumbnail

Energy Auditing Equipment for Sale, Trade or to Purchase

Discuss the pros and cons of the equipment you are interested in prior to purchase. Post equipment you have to sell, trade or wish to purchase.Please post the equipment age, serial numbers, condition, warranties and asking price.See More
Jul 8, 2014
Damien Herold replied to Damien Herold's discussion Free Energy Audit Sales Flyer / Brochures
"great advertising materials   its about time"
Mar 15, 2013
Damien Herold posted a discussion
Mar 15, 2013
Damien Herold replied to Damien Herold's discussion Tired of climbing ladders and reaching to find air leaks during blower door test I have a solution!!!
"Check ebay now, there is one for $ 100.00. Thermoanemanometer measures velocity in fpm, and with a simple calculation you can convert to cfm."
Nov 26, 2012
Damien Herold replied to Damien Herold's discussion Tired of climbing ladders and reaching to find air leaks during blower door test I have a solution!!!
"Hello Glen, I would never work for anyone but my valued customers. My customers love me and all my business comes from word of mouth. By the way, you can use your smoker if you want. Not me."
Nov 26, 2012
Glen Gallo replied to Damien Herold's discussion Tired of climbing ladders and reaching to find air leaks during blower door test I have a solution!!!
"Damien I would not allow the figure in a report if you worked for me.Nor would I let you covey that information to a client. I think the tool is useful just not in the manner you use it "
Nov 26, 2012
Damien Herold replied to Damien Herold's discussion Tired of climbing ladders and reaching to find air leaks during blower door test I have a solution!!!
"Along side of a fireplace with an 11 foot ceiling which has a .25 inch opening along the outer edge. Dave, it is simple math. 9 cfm total at 450 fpm."
Nov 23, 2012
Damien Herold replied to Damien Herold's discussion Tired of climbing ladders and reaching to find air leaks during blower door test I have a solution!!!
"Along side of a fireplace with an 11 foot ceiling which has a .25 inch opening along the outer edge. Glen it is simple math. 9 cfm total at 450 fpm."
Nov 23, 2012
Jack Baikoff replied to Damien Herold's discussion Tired of climbing ladders and reaching to find air leaks during blower door test I have a solution!!!
"It seems like not only the features and the uses of the device seem to be overstated, but also the price is under-estimated. It seems to be closer to $300 on eBay. "
Nov 12, 2012
Glen Gallo replied to Damien Herold's discussion Tired of climbing ladders and reaching to find air leaks during blower door test I have a solution!!!
"After looking it up I see that it reads temperature of the probe at a set figure. It reads based on how much it cools down and displays that into data. no flow equals no cool down  It does not read pressure at all. Very cool device. Still…"
Oct 1, 2012
David Meiland replied to Damien Herold's discussion Tired of climbing ladders and reaching to find air leaks during blower door test I have a solution!!!
"It doesn't work like you apparently think it does. Yes, the anemometer head gives you feet per minute of airflow (or some other velocity measurement), but to convert that velocity into a cubic footage measurement you need an exact measurement…"
Sep 29, 2012
Glen Gallo replied to Damien Herold's discussion Tired of climbing ladders and reaching to find air leaks during blower door test I have a solution!!!
"I don't get how this would work for a BD test. The instrument seems to be designed for using in a duct. As it is testing air flow or realistically pressure and converting that number how are these…"
Sep 29, 2012
Bob Kretvix replied to Damien Herold's discussion Tired of climbing ladders and reaching to find air leaks during blower door test I have a solution!!!
"You can also get types where you plug in the dimensions and it gives readings in cfm. "
Sep 28, 2012
Damien Herold replied to Damien Herold's discussion Tired of climbing ladders and reaching to find air leaks during blower door test I have a solution!!!
"Hi Tammy,  The device gives you FPM, which is converted to CFM by multipling FPM by the area and dividing by 144."
Sep 28, 2012
Tammy Kenworthy replied to Damien Herold's discussion Tired of climbing ladders and reaching to find air leaks during blower door test I have a solution!!!
"does the device have a read out display that shows the CFM #? -Tammy    ilovewaterheaters.com "
Sep 28, 2012
Damien Herold replied to Damien Herold's discussion Tired of climbing ladders and reaching to find air leaks during blower door test I have a solution!!!
"If you have a 300 square foot bedroom, and the cfm is under 400 (roughly) the room becomes a low priority. Also, the Alnor works great around windows especially when the sun is out ( which plays havoc with IR) and windows treatments are present, you…"
Sep 28, 2012

Profile Information

Company
Global Comfort
Professional Certification
Master HVAC
Website URL
http://www.globalcomfort.org

Damien Herold's Photos

Loading…
  • Add Photos
  • View All

Comment Wall (1 comment)

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

At 2:33pm on May 7, 2011, Diane Chojnowski said…

Welcome to Home Energy Pros! Feel free to join the conversation in the Forum and Groups. And share your energy efficiency photos, videos and upcoming events. If you're blogging about home performance, this is the place for you!

Don't forget to upload your profile photo. And add your location on our Member Map!


Thanks!
Diane, HEP Moderator

 
 
 

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.

Latest Activity

John Nicholas replied to William Fisher's discussion Can tankless water heaters provide hot water even when the groundwater is fairly cold?
"No,  I don't heat my toilet water, but I don't like being in the shower when someone…"
2 hours ago
R Higgins replied to William Fisher's discussion Can tankless water heaters provide hot water even when the groundwater is fairly cold?
"Hi John Love your attention to detail, too many base decisions on 'what they've…"
4 hours ago
Al Heath replied to Bryan Pringle's discussion Dense packed cellulose in basement?
"My favorite was 2x4 directly on cement basement wall, with fiberglass, then plastic inside of…"
10 hours ago
John Nicholas replied to William Fisher's discussion Can tankless water heaters provide hot water even when the groundwater is fairly cold?
"Simple math will tell you.   Figure the GPM requirements for each fixture you think will run…"
12 hours ago
R Higgins replied to William Fisher's discussion Can tankless water heaters provide hot water even when the groundwater is fairly cold?
"I have that problem, 45 to 50 degree ground water, in summer, not that we have much of a…"
20 hours ago
R Higgins replied to Larry Schaffert's discussion How to correctly insulate exterior wall in a 1900 house?
"I'd suggest trying to replicate the existing conditions as much as possible in your rebuild,…"
21 hours ago
Bryan Pringle replied to Bryan Pringle's discussion Dense packed cellulose in basement?
"I am getting a lot of "bad idea" push back on this.  I fully understand that…"
yesterday
Greg Mitchell commented on Larry Ralph Jr's blog post Top 7 Worst Crawl Space Repairs
"Spray Foam should be used in crawlspaces.   To learn about closed cell foam in crawlspaces…"
yesterday